MAINTENANCE SCHEDULE

Monthly 1. Check filters

2.Check for unusual noise or vibration

3.Check the drainline to see if it is above the waterline if draining into a vessel.

Quarterly Clean filters:

1.Remove grille/ducting on both ends of unit.

2.Remove the filter covering the coil.

3.Wash with warm water

4.Dry off filter by shaking excess water from filter.

Annually 1. Replace filters if worn or plugged beyond cleaning.

2.Use a vacuum with brush attachment to clean coils. Be careful not to crush coil fins when cleaning.

3.Inspect for corrosion.

4.Check wiring connections and integrity of cords.

5.Examine duct work for cracks or possible leaks.

6.Pour a 50/50 bleach solution into the drainline every spring.

Page 31

Image 31
Contents Platinum 8000ti ForPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide FAN Speed Reference Controller Quick Reference GuideModel Platinum 8000ti IntroductionReceiving & Inspecting the Unit Customer Warranty RegistrationReview the Packing Slip to Verify Contents Check the Accessory Kits for the following contentsQuick Start Guide Vapor Barrier Preparing the Wine CellarWall & Ceiling Framing InsulationMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Outlet InstallationMounting Flange Pieces THROUGH-THE-WALL Installation without ductworkDo not Placement of UnitLiquid Measuring Thermostat System Location of Supply and Return GrillesDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsCold Air to/from Wine Cellar Ducted InstallationDucted Installation Return Air Standard Ducted InstallationInsulation Box Condenser Exhaust Cold Air IntakeSide Adjacent Room Wine CellarAdjacent Room Return Air-Cellar SideTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Only on the 8000ti Variable Speed ControlSystem Operation Standard & Remote Button Normal Functions Control Panel Features and OperationCpsm Alarm Codes Maintenance Schedule Unit does not run/power up Possible Cause Solution Troubleshooting GuideCellar Temperature is to Warm Possible Cause Solution Compressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionContact WhisperKOOL Customer Service Accessories for Cooling UnitsTechnical Assistance WhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage WhisperKOOL