3. Settings and Diagnostics Menu
To gain access to the settings, see "II.D.1. Gaining Access to Settings and Diagnostics." Once inside this menu, press the MANUAL DEFROST button to scroll through the menu
and the unmarked, blank button at any point to view the current setting. Press the MANUAL DEFROST button to return to the menu screen.
|
|
|
| Default |
|
| |
|
|
| Refrigerator | Freezer | |||
|
|
| Auxiliary Code |
|
|
| |
|
|
| Q5 and | Q6 and | 1 |
| 2 |
Code | Item | Setting and Display Range | earlier | later | section |
| section |
F0 | Defrost Interval | 1 to 12 hours in 1 hour increments | 6 | 6 |
| 6 | |
F1 | Defrost Termination | Refrigerator: 59 to 68°F (15 to 20°C) in |
|
|
|
|
|
| Temperature | one degree increments | 59°F | 59°F | 41°F | ||
|
| Freezer: 41 to 68°F (5 to 20°C) in one |
|
|
|
|
|
|
| degree increments |
|
|
|
|
|
F2 | Setpoint | 0 to 6.3°F in increments of .9°F | 0°F, | 0°F, | 0°F, | 0°F, | |
| Temperature | (0 to 3.5°C in increments of .5°C) | (0°C, | (2.0, - | (0°C, |
| (2.0, |
| Differential |
| 2.0°C) |
| |||
| (upper and lower) |
| (decimal | (decimal | (decimal |
| (decimal |
|
|
| is not | is not | is not |
| is not |
|
|
| displayed) | displayed) | displayed) |
| displayed) |
F3 | High Temperature | 0 to 180 minutes in 60 minute |
|
|
|
|
|
| Alarm Delay Time | increments | 2 | 2 |
| 2 | |
|
| (0=0; 1=60; 2=120; 3=180 minutes) |
|
|
|
|
|
F4 | Low Temperature | 0 or 60 minutes | 1 | 1 |
| 1 | |
| Alarm Delay Time | (0=0; 1=60 minutes) |
| ||||
|
|
|
|
|
| ||
F5 | Temperature Dis- | Fahrenheit or Celsius | °F | °F | °F | ||
| play |
| |||||
|
|
|
|
|
|
| |
F6 | Alarm History | Displays alarm history - maximum 8 | NA | NA | NA | ||
|
| alarms | |||||
|
|
|
|
|
|
| |
F7 | Compressor Run | Displays run time between two most | NA | NA | NA | ||
| Time | recent defrosts | |||||
|
|
|
|
|
| ||
F8 | Not Used |
| NA | NA | NA | ||
F9 | Not Used |
| NA | NA | NA |
26