Miele G 7883 CD Cleaning the control panel, Cleaning the exterior, Cleaning the wash cabinet

Page 52
Cleaning the control panel

Cleaning and Care

Cleaning the control panel

^The control panel should only be cleaned with a damp cloth or a suitable cleaner for use on plastic materials.

,Do not use abrasive cleaners, glass cleaners or all-purpose cleaners! They will damage the control panel.

Cleaning the exterior

^Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner or dishwashing detergent and warm water.

^To help prevent resoiling, a conditioner for stainless steel can also be used. Apply sparingly with even pressure.

,Do not use cleaners containing thinner or ammonia. They will damage the surface.

,Never clean the machine or near its vicinity with a water or high pressure hose.

Cleaning the wash cabinet

The wash cabinet is mostly self cleaning.

If deposits have built, contact Miele for info.

Cleaning the door seal

Clean the door seal regularly with a damp cloth to remove soiling.

To replace damaged or leaking door seals please contact Miele's Technical Service Dept.

Dispensing systems

Check the consumption of the used chemicals regularly to notice any irregularities of the dispensing.

52

Image 52
Contents Laboratory Glassware Washer G 7883 CD Operating and Installation Instructionsen - US, CA Page Contents Program Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Programming functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 The following instructions apply to all programming functions:. . . . . . . . . . . . . . . 36 To access the programming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Saving to memory and exiting the programming mode . . . . . . . . . . . . . . . . . . 36 Exiting the programming mode without saving . . . . . . . . . . . . . . . . . . . . . . . . 36 DOS 1 liquid detergent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Setting the detergent dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 DOS 3 neutralizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Setting the neutralizer dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Changing program parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Changing the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Changing the holding time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Restoring the factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Setting the time and date. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Resetting the coarse and fine filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Data transfer optional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Routine checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Frequently asked questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Thermo switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPORTANT SAFETY INSTRUCTIONS ~Take care when handling processing chemicals detergents, softeners, neutralizers, etc.. These may contain irritant or corrosive ingredients. Do not use organic solvents as these could cause an explosion. Wear protective gloves and goggles. With all chemical agents the manufacturer’s safety conditions must be observed IMPORTANT SAFETY INSTRUCTIONS Please note the following symbols on the machine AccessoriesSAVE THESE INSTRUCTIONS Disposal of an old applianceGuide to the lab washer h Service panel i Serial interface a Drying unitc Dispenser for powdered detergent d Rinse aid reservoir with dosage selectorStandard model Description of the machineIntended applications: Laboratory equipment Opening and closing the door Electric door lockTo open the door To close the doorSetting the water softener Water softenerSettings factory settingFilling the salt reservoir Salt indicator Rinse Aid Adding rinse aidRinse aid indicator light Setting the rinse aid dosageNeutralizing agent Adding neutralizerNeutralizer indicator light Detergent Setting the liquid detergent dosageAdding detergent Liquid detergent refill light ^Load the detergent into the compartment ^Snap the cover closedLoading the machine Prepare items before loading Loading the machineSpecial preparations before operating the machine Spring adapter for the water connection Adjusting the upper basketTo adjust the upper basket Laboratory equipment For various inserts Upper basket OLower basket U E Injector wagon O Injector wagonFor narrow necked glassware Upper basket For direct injection ofStarting a program Turning onSelecting the optional drying function Program sequence display Turning off End of a programAdditional drying Canceling a program Program Guide Program sequence Programming functions To access the programming modeGeneral information Saving to memory and exiting the programming modeDOS 1 liquid detergent Setting the detergent dosageStep Display / ResultDOS 3 neutralizer Setting the neutralizer dosageBuzzer Changing the wash and rinse parameters Changing program parametersChanging the drying parameters Changing the temperature Step Changing the holding time StepRestoring the factory settings Setting the time and date Resetting the coarse and fine filter timer Data transfer optional Maintenance Routine checksCleaning and Care Cleaning the filters in the wash cabinetCleaning the fine, flat and micro-finefilters Cleaning the spray arms Removing the spray armsCleaning the drain pump and non-returnvalve Cleaning the water inlet filters Cleaning the filtersCleaning the control panel Cleaning the exteriorCleaning the wash cabinet Cleaning the door sealBaskets and inserts Frequently asked questions Possible faultSolution What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions Items made of glass show signs ofcorrosion Items made of stainlessdeposits and/or spots There are whiteon the labware The wash result is unacceptableThermo switch V1-800-565-6435service@miele.ca After Sales ServiceU1-800-991-9380techserv@mieleusa.com INSTALLATION INSTRUCTIONS Leveling the legs InstallationPositioning and securing the machine Protecting the countertop Removing the lid if necessaryCover plate protects the countertop THIS APPLIANCE MUST BE GROUNDED Electrical connectionGrounding connection Connecting the water inlet PlumbingPlease also refer to the installation diagram DI Connection pressurized DI connection unpressurized optionalDrainage English Technical dataMetric Disposal of the packing materials Caring for the environmentDisposal of an old appliance Page Subject to change without notice / M.-Nr.07 157 440 /