SYSTEM OPERATION: STANDARD & REMOTE

Initial Start-Up

When power is applied to the unit, the control will briefly display all symbols, and the Compressor sym- bol will be displayed (if unit is calling for cooling). There may be a brief delay prior to the evaporator and condenser fans turning on, as the fans will not turn on until the sensors reach their perspective start tem- peratures (below 70°F for the evaporator and above 80°F for the condenser). When the condenser fan is activated the “AUX” symbol will turn off, and when the evaporator fan is activated the “FAN” symbol will turn on. The temperature control feature for the evapora- tor fan is a feature applicable to Whisperkool Advance Product Safety Technology (APST), which ensures that in the possible event of a cooling deficiency, the heat from the indoor fan will not raise the heat of the wine cellar, which could otherwise have an adverse effect on the wine aging process. After the indoor coil reaches a temperature below 70°F, the indoor fan symbol will be displayed and the fan will turn on. Note: For remote system condenser fan cycles with the compressor, the “Aux” symbol does not apply.

Normal System Cycle

After the bottle probe has reached the set point (all units are shipped with the set point of 55°F and a dif- ferential of 1°F), the compressor and the condenser fan will turn off, but the indoor fan will continue to run for about 5 minutes, 1 minute off until the unit gets a call for cooling which is a feature of the WhisperKOOL Humidity Management (WHM) system. The WHM is an adjustable feature which allows the customer the convenience of managing the humidity enhancement of their wine cellar. The WHM is one of the many Cus- tomer Preference Selection features which allow the customer the ability to fine tune the controls.

Anti Short Cycle

The Anti Short Cycle ensures that the compressor will remain off for a period of 5 minutes after the unit has reached the set point to allow the pressure in the refrigeration system to equalize prior to starting the compressor.

Defrost Cycle

The Defrost Cycle is a precautionary measure, as icing or frosting of the coil does not occur during normal operation. The system will go through a defrost cycle every 4 hours. During the defrost cycle, the indoor fan will provide air flow across the indoor coil, which will evaporate any frost accumulation.

Low Ambient Conditions

If the unit is installed in a Through-The-Wall applica- tion (which will allow the condenser to be exposed to low ambient temperatures), the condenser fan may cycle on and off. The purpose of the fan cycling is to maintain the system high side pressure, which will ensure an adequate refrigeration process. The fan cy- cling process is accomplished by way of a temperature probe attached to the condenser coil.

Note: Remote control systems do not use condenser fan cycling.

Bottle Probe Failure Protection

In the event that a bottle probe should fail, the APST (Advance Product Safety Technology) will automati- cally transition the Refrigeration Compressor cycles to a pre-determined time series (based on detailed laboratory testing), which will ensure that the product is kept within the safe range.

Remote Control Panel (optional)

The control panel can be installed or mounted sepa- rately from the cooling unit itself (remotely), using the supplied cable. This option provides unique flexibility for installing the Extreme Series cooling unit in your wine cellar. The remote option must be specified when the unit is ordered.

Note: Remote Control is generally standard with a “Ducted Unit”

Ducting and Ventilation Options

The ventilation system is ideal for ducting. The option- al collars fit standard ventilation ducting allowing the installer to vent air to and from the unit for optimum performance (please see specifications for details).

Page 27

Image 27
Contents Platinum 8000ti ForPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide FAN Speed Reference Controller Quick Reference GuideModel Platinum 8000ti IntroductionReceiving & Inspecting the Unit Customer Warranty RegistrationReview the Packing Slip to Verify Contents Check the Accessory Kits for the following contentsQuick Start Guide Vapor Barrier Preparing the Wine CellarWall & Ceiling Framing InsulationMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Outlet InstallationMounting Flange Pieces THROUGH-THE-WALL Installation without ductworkDo not Placement of UnitLiquid Measuring Thermostat System Location of Supply and Return GrillesDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsCold Air to/from Wine Cellar Ducted InstallationDucted Installation Return Air Standard Ducted InstallationInsulation Box Condenser Exhaust Cold Air IntakeSide Adjacent Room Wine CellarAdjacent Room Return Air-Cellar SideTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Only on the 8000ti Variable Speed ControlSystem Operation Standard & Remote Button Normal Functions Control Panel Features and OperationCpsm Alarm Codes Maintenance Schedule Troubleshooting Guide Unit does not run/power up Possible Cause SolutionCellar Temperature is to Warm Possible Cause Solution Compressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionAccessories for Cooling Units Contact WhisperKOOL Customer ServiceTechnical Assistance WhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage WhisperKOOL