WhisperKool PLATINUM 8000 THROUGH-THE-WALL Installation without ductwork, Mounting Flange Pieces

Page 15

THROUGH-THE-WALL INSTALLATION (without ductwork)

Mounting Flange Pieces

There are four individual pieces located in Kit 2 of your enclosed accessory kits. These flange pieces are de- signed to be used on the backside of the Extreme Series to mount to the exterior wall. There are three punch- outs located on the exterior of the housing. The punch-outs are designed for specific through-the-wall installa- tion mounts. Please refer to the illustration for location of the punch-outs.

#1. Retrofit your current WhisperKOOL cooling unit

#2. Middle wall installation

#3. Flush mount to exterior wall

Back of unit

Applying Insulation Tape Locate the four precut pieces of black foam tape included with the system. There should be two larger pieces and two smaller pieces. Once you have attached the flange pieces to the unit, peel back the white- paper adhesive covering and place on the corresponding size of flange. The large pieces are applied to the top and bottom of the unit and the smaller pieces to the right and left side flanges. This foam creates a tight seal between the flange and the wall.

Front of unit

Page 15

Image 15
Contents Platinum 8000ti ForPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide FAN Speed Reference Controller Quick Reference GuideModel Platinum 8000ti IntroductionReceiving & Inspecting the Unit Customer Warranty RegistrationReview the Packing Slip to Verify Contents Check the Accessory Kits for the following contentsQuick Start Guide Vapor Barrier Preparing the Wine CellarWall & Ceiling Framing InsulationMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Outlet InstallationMounting Flange Pieces THROUGH-THE-WALL Installation without ductworkDo not Placement of UnitLiquid Measuring Thermostat System Location of Supply and Return GrillesDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsCold Air to/from Wine Cellar Ducted InstallationDucted Installation Return Air Standard Ducted InstallationInsulation Box Condenser Exhaust Cold Air IntakeSide Adjacent Room Wine CellarAdjacent Room Return Air-Cellar SideTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Only on the 8000ti Variable Speed ControlSystem Operation Standard & Remote Button Normal Functions Control Panel Features and OperationCpsm Alarm Codes Maintenance Schedule Troubleshooting Guide Unit does not run/power up Possible Cause SolutionCellar Temperature is to Warm Possible Cause Solution Compressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionAccessories for Cooling Units Contact WhisperKOOL Customer ServiceTechnical Assistance WhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage WhisperKOOL