Cleveland Range KGL-80-T, KGL-40-SH, KGL-100, KGL-40-T manual KE53441 BLOWER, 115V, 60 HZ

Page 19

GAS CONTROL ASSEMBLY

 

ITEM ON.

PART NO.

DESCRIPTION

QTY.

1.

KE53441

BLOWER, 115V, 60 HZ

. . .1

 

KE53441-1

BLOWER, 220V, 50 HZ

. . .1

2.

KE54420

AIR INTAKE WASHER (NATURAL GAS)

. . .1

 

KE54420-1

AIR INTAKE WASHER (PROPANE)

. . .1

3.

KE54239

CAPACITOR

. . .1

4.

KE01426-4

MIXING CHAMBER, 40 GALLON KETTLES

. . .1

 

KE01426-1

MIXING CHAMBER, 60 GALLON KETTLES

. . .1

 

KE01426-2

MIXING CHAMBER, 80 GALLON KETTLES

. . .1

 

KE01426-3

MIXING CHAMBER, 100 GALLON KETTLES

. . .1

5.

KE53523

1/4” TUBING

. . .1

6.

KE53402

AIR ORIFICE, 40 GALLON KETTLES

. . .1

 

KE53402-1

AIR ORIFICE, 60 - 100 GALLON KETTLES

. . .1

 

KE53402-2

AIR ORIFICE, 40 GALLON KETTLES (FOR FRANCE ONLY)

. . .1

 

KE53402-3

AIR ORIFICE, 60 - 100 GALLON KETTLES (FOR FRANCE ONLY)

. . .1

7.

KE01449

BLOWER MOUNTING PIPE ASSEMBLY

. . .1

8.

KE53618

SIGHT GLASS GASKET

. . .1

9.

KE53617

SIGHT GLASS

. . .1

10.

KE53619

SIGHT GLASS RETAINER

. . .1

11.

KE00515

THERMISTOR

. . .1

12.

KE50556-2

WATER LEVEL PROBE

. . .1

13.

KE53437

IGNITOR

. . .1

14.

KE53570

GASKET FOR IGNITOR

. . .1

15.

FI05257

SHUT-OFF COCK

. . .1

16.

FI05213

PLUG

. . .1

17.

KE53422

SPRING

. . .1

18.

FA05002-4

“O” RING

. . .1

19.GAS ORIFICES:

 

KE53403-4

NATURAL GAS - SEA LEVEL UP TO 2000', 40 GALLON KETTLES

.1

 

KE53403-5

PROPANE GAS - SEA LEVEL UP TO 2000', 40 GALLON KETTLES

.1

 

KE53403-6

NATURAL GAS - SEA LEVEL UP TO 2000', 60 - 100 GALLON KETTLES

.1

 

KE53403-7

PROPANE GAS - SEA LEVEL UP TO 2000', 60 - 100 GALLON KETTLES

.1

 

KE53403-8

NATURAL GAS - 2000' UP TO 4000', 40 GALLON KETTLES

.1

 

KE53403-9

PROPANE GAS - 2000' UP TO 4000', 40 GALLON KETTLES

.1

 

KE53403-10

NATURAL GAS - 2000' UP TO 4000', 60 - 100 GALLON KETTLES

.1

 

KE53403-11

PROPANE GAS - 2000' TO 4000', 60 - 100 GALLON KETTLES

.1

 

KE53403-12

NATURAL GAS - 4000' UP TO 6000', 40 GALLON KETTLES

.1

 

KE53403-13

PROPANE GAS - 4000' UP TO 6000', 40 GALLON KETTLES

.1

 

KE53403-10

NATURAL GAS - 4000' UP TO 6000', 60 - 100 GALLON KETTLES

.1

 

KE53403-14

PROPANE GAS - 4000' UP TO 6000', 60 - 100 GALLON KETTLES

.1

20.

FA05002-29

“O” RING

.1

21.

FI05226-4

NIPPLE, 1/2" NPT, 5 5/16" LONG

.1

22.

FI00073

UNION, 1/2"

.1

23.

FI00133

ELBOW, 1/2", STREET

.1

24.

KE93909

STRIP, TO HOLD BLOWER DOWN

.1

25.

FI00040-1

ELBOW, 1/2"

.1

26.

FI00579

NIPPLE, 1/2" NPT, 4" LONG, KGL-60-T

.1

 

FI05226-2

NIPPLE, 1/2" NPT, 4" LONG, KGL-80-T

.1

27.

KE55004-3

RETAINING PLATE

.1

28.

FI00573

NIPPLE, 1/2" NPT, 1 1/8" LONG

.1

29.

FI05231

BUSHING, 3/4 - 1/2" NPT FLUSH, BLACK IRON

.1

30.

F01518-1

GAS SHUT-OFF VALVE, 3/4"

.1

31.

FI05226

NIPPLE, 1/2" NPT, 8" LONG

.1

32.

FI05222

SWIVEL ELBOW

.1

33.

FI05223

SPECIAL NIPPLE

.1

34.

KE02053

GAS VALVE ASSEMBLY

.1

35.

KE53515

GAS VALVE

.1

36.

FI00607

NIPPLE, 3/4" NPT, 1 1/2" LONG

.1

16

Image 19
Contents Operators Manual Retain this Manual for Your Reference For the UserTable of Contents Ventilation InstallationInspection GeneralWater CleaningInstallation Checks ElectricalSpecification Drawing Tilting, KGL-40-T, KGL-60-T, KGL-80-T Short Series, KGL-40-SH, KGL-60-SH Short Series, KGL-40-TSH Operating Instructions Approximate Boiling Times Operating the KettleCare and Cleaning Cleaning InstructionsWrap Covers Service PartsItem no Description QTY Pressure Relief AssemblyHinge Assembly KGL-40/T Hinge AssemblySight Glass Electrical Component BOXTangent DRAW-OFF Valve Trunnion AssemblyStationary Models GAS Control AssemblyKE53441 BLOWER, 115V, 60 HZ Gearbox Assembly KE52836-2 Potentiometer Used Prior to January Console ControlsInspection and Maintenance Checklist MaintenanceKettle Safety Inspection Checklist Safety Thermostat Hinge Adjustment Instructions Lubrication ProcedureTroubleshooting Guides Problem KGL Problem Repairing Leaks in Steam Jacketed Kettle Fittings Vacuum Leak Test ProcedureKettle Venting Kettle Jacket will Result in Irreversible Damage to Unit Reservoir Fill ProceduresCalibrating Procedure Pressure Relief Valve Periodic TestingRecommended Corrosion Inhibitors for Closed Systems Kettle Jacket Filling & Draining ProceduresReplace Spring and Plug Replace Console Cover GAS Kettle Orifice ReplacementConversion Parts Required Wiring Diagrams Ignitor KE53838-2 KE53441-1 BLOWER, 220V, 50 HZ KE53838-2 Symbol Legend page 1 Symbol Legend page 2 Part Number Description Quantity Spare Parts List

KGL-40, KGL-60, KGL-80, KGL-100, KGL-40-T, KGL-60-T, KGL-80-T, KGL-40-SH, KGL-60-SH, KGL-40-TSH, KGL-100, KGL-40-T, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-80-T, KGL-40-SH specifications

Cleveland Range has established itself as a leading manufacturer of high-quality commercial kitchen equipment, particularly known for its diverse range of steamers. Among their notable offerings are the Cleveland Range KGL series models including KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, and KGL-60-T. These models are specifically designed to meet the needs of busy commercial kitchens, providing efficiency, durability, and precision in cooking.

The KGL-80-T model stands out with its generous cooking capacity, making it ideal for large-scale food preparation. It is equipped with advanced controls that allow for easy monitoring of cooking times and temperatures, ensuring that food is cooked evenly and to perfection. The integrated steaming technology maintains high levels of moisture, preserving the flavor and nutritional value of the food.

The KGL-40-SH and KGL-40-TSH models are tailored for mid-sized operations but still offer robust performance. These steamers incorporate user-friendly digital controls that facilitate hassle-free operation. The stainless-steel construction ensures durability and ease of cleaning, essential for maintaining hygiene in a busy kitchen environment.

Cleveland's KGL-40-T and KGL-40SH versions feature energy-efficient options, significantly reducing water and energy consumption without compromising on cooking quality. These models utilize a sophisticated water level management system that minimizes operational costs while maximizing cooking efficiency.

For establishments requiring even larger capacities, the KGL-100 model is an ideal solution, designed to cater to extensive foodservice operations. It boasts advanced steam generation technology, allowing for rapid heating and cooking. The ability to stack multiple trays enhances its functionality, making it a powerful tool for large events or high-demand services.

The KGL-60 and KGL-60-T models blend functionality with advanced features. The digital control panel provides precise steam control, time management, and temperature settings. Users can easily program multiple recipes, making it convenient to switch between different dishes quickly.

In summary, Cleveland Range's KGL series, including the KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, KGL-60-T, and others, epitomize excellence in commercial kitchen technology. With their commitment to quality, durability, and energy efficiency, these steamers are designed to enhance the culinary capabilities of any kitchen, ensuring that chefs can deliver exceptional meals consistently. Each model in the KGL series is tailored to meet the diverse needs of foodservice operations, from small restaurants to large catering businesses, ensuring optimal performance and reliability.