WhisperKool PLATINUM 8000, PLATINUM 4000 owner manual Frame the hole with two-by-four supports

Page 13

Once the horizontal lines have been cut, make verti- cal cuts using the inside edge of the studs as a guide. Once you have made both vertical cuts, you should have a rectangular hole in the sheetrock. Now you have to make the same hole on the other side of the wall. Since you already have one hole, this is an easy process. Using a nail, mark all four corners of the first hole by making nail holes through the sheetrock. Then on the other side of the wall, connect the holes with a pencil mark and cut.

Sheetrock alone cannot support the weight of a

65-pound (or more) cooling system. Therefore, it is necessary to frame the hole that you have just cut with upper and lower supports.

Using two 2x4s at 14.5” in length and eight 6d nails, secure the upper and lower supports to the right and left studs, just inside the sheetrock. Make sure that the internal height remains at 16” so that the WhisperKOOL system will fit snugly through the framed cut-out.

Frame the hole with two-by-four supports

Page 13

Image 13
Contents Platinum 8000ti ForPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide FAN Speed Reference Controller Quick Reference GuideModel Platinum 8000ti IntroductionReview the Packing Slip to Verify Contents Customer Warranty RegistrationCheck the Accessory Kits for the following contents Receiving & Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarInsulation Vapor Barrier Mounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Outlet InstallationMounting Flange Pieces THROUGH-THE-WALL Installation without ductworkLiquid Measuring Thermostat System Placement of UnitLocation of Supply and Return Grilles Do notDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsCold Air to/from Wine Cellar Ducted InstallationDucted Installation Insulation Box Condenser Exhaust Cold Air Standard Ducted InstallationIntake Return AirAdjacent Room Adjacent Room Wine CellarReturn Air-Cellar Side SideTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Only on the 8000ti Variable Speed ControlSystem Operation Standard & Remote Button Normal Functions Control Panel Features and OperationCpsm Alarm Codes Maintenance Schedule Unit does not run/power up Possible Cause Solution Troubleshooting GuideCellar Temperature is to Warm Possible Cause Solution Unit runs but does not cool Possible Cause Solution Unit leaks water Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionContact WhisperKOOL Customer Service Accessories for Cooling UnitsTechnical Assistance WhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage WhisperKOOL