Miele KM 81-2 ÖConversion to alternative types of gas, Reference table jet sizes

Page 33

Conversion to alternative types of gas

When converting to alternative types of gas (LP gas) or back to Natural gas, the main jet and the small jets of the burner must be changed.

Turn off the gas main (if this ap- pliance has already been installed), turn off the electrical supply and pull out the plug.

Remove the wok/pan support, the large burner cap, the burner ring and the large burner cap base.

With a philipeshead screwdriver, loosen the three screws.

Pull the controls for the gas burner up and off.

Carefully raise the cooktop cover slightly at the rear and pull forward. Then carefully lift upwards and for- wards. Ensure that the ground lead which connects the cooktop and the control panel is not damaged.

Screw in the new jets following the table. The gas cooktop unit is sup- plied ready equipped for natural gas; the appropriate gas jet kit for cy- linder gas, LPG (Liquefied Petro- leum), is supplied with the appliance.

Reference table - jet sizes

USA/CDN

gas type

burner size

jet

adj.

 

 

 

screw

 

 

 

 

Natural

Small

No. 34

0.40 mm

 

Large

2.0 mm

0.88 mm

 

 

 

 

Propane

Small

No. 7

0.25 mm

 

Large

1.20 mm

0.54 mm

 

 

 

 

33

Image 33
Contents @äö Description of the appliance Stainless steel cover-EA Data plateContents For Canada only For your safetyHelp protect our environment Disposal of packagingDisposal of your old machine Important notes for the installer Important safety instructionsPage Page Save the Instructions Burner control BurnerPower cut Shape of woks, pots and pans MaterialWok / Pan base LidsCleaning and care Burner capsElectronic ignition Wok/pan support, trivet Cooktop surfaceControl panel / Control knob Shape and color of the flame are different from usual? Problem solving guideGas flame goes out after being lit? Electric spark ignition for the gas burner no longer works?After Sales Service ÖElectrical connection Technical data CDN / USA@äElectrical connection Technical data AUS NZElectrical connection AUS Electrical connection NZÖGas connection Pressure regulator For CDN only Nominal rating for all types of gas USA/CDNFor USA only @äGas connection Nominal rating for all types of gas at the high settingAppliance dimensions Gas connection CDN/USA Gas connection AUS/NZ ÖInstructions for building-in Zone Combiset Place the seal provided f under the edge of the cooktop @äClearance above and around the appliance @äClearance above and around the appliance @äInstallation Installation Data plate details @äInstallation @äInstructions for building-in Reference table jet sizes ÖConversion to alternative types of gasNatural gas Liquid gas ÖConversion to alternative types of gas After conversion @äConversion to alternative types of gas RemarksConversion Natural gas Liquid gas @äConversion to alternative types of gas After conversion Page Page Page Alteration rights reserved / 22