WhisperKool PLATINUM 4000 Liquid Measuring Thermostat System, Placement of Unit, Do not

Page 16

Placement of Unit

Slide the unit from either the inside or outside wall into your wine cellar with the outer flange flush to the wall. You will need to reverse the mounting flange depending on inside or outside use. Secure the flange to the wall through the pre-drilled holes. The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL system (see illustration). Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.

Note: If you use decorative molding, it should be attached to the walls and never to the cooling unit itself.

Note: The screws to the flange should not be cover in case the unit will need to be removed for servicing.

2x4 Upper Support

Wall Stud

Mounting Flange

Back of unit

2x4 Lower Support

Drain Port

Electrical Outlet

Location of Supply and Return Grilles

Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room. Avoid short circulation of the air.

Do not:

Install through-the-wall return air grilles at floor level, as they will collect dust from the floor.

Mount the unit lower than 18” from the top of the room.

Locate the supply or return air grille where it is blocked by bottles, boxes or cases.

Liquid Measuring Thermostat System

To assure a consistent temperature, place bottle probe approximately 3 feet away from the air output and not in the flow of the air.

Page 16

PT-EXPL 020111

Image 16
Contents For Platinum 8000tiPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide Controller Quick Reference Guide FAN Speed ReferenceIntroduction Model Platinum 8000tiCustomer Warranty Registration Review the Packing Slip to Verify ContentsCheck the Accessory Kits for the following contents Receiving & Inspecting the UnitQuick Start Guide Preparing the Wine Cellar Wall & Ceiling FramingInsulation Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical OutletTHROUGH-THE-WALL Installation without ductwork Mounting Flange PiecesPlacement of Unit Liquid Measuring Thermostat SystemLocation of Supply and Return Grilles Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationDucted Installation Cold Air to/from Wine CellarDucted Installation Standard Ducted Installation Insulation Box Condenser Exhaust Cold AirIntake Return AirAdjacent Room Wine Cellar Adjacent RoomReturn Air-Cellar Side SideLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Variable Speed Control Only on the 8000tiSystem Operation Standard & Remote Control Panel Features and Operation Button Normal FunctionsCpsm Alarm Codes Maintenance Schedule Unit does not run/power up Possible Cause Solution Troubleshooting GuideCellar Temperature is to Warm Possible Cause Solution Unit leaks water Possible Cause Solution Unit runs but does not cool Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionContact WhisperKOOL Customer Service Accessories for Cooling UnitsTechnical Assistance Installation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage WhisperKOOL