INSTALLATION OPTIONS

Exterior Grille Installation

The exterior grille is required on all installations where the condenser side of the unit is exposed to the outside of the dwelling (i.e. rain and weather).

The Condenser Grille must be removed.

STEP 1:

Locate the screws at the bottom of the grille and remove. Using medium force, push the grille upward and lift the grille away from the unit.

STEP 2:

Remove Filter from Condenser Grille and place inside the Exterior Grille to protect the coils.

STEP 3:

Now determine at what depth the unit will be installed:

For a non-flush installation (i.e. holes location #1 WhisperKOOL retrofit or #2 Middle Wall), place the grille on the condenser end and line up the holes on the grille with the holes on unit location #3. Use the 10 self tapping screws provided to fasten the grille to the unit.

For a flush installation, place the grille on the condenser side and then place the mounting bracket over the grille sides, “stacking” them. Align the holes and fasten with the 10 self-tapping screws provided.

* It is required to use self tapping screws provided. Do not drill screws into unit.

Non-Flush Installation

Flush Installation

Page 18

PT-EXPL 020111

Image 18
Contents For Platinum 8000tiPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide Controller Quick Reference Guide FAN Speed ReferenceIntroduction Model Platinum 8000tiCheck the Accessory Kits for the following contents Customer Warranty RegistrationReview the Packing Slip to Verify Contents Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarWall & Ceiling Framing Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical OutletTHROUGH-THE-WALL Installation without ductwork Mounting Flange PiecesLocation of Supply and Return Grilles Placement of UnitLiquid Measuring Thermostat System Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationDucted Installation Cold Air to/from Wine CellarDucted Installation Intake Standard Ducted InstallationInsulation Box Condenser Exhaust Cold Air Return AirReturn Air-Cellar Side Adjacent Room Wine CellarAdjacent Room SideLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Variable Speed Control Only on the 8000tiSystem Operation Standard & Remote Control Panel Features and Operation Button Normal FunctionsCpsm Alarm Codes Maintenance Schedule Troubleshooting Guide Unit does not run/power up Possible Cause SolutionCellar Temperature is to Warm Possible Cause Solution Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionAccessories for Cooling Units Contact WhisperKOOL Customer ServiceTechnical Assistance Installation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage WhisperKOOL