Fisher & Paykel DD607, DD247 service manual Component Specifications, Types - Single / Double

Page 10
Component Specifications

10

Component Specifications

Component

 

Specification

Controller

NZ, AU, GB, EU, DK

230V

 

US, CA, TW

120V

Water Inlet Valve

all markets

24V DC

 

 

65+/- 10 Ohms per coil

 

 

2.5litres/min (0.65 US gal/min)

Dispenser Coils

all markets

24V DC per coil

 

 

65+/- 10 Ohms per coil

Rinse Aid Tank

all markets

50mls (approx. 25 washes)

 

 

3.05 cubic inches

PCB Mains Filter

NZ, AU, GB, EU, DK

230V AC

(2 Types - Single / Double)

US, CA, TW

110V AC

Motor

 

80V DC 3 Phase Brushless

Drain Speed

Pump out rate 5 litres / min.

5000 RPM

Wash Speed

 

2200 - 2800 RPM

Stator

 

8.0 Ohms (per winding), 16 ohms phase to

 

 

phase from the controller connector

Heater plate 230V

NZ, AU, GB, EU, DK

230V AC

Wattage

 

1045W

Water Heater Track

 

50 Ohms +/- 4 Ohms

Power Supply Resistor

 

98 Ohms +/- 7 Ohms

Temperature Sensor

Located on the heater plate

12000 Ohms @ 20 oC

 

 

8300 Ohms @ 30 oC

 

 

3000 Ohms @ 60 oC

Heater Plate 110V

US, CA, TW

120V AC

Wattage

 

650W

Water Heater Track

 

24 Ohms +/- 3 Ohms

Power Supply Resistor

 

24 Ohms +/- 3 Ohms

Temperature Sensor

Located on the heater plate

12000 Ohms @ 68 oF

 

 

8300 Ohms @ 86 oF

 

 

3000 Ohms @ 140 oF

Fusible link

Located on the heater plate

268 – 302 oC (514 – 576 oF)

Water Inlet hose

Pressure Rating

1MPa (145psi)

 

Length from chassis edge

1650mm (64 ¾” ) left hand side

 

(viewed from the front)

1250mm (49”) Right hand side

Water Pressure

Non water softener models

1MPa (145 psi) max,

 

 

0.03 MPa (4.3psi) min

 

Water softener models

1MPa (145psi) max,

 

 

0.1MPa (14.5psi) min

Drain Hose

 

2000 mm (78 ½” )from left hand side

 

 

1800mm (70 ½”) from right hand side.

Power Cord

NZ, AU, GB, EU, DK

1650mm

 

length from chassis exit when

 

 

product viewed from the front

 

 

US, CA, TW

29 ½” LH side, 27 ½” RH side

Image 10
Contents NZ AU GB IE US CA Service ManualDishDrawer DD607 & DD247Standard Double Models FEATURED PRODUCT & CONTACT ADDRESSESBrand DescriptionSingle, Designer, Brushed Stainless Standard Single ModelsDD24SCW7 Tall Tub Double ModelsSingle, Tall Tub, Classic White Tall Tub Single ModelsDD24SDFTX7 Single, Tall Tub, Classic, Stainless SteelCONTENTS SERVICE PROCEDURES WIRING DIAGRAMS10 NOTES 1.1.9 Diagnostics 1 SERVICE REQUIREMENTS1.1.1 Electrical Safety 1.1.2 Electrostatic Discharge1.2 Specialised Tools 1.2.1 Static Strap22 15/16 ” 2 DIMENSIONS & SPECIFICATIONS22 15/16” 8.0 Ohms per winding, 16 ohms phase to Component SpecificationsSpecification ComponentHall sensor Post Wash CycleWash TimeWash Cycle DD60 Australia/New Zealand Wash ProfilesDD60 United States/Canada Wash Profiles Wash3 TECHNICAL OVERVIEW 3.3.1 Tub Home Sensor3.3.3 Wireless Remote some integrated models only 3.3.2 Touch Switches3.3.4 Operation some integrated models only Sluicing Jets 3.3.5 Wireless ReceiverAir Valve 3.4.1 Rotor3.4.3 Filter Plate 3.4.4 Drain Filter3.5.2 During a Power Failure 3.5.1 When Activated3.7.1 Water Inlet Flood Sensor 3.7.2 Dispensing Detergent and Rinse Aid3.7.3 Amount of Water 3.7.4 Flood Protection3.8.3 Maintaining the Temperature 3.8.1 The Heating Element3.8.2 Heating the Water 3.8.4 Over Heat ProtectionNon Return Valve 3.11.2 Removing and Cleaning the Drain Filter and Filter Plate 3.11.1 The Filter System3.12.1 Integrated Single Drawer Venting some models only Strainer Spigot Strainer 4.1.2 Rinse Aid Setup rA 4 OPTION ADJUSTMENT MODENot Wireless Model SetupGrains per Gallon DishDrawer Setting4.1.3 Water Supply Hardness Setup hd Parts per Million4.2.1 Classic Models 4.2.2 Designer Models4.2.3 Integrated Models 4.2.4 Integrated with Wireless Remote Controlbutton, which will increase or decrease the amount of LED’s on the Rinse aid Closed Drawer autolock using the remote controlOption Water softener5.1.1 Display Mode 5 DIAGNOSTICS5.1.2 Hardware Output Mode HO Rinse Aid Pump operates as a valve for diagnostic purposes only 5.1.3 Fast Cycle FC 5.1.4 Continuous Cycle Mode CC5.1.6 Show Off/ Showroom Wash Mode 5.1.5 Temperature and Voltage DisplayPlaying Tunes Program Button 5.2.1 Diagnostic ModeProgram Indicators 5.2.2 Display Mode5.2.4 Fast Cycle Mode FC 5.2.5 Continous Cycle Mode CC6 FAULT CODES AND POOR PERFORMANCE LED Display Fault CodeFault Possible Causes6.1.1 Sub Code Faults Fast, Delicate Fast & Eco LED’sIs the customer complaining of Poor Dry Performance Non VentedQUESTION plastic items not drying?Customers Complaint - food particles left on dishes How to resolve theproblem Customers Complaint - coffee/tea stains left in cupswhite chalky film on them More on next pageHow to resolve the problem 7 FAULT FINDING PROCEDURE 7.1 Fault Code Problem SolvingWet E1- Water in the Chassis Base DO NOT REPLACE COMPONENTS ON A TUB WITH THIS WARNINGDry E1 - No Water in the Chassis Base Prefinished models Fault code E2 - Sub Code 03 - Motor Not Drawing Enough Current Controller Harness P201 Corrosion Damage ExampleNOTE For more detailed component testing, refer to page Fault Code E5 - Sub Code 02 - No Current Fault Code E5 - Lid FaultFault Code E5 - Sub Code 01 - Not Starting Fault Code E5 - Sub Code 04 - Not StallingFan Housing Locking Tabs FlapFault Code E7 - Sub Code 03 - Over Current Fault Code E7 - Detergent Diverter ValveFault Code E7 - Sub Code 02 - Under Current Detergent Diverter Coil Harness Pin PinWater softener brine pump There are 4 sub codes which relate to this fault code If the problem persists replace the bottom controller 8.2 Power Distribution Concept 8 WIRING DIAGRAMS  8.3 Wiring DiagramLower Tub Shown Only  P203 9 SERVICE PROCEDURESP204 P2021. Open the drawer Clip Cowling Retaining ScrewRail Clip 1. Open the drawer and remove the drawer front refer section 1. Remove the drawer front refert section 1. Remove the cutlery basket and rack from the tub 1. Remove the drawer front refer Section Clips Clips Earth Wire Element CoverDrain Hose Fill Hose 1. Remove the wiring cover refer section 1. Remove the tub as per section Trim Trim ChannelWater Valve Hex Drive Screws Rail Rear Locating TabsClips Inlet Hose Flood Sensor MFB Wiring Harness Link Clip 15mm 3/4” Fill Hoses Water Inlet Hose Chassis ClipT10 Torx Screw 9.28 Single Integrated Vent Duct Removal Some models onlyTrim Clips Slide Off Tub1. Remove the tub to gain access to the duct, refer section 1. Remove the door panel, refer section Receiver Replacement Procedure Pairing ProcedureTo Pair Remote to Receiver Transmit LED indicator Top Tub start button on doubles 10 NOTES NZ AU GB IE US CA F&P PN 590409 A 11.2011