Miele G 7883 CD installation instructions Important Safety Instructions

Page 5
IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

This machine conforms to current safety requirements. However, inappropriate use can lead to personal injury and property damage. Read the operating instructions carefully before using this machine.

The manufacturer cannot be held responsible for damage caused by non-observance of these Important Safety Instructions.

WARNING - To reduce the risk of fire, electric shock or injury:

Use

~This machine is not intended for any purpose that is not indicated in the operating instructions. Conversions, modifications, and other unintended uses are considered to be dangerous. The cleaning processes described here apply only to those medical products that are specifically designed by the manufacturer to be re-used. Follow the product manufacturer's instructions. Miele will not be held liable for damage caused by incorrect use of any kind.

~The installation of this unit in non stationary locations (e.g. ships) must be performed by a qualified installer or service agency in strict accordance with national and local safety regulations and standards.

Please pay attention to the following notes to maintain safe procedures.

~The machine should be installed, commissioned and maintained only by a Miele Service Technician. Repairs by unqualified persons could be dangerous.

~Do not install the machine in an area where a danger of explosion or freezing may be present.

~Be certain this appliance is properly installed and grounded by an authorized technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system checked by a qualified technician. The manufacturer cannot be held responsible for damage or injury caused by the lack, or inadequacy, of an effective grounding system

(e.g. electric shock).

~A damaged machine is dangerous. Turn off the machine immediately at the main switch and call the Miele Service Department.

~Personnel operating the machine should be trained regularly. Children and untrained personnel must not be allowed access to the machine or its controls.

5

Image 5
Contents en - US, CA Operating and Installation InstructionsLaboratory Glassware Washer G 7883 CD Page Contents Program Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Programming functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 The following instructions apply to all programming functions:. . . . . . . . . . . . . . . 36 To access the programming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Saving to memory and exiting the programming mode . . . . . . . . . . . . . . . . . . 36 Exiting the programming mode without saving . . . . . . . . . . . . . . . . . . . . . . . . 36 DOS 1 liquid detergent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Setting the detergent dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 DOS 3 neutralizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Setting the neutralizer dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Changing program parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Changing the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Changing the holding time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Restoring the factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Setting the time and date. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Resetting the coarse and fine filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Data transfer optional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Routine checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Frequently asked questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Thermo switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPORTANT SAFETY INSTRUCTIONS ~Take care when handling processing chemicals detergents, softeners, neutralizers, etc.. These may contain irritant or corrosive ingredients. Do not use organic solvents as these could cause an explosion. Wear protective gloves and goggles. With all chemical agents the manufacturer’s safety conditions must be observed IMPORTANT SAFETY INSTRUCTIONS Accessories Please note the following symbols on the machineSAVE THESE INSTRUCTIONS Disposal of an old applianceGuide to the lab washer a Drying unit h Service panel i Serial interfacec Dispenser for powdered detergent d Rinse aid reservoir with dosage selectorIntended applications: Laboratory equipment Description of the machineStandard model Electric door lock Opening and closing the doorTo open the door To close the doorWater softener Setting the water softenerfactory setting SettingsFilling the salt reservoir Salt indicator Adding rinse aid Rinse AidSetting the rinse aid dosage Rinse aid indicator lightAdding neutralizer Neutralizing agentNeutralizer indicator light Adding detergent Setting the liquid detergent dosageDetergent Liquid detergent refill light ^Snap the cover closed ^Load the detergent into the compartmentLoading the machine Special preparations before operating the machine Loading the machinePrepare items before loading To adjust the upper basket Adjusting the upper basketSpring adapter for the water connection Laboratory equipment Lower basket U Upper basket OFor various inserts O Injector wagon E Injector wagonFor narrow necked glassware Upper basket For direct injection ofSelecting the optional drying function Turning onStarting a program Program sequence display Additional drying End of a programTurning off Canceling a program Program Guide Program sequence To access the programming mode Programming functionsGeneral information Saving to memory and exiting the programming modeSetting the detergent dosage DOS 1 liquid detergentStep Display / ResultSetting the neutralizer dosage DOS 3 neutralizerBuzzer Changing the drying parameters Changing program parametersChanging the wash and rinse parameters Changing the holding time Step Changing the temperature StepRestoring the factory settings Setting the time and date Resetting the coarse and fine filter timer Data transfer optional Routine checks MaintenanceCleaning the filters in the wash cabinet Cleaning and CareCleaning the fine, flat and micro-finefilters Removing the spray arms Cleaning the spray armsCleaning the drain pump and non-returnvalve Cleaning the filters Cleaning the water inlet filtersCleaning the exterior Cleaning the control panelCleaning the wash cabinet Cleaning the door sealBaskets and inserts Possible fault Frequently asked questionsSolution What ifWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if show signs of Items made of glasscorrosion Items made of stainlesson the labware There are whitedeposits and/or spots unacceptable The wash result isThermo switch U1-800-991-9380techserv@mieleusa.com After Sales ServiceV1-800-565-6435service@miele.ca INSTALLATION INSTRUCTIONS Positioning and securing the machine InstallationLeveling the legs Cover plate protects the countertop Removing the lid if necessaryProtecting the countertop Grounding connection Electrical connectionTHIS APPLIANCE MUST BE GROUNDED Plumbing Connecting the water inletPlease also refer to the installation diagram DI connection unpressurized optional DI Connection pressurizedDrainage Metric Technical dataEnglish Disposal of an old appliance Caring for the environmentDisposal of the packing materials Page M.-Nr.07 157 440 / Subject to change without notice /