Problem | Possible Cause |
| Remedy | |
[5] | Cabinet | a)Setpoint and/or | 1. Incorrect. | 1. Correct setting(s). |
| temperature too | Differential |
| See sections "II.D.2.b)" and |
| high. |
|
| "II.D.3.c)" for defaults. |
|
| b)Door | 1. Not sealing, opened | 1. Check for sealing, check for |
|
|
| frequently or open for | door open at time of warm |
|
|
| long intervals. | cabinet temperature. |
|
| c) Defrost | 1. Defrost time | 1. See "[8] Evaporator does |
|
|
| insufficient to remove | not defrost completely." |
|
|
| frost. |
|
|
|
| Operation in humid |
|
|
|
| conditions. |
|
|
| d)Refrigerant | 1. Leak. | 1. Repair leak and recharge. |
|
| e)Fan Motor | 1. Defective. | 1. Check and replace. |
|
| f) Air Filter | 1. Clogged. | 1. Clean. |
|
| g)Condenser | 1. Dirty. | 1. Clean. |
|
| h)Thermistor | 1. Defective. | 1. Check and replace. |
|
|
|
|
|
|
| i) Control Board | 1. Defective. | 1. Replace. |
|
| j) Outside Heat Source | 1. Too close to unit. | 1. Separate unit from heat |
|
|
|
| source. |
|
| k) Air Flow | 1. Blockage inside | 1. Remove blocakge by removing |
|
|
| interior. | or redistributing food product. |
|
| l) Warm Food | 1. Warm food recently | 1. Allow time for unit to return to |
|
|
| placed in refrigerator. | setpoint temperature. |
[6] | Cabinet | a)Power Supply | 1. "OFF" position. | 1. Move to "ON" position. |
| temperature |
| 2. Loose connection(s). | 2. Tighten or reconnect. |
| display |
|
|
|
|
| 3. Failure or tripped | 3. Call electrician and/or reset | |
| indicator does |
| ||
|
| breaker. | breaker. | |
| not illuminate |
| ||
| b)Control Board | 1. Defective. | 1. Replace. | |
| properly. | |||
|
|
|
| |
[7] | Cabinet | a)Setpoint and/or | 1. Incorrect. | 1. Correct setting(s). |
| temperature too | Differential |
| See sections "II.D.2.b)" and |
| low. |
|
| "II.D.3.c)" for defaults. |
|
| b)Frozen Food | 1. Frozen food recently | 1. Allow time for unit to return to |
|
|
| placed in refrigerator. | setpoint temperature. |
|
| c) Thermistor | 1. Defective. | 1. Check and replace. |
|
| d)Compressor Relay | 1. Defective; contacts | 1. Replace. |
|
|
| welded. |
|
|
| e)Control Board | 1. Defective. | 1. Replace. |
[8] | Evaporator does | a)Defrost Thermistor | 1. Defective. | 1. Check and replace. |
| not defrost | b)Defrost | 1. Not enough defrosts | 1. Factory default is once every |
| completely. |
| occurring per day. | 6 hours. If coil is frosting too |
|
|
| Operation in humid | much, can shorten defrost |
|
|
| conditions. | interval. |
|
| c) Defrost Heaters | 1. Defective. | 1. Replace heaters. |
|
| d)Safety Defrost | 1. Defective, turning off | 1. Replace safety defrost |
|
| Thermostat | heaters prematurely, | thermostat. |
|
|
| or fused open. |
|
|
| e)Defrost Heater | 1. Blown. | 1. Determine why fuse blew. |
|
| Temperature Fuse |
| Replace fuse. |
43