VARIABLE SPEED CONTROL

(only on the 8000ti)

Designed for wine cellars from 1000 to 2000 cubic feet, the Extreme 8000ti features variable-speed fans with a “high” setting for maximum performance in high-temperature (+110°F) environments and a “low” setting for super-quiet operation.

Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3 speed settings: Low, Medium, and High. For optimum sound and energy efficiency, select the lowest fan speed that will maintain the desired cellar temperature. High speed is recommended for initial cellar cool down, extreme temperature conditions and ducted installations.

SET

Page 26

PT-EXPL 020111

Image 26
Contents For Platinum 8000tiPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide Controller Quick Reference Guide FAN Speed ReferenceIntroduction Model Platinum 8000tiCheck the Accessory Kits for the following contents Customer Warranty RegistrationReview the Packing Slip to Verify Contents Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarWall & Ceiling Framing Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical OutletTHROUGH-THE-WALL Installation without ductwork Mounting Flange PiecesLocation of Supply and Return Grilles Placement of UnitLiquid Measuring Thermostat System Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationDucted Installation Cold Air to/from Wine CellarDucted Installation Intake Standard Ducted InstallationInsulation Box Condenser Exhaust Cold Air Return AirReturn Air-Cellar Side Adjacent Room Wine CellarAdjacent Room SideLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Variable Speed Control Only on the 8000tiSystem Operation Standard & Remote Control Panel Features and Operation Button Normal FunctionsCpsm Alarm Codes Maintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Troubleshooting GuideUnit does not run/power up Possible Cause Solution Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Installation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage WhisperKOOL