4. Freezers – Energy Saving Operating Mode
a) Sequence of Operation
| POWER ON |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Board Self Check |
|
|
|
| ||||
1. | Frame heater(s) on |
|
| 1. | Compressor |
| ||
|
|
| ||||||
2. | Evaporator fan(s) |
|
| 2. | Condenser fan |
| ||
| cycles on and off |
|
| 3. | Evaporator fan(s) on |
| ||
|
|
|
|
|
|
| (continuously) |
|
|
|
|
|
|
|
|
|
|
Cycle Off
1.Compressor off
2.Condenser fan off
3.Evaporator fan(s) cycles on and off
Cycle On
1.Compressor
2.Condenser fan
3.Evaporator fan(s) on (continuously)
Continue as normal cycling
Defrost Start Preprogrammed time interval
1.Compressor off
2.Evaporator fan(s) off
3.Condenser fan off
4.Defrost heater on
5. "dF" displayed
Defrost End Defrost thermistor reaches defrost termination temperature,
or defrost timer reaches 1 hour
Defrost heater off
Five minutes after defrost heater off
1.Compressor on
2.Condenser fan on
Five minutes after |
|
| Eight minutes after evaporator |
compressor |
|
| fan |
|
| ||
1. Evaporator fan(s) on |
|
| displayed, cabinet temperature |
|
|
| displayed |
| |||
|
|
|
|
Note:
1)
2)The defrost thermistor reads the evaporator temperature.
19