Miele KM 81-2 Pressure regulator For CDN only, Nominal rating for all types of gas USA/CDN

Page 21

Gas connection

Pressure regulator

For CDN only

A pressure regulator convertible to Natural and LP Gas (Liquefied Petroleum) is included with the appliance.

Conversion is carried out by inverting the regulator cap marked "NAT"/"LP". If "NAT" is visible then the regulator is set for Natural gas and if "LP" is visible then it is set for Liquefied Petroleum Gas.

Nominal rating for all types of gas (USA/CDN)

Maximum output . 4.25 kW 14500 Btu/h

Minimum output . . . . . 0.2 kW 680 Btu/h

For USA only

The gas connection must be made in accordance with local codes, or in absence of local codes, with the National Fuel Gas Code,

ANSI Z 223.1.

Gas Pressures for USA:

Max. Supply Pressure: 1/2 PSI

Manifold pressure:

Natural gas 4" water column

Propane gas 10" water column Min. Supply Pressure:

Natural gas 5" water column

Propane gas 11" water column

The gas connection must be made in accordance with local codes, or in absence of local codes, with the current CAN/CGA B 149.1 and .2 Inst.

Gas Pressures for CDN

Manifold pressure:

Natural gas 4" water column

Propane gas 10" water column Min. Supply Pressure:

Natural gas 5" water column

Propane gas 11" water column

21

Image 21
Contents @äö Description of the appliance Stainless steel cover-EA Data plateContents For Canada only For your safetyHelp protect our environment Disposal of packagingDisposal of your old machine Important notes for the installer Important safety instructionsPage Page Save the Instructions Burner control BurnerPower cut Shape of woks, pots and pans MaterialWok / Pan base LidsCleaning and care Burner capsElectronic ignition Wok/pan support, trivet Cooktop surfaceControl panel / Control knob Shape and color of the flame are different from usual? Problem solving guideGas flame goes out after being lit? Electric spark ignition for the gas burner no longer works?After Sales Service ÖElectrical connection Technical data CDN / USA@äElectrical connection Technical data AUS NZElectrical connection AUS Electrical connection NZÖGas connection Pressure regulator For CDN only Nominal rating for all types of gas USA/CDNFor USA only @äGas connection Nominal rating for all types of gas at the high settingAppliance dimensions Gas connection CDN/USA Gas connection AUS/NZ ÖInstructions for building-in Zone Combiset Place the seal provided f under the edge of the cooktop @äClearance above and around the appliance @äClearance above and around the appliance @äInstallation InstallationData plate details @äInstallation @äInstructions for building-in Reference table jet sizes ÖConversion to alternative types of gasNatural gas Liquid gas ÖConversion to alternative types of gas After conversion @äConversion to alternative types of gas RemarksConversion Natural gas Liquid gas @äConversion to alternative types of gas After conversion Page Page Page Alteration rights reserved / 22