WhisperKool PLATINUM 8000, PLATINUM 4000 owner manual Condensation Drain Line Tube

Page 17

Condensation Drain Line Tube

The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess condensation.

Failure to use the condensation drain line tube will void the warranty on the unit.

Drain Line

T-Fitting

Drain Line

All units come with a drain line for additional removal of excessive condensate. It is mandatory to install the drain line attachment. During operation, the cooling unit will strip excess water from the air in order to maintain the proper level of humidity within the cellar. However in extreme humidity, additional condensate will be created. Conversely the high humidity air has less capacity to absorb additional moisture through the exhaust of the unit. Thus the drain line will prevent overflow and leaking by allowing for discharge of the additional condensate.

Failure to install the drain line voids warranty.

To prevent mold from growing, allow the drainline to hang above the water line.

WRONG: Drainline is under water.

Page 17

Image 17
Contents Platinum 8000ti ForPT-EXPL Table of Contents Whisperkool Series Quick Reference Guide FAN Speed Reference Controller Quick Reference GuideModel Platinum 8000ti IntroductionReview the Packing Slip to Verify Contents Customer Warranty RegistrationCheck the Accessory Kits for the following contents Receiving & Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarInsulation Vapor BarrierMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Outlet InstallationMounting Flange Pieces THROUGH-THE-WALL Installation without ductworkLiquid Measuring Thermostat System Placement of UnitLocation of Supply and Return Grilles Do notDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsCold Air to/from Wine Cellar Ducted InstallationDucted Installation Insulation Box Condenser Exhaust Cold Air Standard Ducted InstallationIntake Return AirAdjacent Room Adjacent Room Wine CellarReturn Air-Cellar Side SideTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Only on the 8000ti Variable Speed ControlSystem Operation Standard & Remote Button Normal Functions Control Panel Features and OperationCpsm Alarm Codes Maintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Troubleshooting GuideUnit does not run/power up Possible Cause Solution Unit runs but does not cool Possible Cause Solution Unit leaks water Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service WhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage WhisperKOOL