@äConversion to alternative types of gas
Changing the main jet, (does not apply to conversion to Natural Gas).
Using a 10 mm socket spanner, loosen the main jet from their holders, using a 13 mm spanner to counterhold.
Screw in the new main jet, once again using the spanner to counterhold.
Changing the small jets
Natural gas
Liquid gas
The jets must be changed:
bSmall jet with smaller orifice (e. g. for liquid gas: 0.23)
cSmall jet with larger orifice (e. g. for liquid gas: 0.52)
Using a small screwdriver, unscrew both small jets in the gas fitting.
Pull the jets out with a pair of pliers. Select the jets as shown in the table and fit, reversing the procedure, and secure.
38