65
9.17Hall Sensor
1.Remove the wiring cover (refer section 9.15)
2.Unplug the wiring connection from the hall sensor
3.Gently press the hall sensor locking tab in the direction shown and lift the hall sensor out.
4. Refit in reverse manner and ensure the hall sensor is properly clipped in.
Locating Pin
Locking Tab
9.18 Heater Plate and Motor Assembly
1.Remove the drawer front (refer section 9.2), baskets, filter plate (refer section 9.11) and rotor assembly (refer section 9.12).
2.Remove the tub and rotate
3.Remove the wiring cover (refer section 9.15)
4.Remove the element connector cover and element wiring connector.
5.Remove the drain hose and heater plate earth wire.
6.While lifting the locking tab on the outer locknut, rotate the outer locknut
7.Lift the rear of the heater plate and motor assembly clear of the tub and slide the drain spigot out of the tub drain area.
8.Remove the inner locknut and motor shim to release the motor assembly from the heater plate. Take care with the seals between the motor assembly and the heater plate, and the heater plate and tub. Their seals and their corresponding sealing surfaces must be clean and the seals correctly placed during reassembly.
9.Check both the drain hose
10.Reassemble in reverse manner, ensuring all the locking ring tabs are engaged.
Lock Tab