Fisher & Paykel DD247, DD607 service manual Wiring Harness Link Clip 15mm 3/4”

Page 69
Wiring Harness

69

9.24Water Inlet Valve

1.Remove the lower tub, refer section 9.6.

2.Remove the mains filter cover, refer section 9.23.

3.Partially lift the inlet valve up out of the housing.

4.Disconnect the water inlet hose connection, CAUTION - water will drip.

5.The water valve can now be removed up and out of the housing.

6.Remove the wire harnesses, and mark which fill hose goes to the top on a double product. Unclip the hose

clips by pushing the ends apart sideways, then remove the hoses from the valve.

7.Refit in reverse manner.

9.25Fill Hose, Drain Hose, Wiring Harness Replacement

1.Remove the tub and turn it over by rotating it anticlockwise (refer section 9.6).

2.Remove the wiring cover, refer section 9.15.

3.Disconnect the component you need to replace (e.g. fill hose, drain hose, wiring harness) from the tub.

4.Undo the link clips and chassis clips, do this one clip at a time, marking the position of the hoses and harnesses at each clip and re-closing it after the component is removed to keep the other two components in their correct positions. The faulty component can now be disconnected from the chassis end and removed.

5.Refit in reverse manner, ensuring the link and chassis clips are clamping the components in their correct location.

9.26 Link Support Wire Position

1.If the latches are resetting, this can be caused by the link support wire being positioned too low and allowing the hoses and harnesses to get between the tub and the latch.

2.To check the position of the wire, remove the tub, and remove the centre link clip from the wire. Swing the wire to the left hand side of the chassis.

3.It should rest approx 15mm (3/4”) above the slide mounting bracket. If not, then carefully bend the wire while supporting it at the rear so as not to stress the mounting bracket.

Wiring Harness

Link Clip

15mm (3/4”)

Fill Hoses

Water Inlet Hose

Chassis Clip

Image 69
Contents DishDrawer Service ManualNZ AU GB IE US CA DD607 & DD247Brand FEATURED PRODUCT & CONTACT ADDRESSESStandard Double Models DescriptionDD24SCW7 Standard Single ModelsSingle, Designer, Brushed Stainless Tall Tub Double ModelsDD24SDFTX7 Tall Tub Single ModelsSingle, Tall Tub, Classic White Single, Tall Tub, Classic, Stainless SteelCONTENTS WIRING DIAGRAMS SERVICE PROCEDURES10 NOTES 1.1.1 Electrical Safety 1 SERVICE REQUIREMENTS1.1.9 Diagnostics 1.1.2 Electrostatic Discharge1.2.1 Static Strap 1.2 Specialised Tools2 DIMENSIONS & SPECIFICATIONS 22 15/16 ”22 15/16” Specification Component Specifications8.0 Ohms per winding, 16 ohms phase to ComponentHall sensor Wash Wash CyclePost TimeDD60 United States/Canada Wash Profiles DD60 Australia/New Zealand Wash ProfilesWash Cycle Wash3.3.1 Tub Home Sensor 3 TECHNICAL OVERVIEW3.3.2 Touch Switches 3.3.3 Wireless Remote some integrated models only3.3.4 Operation some integrated models only Air Valve 3.3.5 Wireless ReceiverSluicing Jets 3.4.1 Rotor3.4.4 Drain Filter 3.4.3 Filter Plate3.5.1 When Activated 3.5.2 During a Power Failure3.7.1 Water Inlet 3.7.3 Amount of Water 3.7.2 Dispensing Detergent and Rinse AidFlood Sensor 3.7.4 Flood Protection3.8.2 Heating the Water 3.8.1 The Heating Element3.8.3 Maintaining the Temperature 3.8.4 Over Heat ProtectionNon Return Valve 3.11.1 The Filter System 3.11.2 Removing and Cleaning the Drain Filter and Filter Plate3.12.1 Integrated Single Drawer Venting some models only Strainer Spigot Strainer Not Wireless Model 4 OPTION ADJUSTMENT MODE4.1.2 Rinse Aid Setup rA Setup4.1.3 Water Supply Hardness Setup hd DishDrawer SettingGrains per Gallon Parts per Million4.2.2 Designer Models 4.2.1 Classic Models4.2.4 Integrated with Wireless Remote Control 4.2.3 Integrated Modelsbutton, which will increase or decrease the amount of LED’s on the Option Closed Drawer autolock using the remote controlRinse aid Water softener5 DIAGNOSTICS 5.1.1 Display Mode5.1.2 Hardware Output Mode HO Rinse Aid Pump operates as a valve for diagnostic purposes only 5.1.4 Continuous Cycle Mode CC 5.1.3 Fast Cycle FC5.1.5 Temperature and Voltage Display 5.1.6 Show Off/ Showroom Wash ModePlaying Tunes Program Indicators 5.2.1 Diagnostic ModeProgram Button 5.2.2 Display Mode5.2.5 Continous Cycle Mode CC 5.2.4 Fast Cycle Mode FC6 FAULT CODES AND POOR PERFORMANCE Fault Fault CodeLED Display Possible Causes6.1.1 Sub Code Faults Fast & Eco LED’s Fast, DelicateQUESTION Poor Dry Performance Non VentedIs the customer complaining of plastic items not drying?problem How to resolve theCustomers Complaint - food particles left on dishes Customers Complaint - coffee/tea stains left in cupsMore on next page white chalky film on themHow to resolve the problem 7.1 Fault Code Problem Solving 7 FAULT FINDING PROCEDUREDO NOT REPLACE COMPONENTS ON A TUB WITH THIS WARNING Wet E1- Water in the Chassis BaseDry E1 - No Water in the Chassis Base Prefinished models Controller Harness P201 Corrosion Damage Example Fault code E2 - Sub Code 03 - Motor Not Drawing Enough CurrentNOTE For more detailed component testing, refer to page Fault Code E5 - Sub Code 01 - Not Starting Fault Code E5 - Lid FaultFault Code E5 - Sub Code 02 - No Current Fault Code E5 - Sub Code 04 - Not StallingFlap Fan Housing Locking TabsFault Code E7 - Sub Code 02 - Under Current Fault Code E7 - Detergent Diverter ValveFault Code E7 - Sub Code 03 - Over Current Detergent Diverter Coil Harness Pin PinWater softener brine pump There are 4 sub codes which relate to this fault code If the problem persists replace the bottom controller 8 WIRING DIAGRAMS 8.2 Power Distribution Concept Lower Tub Shown Only 8.3 Wiring Diagram  P204 9 SERVICE PROCEDURESP203 P2021. Open the drawer Retaining Screw Clip CowlingRail Clip 1. Open the drawer and remove the drawer front refer section 1. Remove the drawer front refert section 1. Remove the cutlery basket and rack from the tub 1. Remove the drawer front refer Section Earth Wire Element Cover Clips ClipsDrain Hose Fill Hose 1. Remove the wiring cover refer section 1. Remove the tub as per section Trim Channel TrimHex Drive Screws Rail Rear Locating Tabs Water ValveClips Inlet Hose Flood Sensor MFB Fill Hoses Water Inlet Hose Chassis Clip Wiring Harness Link Clip 15mm 3/4”Trim Clips 9.28 Single Integrated Vent Duct Removal Some models onlyT10 Torx Screw Slide Off Tub1. Remove the tub to gain access to the duct, refer section 1. Remove the door panel, refer section Pairing Procedure Receiver Replacement ProcedureTo Pair Remote to Receiver Transmit LED indicator Top Tub start button on doubles 10 NOTES 11.2011 NZ AU GB IE US CA F&P PN 590409 A