Miele G 7883 CD After Sales Service, U1-800-991-9380techserv@mieleusa.com

Page 64
After Sales Service

After Sales Service

In the event of a fault which you cannot correct yourself please contact the Miele Technical Service Department

U1-800-991-9380 techserv@mieleusa.com

V1-800-565-6435 service@miele.ca

^Please quote the model of your machine. This information can be found on the machine’s front panel.

64

Image 64
Contents Laboratory Glassware Washer G 7883 CD Operating and Installation Instructionsen - US, CA Page Contents Program Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Programming functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 The following instructions apply to all programming functions:. . . . . . . . . . . . . . . 36 To access the programming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Saving to memory and exiting the programming mode . . . . . . . . . . . . . . . . . . 36 Exiting the programming mode without saving . . . . . . . . . . . . . . . . . . . . . . . . 36 DOS 1 liquid detergent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Setting the detergent dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 DOS 3 neutralizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Setting the neutralizer dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Priming the dosage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Changing program parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Changing the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Changing the holding time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Restoring the factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Setting the time and date. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Resetting the coarse and fine filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Data transfer optional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Routine checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Frequently asked questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Thermo switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPORTANT SAFETY INSTRUCTIONS ~Take care when handling processing chemicals detergents, softeners, neutralizers, etc.. These may contain irritant or corrosive ingredients. Do not use organic solvents as these could cause an explosion. Wear protective gloves and goggles. With all chemical agents the manufacturer’s safety conditions must be observed IMPORTANT SAFETY INSTRUCTIONS Please note the following symbols on the machine AccessoriesSAVE THESE INSTRUCTIONS Disposal of an old applianceGuide to the lab washer h Service panel i Serial interface a Drying unitc Dispenser for powdered detergent d Rinse aid reservoir with dosage selectorStandard model Description of the machineIntended applications: Laboratory equipment Opening and closing the door Electric door lockTo open the door To close the doorSetting the water softener Water softenerSettings factory settingFilling the salt reservoir Salt indicator Rinse Aid Adding rinse aidRinse aid indicator light Setting the rinse aid dosageNeutralizing agent Adding neutralizerNeutralizer indicator light Detergent Setting the liquid detergent dosageAdding detergent Liquid detergent refill light ^Load the detergent into the compartment ^Snap the cover closedLoading the machine Prepare items before loading Loading the machineSpecial preparations before operating the machine Spring adapter for the water connection Adjusting the upper basketTo adjust the upper basket Laboratory equipment For various inserts Upper basket OLower basket U E Injector wagon O Injector wagonFor narrow necked glassware Upper basket For direct injection ofStarting a program Turning onSelecting the optional drying function Program sequence display Turning off End of a programAdditional drying Canceling a program Program Guide Program sequence Programming functions To access the programming modeGeneral information Saving to memory and exiting the programming modeDOS 1 liquid detergent Setting the detergent dosageStep Display / ResultDOS 3 neutralizer Setting the neutralizer dosageBuzzer Changing the wash and rinse parameters Changing program parametersChanging the drying parameters Changing the temperature Step Changing the holding time StepRestoring the factory settings Setting the time and date Resetting the coarse and fine filter timer Data transfer optional Maintenance Routine checksCleaning and Care Cleaning the filters in the wash cabinetCleaning the fine, flat and micro-finefilters Cleaning the spray arms Removing the spray armsCleaning the drain pump and non-returnvalve Cleaning the water inlet filters Cleaning the filtersCleaning the control panel Cleaning the exteriorCleaning the wash cabinet Cleaning the door sealBaskets and inserts Frequently asked questions Possible faultSolution What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions What ifFrequently asked questions Items made of glass show signs ofcorrosion Items made of stainlessdeposits and/or spots There are whiteon the labware The wash result is unacceptableThermo switch V1-800-565-6435service@miele.ca After Sales ServiceU1-800-991-9380techserv@mieleusa.com INSTALLATION INSTRUCTIONS Leveling the legs InstallationPositioning and securing the machine Protecting the countertop Removing the lid if necessaryCover plate protects the countertop THIS APPLIANCE MUST BE GROUNDED Electrical connectionGrounding connection Connecting the water inlet PlumbingPlease also refer to the installation diagram DI Connection pressurized DI connection unpressurized optionalDrainage English Technical dataMetric Disposal of the packing materials Caring for the environmentDisposal of an old appliance Page Subject to change without notice / M.-Nr.07 157 440 /