Cleveland Range KGL-80-T, KGL-40-SH, KGL-100, KGL-40-T manual Tilting, KGL-40-T, KGL-60-T, KGL-80-T

Page 7

Specification Drawing -

Tilting, KGL-40-T, KGL-60-T, KGL-80-T

 

A

2 1/4"

2 1/2"

 

 

(57 mm)

 

 

 

 

 

 

(64 mm)

M

 

 

REF

 

 

 

 

 

 

 

2 1/2"

 

 

 

E

(64 mm)

 

 

 

 

 

 

 

 

L

 

B

C

F

 

 

 

 

 

3"

(77 mm)

REF

P

Q

7/16" (11 mm) Ø

4

7/8"

3 HOLES ON

124

Ø mm

3 1/8" (80 mm) Ø

 

 

B.C.D.

 

 

 

120º

 

 

TYP

 

VALVE OPENING

D

HANDWHEEL REPLACED BY SWITCH FOR POWER TILT OPTION

4 1/8"

 

(105 mm)

 

N

O

1 5/8" (42 mm) Ø

 

1" (25 mm)

9/16"

MAX. ADJUSTMENT 14 mm

FLANGED FOOT DETAIL

S I.D.

G

H

J

UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE, SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.

DIMENSIONS

H C

 

 

 

 

4" (102 mm)

RECOMMENDED

 

 

 

RECOMMENDED

FLOOR SLOPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" (26 mm) per 4' (1220 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIPE DRAIN RECOMMENDED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

min. valve size plus 1" (26 mm)

 

 

 

 

 

 

 

 

 

3" (77 mm) MIN.

CLEARANCE

GALS./

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LITERS

A

B

C

D

E

F

G

H

J

K

L

M

N

O

P

Q

S I.D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

IN

45 3/4

42 1/2

38

35

9

42 1/4

71

40 1/2

15 1/2

23 1/4

19

35 3/4

4 3/8

24

33

63

26

150

mm

1163

108

966

889

229

1074

1804

1029

394

591

483

909

112

610

839

1601

661

60

IN

49 3/8

46

41 1/2

37

11 3/4 47 1/4

75

43 3/4

15 1/4

24 1/2

22

39 3/8

6

28

37

68

29 1/2

225

mm

1255

1169

1055

940

299

1201

1905

1112

388

623

559

1001

153

712

940

1728

750

80

IN

53

49

44 1/2

39

14 3/4

51

78

44 3/4

14

25

25

43

7

30

40

72

33

300

mm

1347

1245

1131

991

375

1296

1982

1137

356

635

635

1093

178

762

1016

1829

839

 

 

GAS

 

 

 

 

ELECTRIC

WATER H C

CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V-1 Phase, 60 Hz, 10

1/2" dia. Soft

RIGHT =

0"

 

NATURAL

PROPANE

 

B.T.U. RATING

 

 

 

 

 

 

 

 

amps

H C Copper

LEFT

=

0"

 

Piping: 3/4" N.P.T.

Piping: 3/4" N.P.T.

 

40 gal.

140,000

 

 

 

 

 

Tubing (each)

REAR

=

3"

 

Supply pressure:

Supply pressure:

 

60 gal.

 

 

 

 

 

 

 

 

When ordered

Allow 6" space minimum

 

4.00" W.C. minimum

4.00" W.C. minimum

 

80 gal.

190,000

 

 

 

 

 

 

from rear and sides when

 

 

 

 

with optional

 

14.00" W.C. maximum

14.00" W.C. maximum

 

100 gal.

 

 

 

located near combustible

 

 

 

 

 

faucet.

 

 

 

 

 

 

 

 

walls. 12" recommended on

 

Manufacturer must be notified if unit will be operated above 2,000 ft. altitude.

 

 

 

 

 

right side for service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Installation of backflow preventers, vacuum breakers and other specific codr requirements is the responsibility of the owner and installer.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

4

Image 7
Contents Operators Manual Retain this Manual for Your Reference For the UserTable of Contents Ventilation InstallationInspection GeneralWater CleaningInstallation Checks ElectricalSpecification Drawing Tilting, KGL-40-T, KGL-60-T, KGL-80-T Short Series, KGL-40-SH, KGL-60-SH Short Series, KGL-40-TSH Operating Instructions Approximate Boiling Times Operating the KettleCare and Cleaning Cleaning InstructionsWrap Covers Service PartsItem no Description QTY Pressure Relief AssemblyHinge Assembly KGL-40/T Hinge AssemblySight Glass Electrical Component BOXTangent DRAW-OFF Valve Trunnion AssemblyStationary Models GAS Control AssemblyKE53441 BLOWER, 115V, 60 HZ Gearbox Assembly KE52836-2 Potentiometer Used Prior to January Console ControlsInspection and Maintenance Checklist MaintenanceKettle Safety Inspection Checklist Safety Thermostat Hinge Adjustment Instructions Lubrication ProcedureTroubleshooting Guides Problem KGL Problem Repairing Leaks in Steam Jacketed Kettle Fittings Vacuum Leak Test ProcedureKettle Venting Kettle Jacket will Result in Irreversible Damage to Unit Reservoir Fill ProceduresCalibrating Procedure Pressure Relief Valve Periodic TestingRecommended Corrosion Inhibitors for Closed Systems Kettle Jacket Filling & Draining ProceduresReplace Spring and Plug Replace Console Cover GAS Kettle Orifice ReplacementConversion Parts Required Wiring Diagrams Ignitor KE53838-2 KE53441-1 BLOWER, 220V, 50 HZ KE53838-2 Symbol Legend page 1 Symbol Legend page 2 Part Number Description Quantity Spare Parts List

KGL-40, KGL-60, KGL-80, KGL-100, KGL-40-T, KGL-60-T, KGL-80-T, KGL-40-SH, KGL-60-SH, KGL-40-TSH, KGL-100, KGL-40-T, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-80-T, KGL-40-SH specifications

Cleveland Range has established itself as a leading manufacturer of high-quality commercial kitchen equipment, particularly known for its diverse range of steamers. Among their notable offerings are the Cleveland Range KGL series models including KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, and KGL-60-T. These models are specifically designed to meet the needs of busy commercial kitchens, providing efficiency, durability, and precision in cooking.

The KGL-80-T model stands out with its generous cooking capacity, making it ideal for large-scale food preparation. It is equipped with advanced controls that allow for easy monitoring of cooking times and temperatures, ensuring that food is cooked evenly and to perfection. The integrated steaming technology maintains high levels of moisture, preserving the flavor and nutritional value of the food.

The KGL-40-SH and KGL-40-TSH models are tailored for mid-sized operations but still offer robust performance. These steamers incorporate user-friendly digital controls that facilitate hassle-free operation. The stainless-steel construction ensures durability and ease of cleaning, essential for maintaining hygiene in a busy kitchen environment.

Cleveland's KGL-40-T and KGL-40SH versions feature energy-efficient options, significantly reducing water and energy consumption without compromising on cooking quality. These models utilize a sophisticated water level management system that minimizes operational costs while maximizing cooking efficiency.

For establishments requiring even larger capacities, the KGL-100 model is an ideal solution, designed to cater to extensive foodservice operations. It boasts advanced steam generation technology, allowing for rapid heating and cooking. The ability to stack multiple trays enhances its functionality, making it a powerful tool for large events or high-demand services.

The KGL-60 and KGL-60-T models blend functionality with advanced features. The digital control panel provides precise steam control, time management, and temperature settings. Users can easily program multiple recipes, making it convenient to switch between different dishes quickly.

In summary, Cleveland Range's KGL series, including the KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, KGL-60-T, and others, epitomize excellence in commercial kitchen technology. With their commitment to quality, durability, and energy efficiency, these steamers are designed to enhance the culinary capabilities of any kitchen, ensuring that chefs can deliver exceptional meals consistently. Each model in the KGL series is tailored to meet the diverse needs of foodservice operations, from small restaurants to large catering businesses, ensuring optimal performance and reliability.