Cleveland Range KGL-80-T, KGL-40-SH, KGL-100, KGL-40-T manual Short Series, KGL-40-SH, KGL-60-SH

Page 8

Specification Drawing -

Short Series, KGL-40-SH, KGL-60-SH,

DIMENSIONS

 

4" (102 mm)

 

RECOMMENDED

RECOMMENDED

FLOOR SLOPE

 

 

 

 

 

 

1" (26 mm) per 4' (1220 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIPE DRAIN RECOMMENDED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min. valve size plus 1" (26 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/16" (11 mm) Ø

4 7/8"

 

 

 

 

 

 

 

 

3 HOLES ON

 

 

124 Ø mm

 

 

 

 

3 1/8" (80 mm) Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B.C.D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120º

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYP

 

 

 

 

1 5/8" (42 mm) Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" (25 mm)

9/16"

 

 

 

 

 

MAX. ADJUSTMENT 14 mm

FLANGED FOOT DETAIL

MODEL NO

 

A

B

C

D

E

F

G

H

J

 

K

L

M

N

P

Q

 

 

S

T

KGL-40SH

IN

33

41.6

43.3

37.5

69

15.5

7.3

6.7

11

28

35.5

8.2

21.6

11.5

20.8

43.5

23

 

 

mm

838

1056

1099

953

1752

394

185

170

279

711

902

208

549

292

528

1105

584

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KGL-60SH

IN

33.5

44

43.5

37.5

71

12.1

7.3

5.5

12.6

30.5

35.5

8.2

22.2

13.7

22.1

44.5

24.5

 

 

mm

850

1117

1104

953

1803

307

185

140

320

775

902

208

564

348

561

1130

622

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

 

 

 

 

 

ELECTRIC

 

 

WATER

 

CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

PROPANE

BTU RATING

 

120V-1Phase, 60 Hz.

 

1/2" diameter

RIGHT = 0"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piping 3/4" N.P.T.

Piping 3/4" N.P.T.

190,000

 

 

10 amps

 

 

 

Soft Copper

LEFT

= 0"

 

 

 

 

 

 

Supply pressure

Supply pressure

 

 

 

 

 

 

 

 

Tubing each

REAR

= 0"

 

 

 

 

 

 

4.00" W.C. Min.

11.00" W.C. Min.

 

 

 

 

 

 

 

 

When ordered

Allow 6" space min.

 

 

 

 

 

14.00" W.C. Max.

14.00" W.C. Max.

 

 

 

 

 

 

 

 

with optional

from rear and sides

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

faucet

 

When located near

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

combustible walls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

5

Image 8
Contents Operators Manual For the User Retain this Manual for Your ReferenceTable of Contents Installation InspectionGeneral VentilationCleaning Installation ChecksElectrical WaterSpecification Drawing Tilting, KGL-40-T, KGL-60-T, KGL-80-T Short Series, KGL-40-SH, KGL-60-SH Short Series, KGL-40-TSH Operating Instructions Operating the Kettle Approximate Boiling TimesCleaning Instructions Care and CleaningService Parts Wrap CoversPressure Relief Assembly Item no Description QTYHinge Assembly Hinge Assembly KGL-40/TElectrical Component BOX Sight GlassTrunnion Assembly Tangent DRAW-OFF ValveGAS Control Assembly Stationary ModelsKE53441 BLOWER, 115V, 60 HZ Gearbox Assembly KE52836-2 Console Controls Potentiometer Used Prior to JanuaryMaintenance Inspection and Maintenance ChecklistKettle Safety Inspection Checklist Safety Thermostat Lubrication Procedure Hinge Adjustment InstructionsTroubleshooting Guides Problem KGL Problem Kettle Venting Vacuum Leak Test ProcedureRepairing Leaks in Steam Jacketed Kettle Fittings Reservoir Fill Procedures Kettle Jacket will Result in Irreversible Damage to UnitPressure Relief Valve Periodic Testing Calibrating ProcedureKettle Jacket Filling & Draining Procedures Recommended Corrosion Inhibitors for Closed SystemsGAS Kettle Orifice Replacement Replace Spring and Plug Replace Console CoverConversion Parts Required Wiring Diagrams Ignitor KE53838-2 KE53441-1 BLOWER, 220V, 50 HZ KE53838-2 Symbol Legend page 1 Symbol Legend page 2 Spare Parts List Part Number Description Quantity

KGL-40, KGL-60, KGL-80, KGL-100, KGL-40-T, KGL-60-T, KGL-80-T, KGL-40-SH, KGL-60-SH, KGL-40-TSH, KGL-100, KGL-40-T, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-80-T, KGL-40-SH specifications

Cleveland Range has established itself as a leading manufacturer of high-quality commercial kitchen equipment, particularly known for its diverse range of steamers. Among their notable offerings are the Cleveland Range KGL series models including KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, and KGL-60-T. These models are specifically designed to meet the needs of busy commercial kitchens, providing efficiency, durability, and precision in cooking.

The KGL-80-T model stands out with its generous cooking capacity, making it ideal for large-scale food preparation. It is equipped with advanced controls that allow for easy monitoring of cooking times and temperatures, ensuring that food is cooked evenly and to perfection. The integrated steaming technology maintains high levels of moisture, preserving the flavor and nutritional value of the food.

The KGL-40-SH and KGL-40-TSH models are tailored for mid-sized operations but still offer robust performance. These steamers incorporate user-friendly digital controls that facilitate hassle-free operation. The stainless-steel construction ensures durability and ease of cleaning, essential for maintaining hygiene in a busy kitchen environment.

Cleveland's KGL-40-T and KGL-40SH versions feature energy-efficient options, significantly reducing water and energy consumption without compromising on cooking quality. These models utilize a sophisticated water level management system that minimizes operational costs while maximizing cooking efficiency.

For establishments requiring even larger capacities, the KGL-100 model is an ideal solution, designed to cater to extensive foodservice operations. It boasts advanced steam generation technology, allowing for rapid heating and cooking. The ability to stack multiple trays enhances its functionality, making it a powerful tool for large events or high-demand services.

The KGL-60 and KGL-60-T models blend functionality with advanced features. The digital control panel provides precise steam control, time management, and temperature settings. Users can easily program multiple recipes, making it convenient to switch between different dishes quickly.

In summary, Cleveland Range's KGL series, including the KGL-80-T, KGL-40-SH, KGL-40-TSH, KGL-40, KGL-40-T, KGL-40SH, KGL-100, KGL-60, KGL-80, KGL-60-T, and others, epitomize excellence in commercial kitchen technology. With their commitment to quality, durability, and energy efficiency, these steamers are designed to enhance the culinary capabilities of any kitchen, ensuring that chefs can deliver exceptional meals consistently. Each model in the KGL series is tailored to meet the diverse needs of foodservice operations, from small restaurants to large catering businesses, ensuring optimal performance and reliability.