69
9.24Water Inlet Valve
1.Remove the lower tub, refer section 9.6.
2.Remove the mains filter cover, refer section 9.23.
3.Partially lift the inlet valve up out of the housing.
4.Disconnect the water inlet hose connection, CAUTION - water will drip.
5.The water valve can now be removed up and out of the housing.
6.Remove the wire harnesses, and mark which fill hose goes to the top on a double product. Unclip the hose
clips by pushing the ends apart sideways, then remove the hoses from the valve.
7.Refit in reverse manner.
9.25Fill Hose, Drain Hose, Wiring Harness Replacement
1.Remove the tub and turn it over by rotating it anticlockwise (refer section 9.6).
2.Remove the wiring cover, refer section 9.15.
3.Disconnect the component you need to replace (e.g. fill hose, drain hose, wiring harness) from the tub.
4.Undo the link clips and chassis clips, do this one clip at a time, marking the position of the hoses and harnesses at each clip and
5.Refit in reverse manner, ensuring the link and chassis clips are clamping the components in their correct location.
9.26 Link Support Wire Position
1.If the latches are resetting, this can be caused by the link support wire being positioned too low and allowing the hoses and harnesses to get between the tub and the latch.
2.To check the position of the wire, remove the tub, and remove the centre link clip from the wire. Swing the wire to the left hand side of the chassis.
3.It should rest approx 15mm (3/4”) above the slide mounting bracket. If not, then carefully bend the wire while supporting it at the rear so as not to stress the mounting bracket.
Wiring Harness
Link Clip
15mm (3/4”)
Fill Hoses
Water Inlet Hose
Chassis Clip