Miele G 7883 CD Frequently asked questions, What if, Possible fault, Solution, There are white

Page 61
There are white

Frequently asked questions

What if...

Possible fault

Solution

There are white

The water softener setting

Test the tap water

deposits and/or spots

is too low.

hardness and program the

on the labware.

 

water softener according.

 

Too much powder

Be sure you are using the

 

detergent is being used.

correct amount of

 

 

detergent.

 

The neutralizer is not

Check the neutralizer

 

dispensing properly.

dispenser.

 

There is no reactivation

Carefully fill the reservoir

 

salt in the reservoir.

with the reactivation salt.

 

The screw cap on the

Properly thread the cap

 

reactivation salt reservoir is

and screw it tightly.

 

not tightened.

 

 

 

The rinse water quality was

Use water with a lower

 

insufficient.

 

conductivity.

 

 

If the washer is

 

 

 

connected to a

 

 

 

demineralizing

 

 

 

cartridge, check the

 

 

 

status and change as

 

 

 

needed.

61

Image 61
Contents Laboratory Glassware Washer G 7883 CD Operating and Installation Instructionsen - US, CA Page Contents Program Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Programming functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 The following instructions apply to all programming functions:. . . . . . . . . . . . . . . 36 To access the programming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Saving to memory and exiting the programming mode . . . . . . . . . . . . . . . . . . 36 Exiting the programming mode without saving . . . . . . . . . . . . . . . . . . . . . . . . 36 DOS 1 liquid detergent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Setting the detergent dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 DOS 3 neutralizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Setting the neutralizer dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Changing program parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Changing the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Changing the holding time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Restoring the factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Setting the time and date. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Resetting the coarse and fine filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Data transfer optional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Routine checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Frequently asked questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Thermo switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPORTANT SAFETY INSTRUCTIONS ~Take care when handling processing chemicals detergents, softeners, neutralizers, etc.. These may contain irritant or corrosive ingredients. Do not use organic solvents as these could cause an explosion. Wear protective gloves and goggles. With all chemical agents the manufacturer’s safety conditions must be observed IMPORTANT SAFETY INSTRUCTIONS Accessories Please note the following symbols on the machineSAVE THESE INSTRUCTIONS Disposal of an old applianceGuide to the lab washer a Drying unit h Service panel i Serial interfacec Dispenser for powdered detergent d Rinse aid reservoir with dosage selectorStandard model Description of the machineIntended applications: Laboratory equipment Electric door lock Opening and closing the doorTo open the door To close the doorWater softener Setting the water softenerfactory setting SettingsFilling the salt reservoir Salt indicator Adding rinse aid Rinse AidSetting the rinse aid dosage Rinse aid indicator lightAdding neutralizer Neutralizing agentNeutralizer indicator light Detergent Setting the liquid detergent dosageAdding detergent Liquid detergent refill light ^Snap the cover closed ^Load the detergent into the compartmentLoading the machine Prepare items before loading Loading the machineSpecial preparations before operating the machine Spring adapter for the water connection Adjusting the upper basketTo adjust the upper basket Laboratory equipment For various inserts Upper basket OLower basket U O Injector wagon E Injector wagonFor narrow necked glassware Upper basket For direct injection ofStarting a program Turning onSelecting the optional drying function Program sequence display Turning off End of a programAdditional drying Canceling a program Program Guide Program sequence To access the programming mode Programming functionsGeneral information Saving to memory and exiting the programming modeSetting the detergent dosage DOS 1 liquid detergentStep Display / ResultSetting the neutralizer dosage DOS 3 neutralizerBuzzer Changing the wash and rinse parameters Changing program parametersChanging the drying parameters Changing the holding time Step Changing the temperature StepRestoring the factory settings Setting the time and date Resetting the coarse and fine filter timer Data transfer optional Routine checks MaintenanceCleaning the filters in the wash cabinet Cleaning and CareCleaning the fine, flat and micro-finefilters Removing the spray arms Cleaning the spray armsCleaning the drain pump and non-returnvalve Cleaning the filters Cleaning the water inlet filtersCleaning the exterior Cleaning the control panelCleaning the wash cabinet Cleaning the door sealBaskets and inserts Possible fault Frequently asked questionsSolution What ifWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if Frequently asked questionsWhat if show signs of Items made of glasscorrosion Items made of stainlessdeposits and/or spots There are whiteon the labware unacceptable The wash result isThermo switch V1-800-565-6435service@miele.ca After Sales ServiceU1-800-991-9380techserv@mieleusa.com INSTALLATION INSTRUCTIONS Leveling the legs InstallationPositioning and securing the machine Protecting the countertop Removing the lid if necessaryCover plate protects the countertop THIS APPLIANCE MUST BE GROUNDED Electrical connectionGrounding connection Plumbing Connecting the water inletPlease also refer to the installation diagram DI connection unpressurized optional DI Connection pressurizedDrainage English Technical dataMetric Disposal of the packing materials Caring for the environmentDisposal of an old appliance Page M.-Nr.07 157 440 / Subject to change without notice /