Fisher & Paykel DD247, DD607 service manual Filter Plate, Drain Filter

Page 17
3.4.3 Filter Plate

17

3.4.3 Filter Plate

The filter plate is a stainless steel disk positioned below the dish rack and spray arm and completely encompasses the base of the tub.

The drain filter has a rubber over mould around the edge to reduce soil re-depositing. Between the filter plate and rotor an o ring is also fitted to ensure a tight fit to reduce water leaks. These improvements will ensure a better wash performance.

The drain filter fits tightly into the filter plate, due to the rubber over mould around the edge.

3.4.4 Drain Filter

The tub has vanes that swirl the water around and over the filter plate. At the front of the tub, located as part of the filter plate, is the drain filter.

The drain filter is secured into the filter plate over mould which helps sealing.

Large soils collect in the drain filter and only smaller soil flows through its micro-mesh filter, eliminating re-depositing of soil during the wash.

The drain filter should be regularly checked and cleaned.

Image 17
Contents DishDrawer Service ManualNZ AU GB IE US CA DD607 & DD247Brand FEATURED PRODUCT & CONTACT ADDRESSESStandard Double Models DescriptionDD24SCW7 Standard Single ModelsSingle, Designer, Brushed Stainless Tall Tub Double ModelsDD24SDFTX7 Tall Tub Single ModelsSingle, Tall Tub, Classic White Single, Tall Tub, Classic, Stainless SteelCONTENTS 10 NOTES WIRING DIAGRAMSSERVICE PROCEDURES 1.1.1 Electrical Safety 1 SERVICE REQUIREMENTS1.1.9 Diagnostics 1.1.2 Electrostatic Discharge1.2.1 Static Strap 1.2 Specialised Tools22 15/16” 2 DIMENSIONS & SPECIFICATIONS22 15/16 ” Specification Component Specifications8.0 Ohms per winding, 16 ohms phase to ComponentHall sensor Wash Wash CyclePost TimeDD60 United States/Canada Wash Profiles DD60 Australia/New Zealand Wash ProfilesWash Cycle Wash3.3.1 Tub Home Sensor 3 TECHNICAL OVERVIEW3.3.4 Operation some integrated models only 3.3.2 Touch Switches3.3.3 Wireless Remote some integrated models only Air Valve 3.3.5 Wireless ReceiverSluicing Jets 3.4.1 Rotor3.4.4 Drain Filter 3.4.3 Filter Plate3.7.1 Water Inlet 3.5.1 When Activated3.5.2 During a Power Failure 3.7.3 Amount of Water 3.7.2 Dispensing Detergent and Rinse AidFlood Sensor 3.7.4 Flood Protection3.8.2 Heating the Water 3.8.1 The Heating Element3.8.3 Maintaining the Temperature 3.8.4 Over Heat ProtectionNon Return Valve 3.11.1 The Filter System 3.11.2 Removing and Cleaning the Drain Filter and Filter Plate3.12.1 Integrated Single Drawer Venting some models only Strainer Spigot Strainer Not Wireless Model 4 OPTION ADJUSTMENT MODE4.1.2 Rinse Aid Setup rA Setup4.1.3 Water Supply Hardness Setup hd DishDrawer SettingGrains per Gallon Parts per Million4.2.2 Designer Models 4.2.1 Classic Modelsbutton, which will increase or decrease the amount of LED’s on the 4.2.4 Integrated with Wireless Remote Control4.2.3 Integrated Models Option Closed Drawer autolock using the remote controlRinse aid Water softener5.1.2 Hardware Output Mode HO 5 DIAGNOSTICS5.1.1 Display Mode Rinse Aid Pump operates as a valve for diagnostic purposes only 5.1.4 Continuous Cycle Mode CC 5.1.3 Fast Cycle FCPlaying Tunes 5.1.5 Temperature and Voltage Display5.1.6 Show Off/ Showroom Wash Mode Program Indicators 5.2.1 Diagnostic ModeProgram Button 5.2.2 Display Mode5.2.5 Continous Cycle Mode CC 5.2.4 Fast Cycle Mode FC6 FAULT CODES AND POOR PERFORMANCE Fault Fault CodeLED Display Possible Causes6.1.1 Sub Code Faults Fast & Eco LED’s Fast, DelicateQUESTION Poor Dry Performance Non VentedIs the customer complaining of plastic items not drying?problem How to resolve theCustomers Complaint - food particles left on dishes Customers Complaint - coffee/tea stains left in cupsMore on next page white chalky film on themHow to resolve the problem 7.1 Fault Code Problem Solving 7 FAULT FINDING PROCEDUREDry E1 - No Water in the Chassis Base DO NOT REPLACE COMPONENTS ON A TUB WITH THIS WARNINGWet E1- Water in the Chassis Base Prefinished models Controller Harness P201 Corrosion Damage Example Fault code E2 - Sub Code 03 - Motor Not Drawing Enough CurrentNOTE For more detailed component testing, refer to page Fault Code E5 - Sub Code 01 - Not Starting Fault Code E5 - Lid FaultFault Code E5 - Sub Code 02 - No Current Fault Code E5 - Sub Code 04 - Not StallingFlap Fan Housing Locking TabsFault Code E7 - Sub Code 02 - Under Current Fault Code E7 - Detergent Diverter ValveFault Code E7 - Sub Code 03 - Over Current Detergent Diverter Coil Harness Pin PinWater softener brine pump There are 4 sub codes which relate to this fault code If the problem persists replace the bottom controller  8 WIRING DIAGRAMS8.2 Power Distribution Concept Lower Tub Shown Only 8.3 Wiring Diagram  P204 9 SERVICE PROCEDURESP203 P2021. Open the drawer Rail Clip Retaining ScrewClip Cowling 1. Open the drawer and remove the drawer front refer section 1. Remove the drawer front refert section 1. Remove the cutlery basket and rack from the tub 1. Remove the drawer front refer Section Drain Hose Fill Hose Earth Wire Element CoverClips Clips 1. Remove the wiring cover refer section 1. Remove the tub as per section Trim Channel TrimClips Inlet Hose Flood Sensor MFB Hex Drive Screws Rail Rear Locating TabsWater Valve Fill Hoses Water Inlet Hose Chassis Clip Wiring Harness Link Clip 15mm 3/4”Trim Clips 9.28 Single Integrated Vent Duct Removal Some models onlyT10 Torx Screw Slide Off Tub1. Remove the tub to gain access to the duct, refer section 1. Remove the door panel, refer section To Pair Remote to Receiver Pairing ProcedureReceiver Replacement Procedure Transmit LED indicator Top Tub start button on doubles 10 NOTES 11.2011 NZ AU GB IE US CA F&P PN 590409 A