U-Line Ice Maker Error Codes: Understanding CLR2160, CL & P1 Errors

Page 16

Section 3 - Service and Repair

OPERATION

CLR2160

GENERAL

Upon initial startup, this unit will enter mode number 5 which is a three-minute water fill regardless of the thermistor temperatures. This only occurs when the initial startup is caused by a power-up of the main board.

Following the three-minute water fill, the unit moves into mode 1 which is the freezing mode. In this mode the water is pumped from the sump trough over the ice maker grid by the circulation pump. This mode typically lasts 10-20 minutes and is regulated by the temperature of the thermistor mounted near the dryer (thermistor 4).

At the conclusion of the freeze cycle the unit will enter mode 2 which is the ice harvest. This harvest can last up to three minutes. During this mode the water trough also refills.

Before the next cycle begins, the custom electronic board determines whether the bin is full. A temperature below 34°F, or a temperature below 35°F for at least one hour will stop the unit from producing ice. The ice-making will always stop at the conclusion of a harvest cycle. It will never stop in the middle of a cycle.

The custom electronic board continuously monitors the optional P60 pump to ensure the drain line is not becoming restricted. In the event of a drain line obstruction, the display interface will show “P1.” If the drain remains restricted the unit will stop ice production until the drain clears. In the event of a partially restricted drain, reduced ice rate will be noticed as the unit continuously turns on and off to eliminate any chances of overfilling the unit with water. If no pump is used the pink jumper needs to be connected to the power cord in its place.

A cleaning mode is available through the user interface by using the key sequence described in the Controls Section. The cleaning mode lasts about 45 minutes, at which point the unit will sit idle for another 15 minutes. During this time the display will show “CL.” At the conclusion of the cycle the unit will automatically turn back on.

THERMISTOR OUTAGE

In the event that a thermistor fails, the unit will stop all functions and display “ER” on the user interface. The exact error can be accessed via the service mode.

SERVICE

The CLR2160 model uses four relays and two thermistors. There is a variety of built-in servicing features to aid in diagnosing the root problem associated with a unit.

To check to see which relays are currently operating, hold the COLDER key and press the ON/OFF key three times. When

entering the sequence, keep the COLDER key pressed until you completely release the ON/OFF key for the third time. The display will cycle through a series of numbers to tell which relays are energized. For example, if the unit was in ice-making mode the display would show 11 20 31 40 51 60 70. The first number is the relay number. In the second number, “1” means on and “0” means off. The relay information can be found in the Control Section.

Each relay can also be turned on and off individually to determine whether or not the board and component are operating. If a board is suspected of not operating correctly you can run through this sequence to ensure each component is turning on and off through the board correctly. Go into service mode and choose option #22. This will cycle every relay on and off showing 10 11 20 21 …. If a

component fails to turn on when the relay does, you can verify if there is voltage present by using a voltmeter to check the board output.

To view the actual thermistor readings, hold the WARMER and COLDER keys for about five seconds. The display will cycle through the three thermistors and their temperatures. If a thermistor is unused in a unit it will show a “0” reading. The CLR2160 uses thermistors 2 and 4. For thermistor 4 the display will only show up to “99.” In the event the temperature is higher than this the display will show a flashing “99.”

TROUBLESHOOTING

Error Codes

E1, E2, E9

Bad thermistor errors. Replace thermistor. Check

 

for thermistor errors by accessing “View thermistor

 

# status (2,19, 20, or 21).” If the error code is

 

repeated, the thermistor is open or shorted. If a

 

temperature is displayed, the thermistor is not

 

defective.

P1

Pump circuit is detecting a drain problem. Consult a

 

plumber to resolve the issue. If unit does not have a

 

P60 installed, then the jumper wire is missing in

 

place of the pump.

Any other error messages will not affect the operation of the CLR2160 model.

After checking the errors be sure to clear the error log by performing service option 12

3-1

Image 16
Contents 2010 Potential Problems with HFC-134A IntroductionÉchelon Models 2115R Origins Models 1115RTable of Contents Wiring Diagrams Safety Precautions Safety Alert DefinitionsLine Corporation Limited Warranty Product Liability Policy Leaders In Quality Undercounter RefrigerationSerial Number Format Warranty Claims ProcedureProof of Purchase Parts Listing How to Order Replacement PartsCustomer Call Guide CLR2160 Model Only Type 1 Black Refrigeration System Diagnosis GuideType 2 White Troubleshooting Troubleshooting Troubleshooting Error Codes ServiceOperation GeneralCLR2160 No ice Too much iceToo little ice Ice not sized to customer satisfactionCLRCO2175 CLRCO2175 Mode 1 Ice Making and Refrigeration ULIN0329A CLRCO2175 Mode 3 Refrigeration and No Ice Making CLRCO2175 Mode 4 Ice harvest No Refrigeration Possible CLRCO2175 Mode 5 Off Service and Repair CLRCO2175 Mode 7 Cleaning No Refrigeration Possible Error code is repeated, the thermistor is Refrigerator not cooling but ice maker working Display is showing something other than SP 38, ER or CLIce maker not operating-no water flowing over mold 2115R/2175WC/2175BEV/2275DWRR/2175DWRR Thermistor Outage Except Dwrws & 2275ZWC Review the Following Notes for General InformationThermistor Outage Dwrws & 2275ZWC Display is showing something other than SP 38 or ER Excessive Frost on evaporatorRefrigerator too warm Service and Repair CO2175F/2175RF/CO2175DWR Line Frost Free Refrigeration SystemThermistors Reed SwitchDefrost Storage mode Freeze cycleHarvest cycle Water fill cycleCO2175F Harvest-1 Cycle First 30 Seconds CO2175F Water Fill Cycle CO2175F Freeze Cycle CO2175/2275DWR Harvest-2 Cycle After 30 Seconds CO2175/2275DWR Water Fill Cycle Not making ice This can be caused by poor incoming water quality Service and Repair 1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Error Code It is most likely a refrigeration system issueOperating ENVIRONMENTAL/ Climate Control Requirements Échelon Electronic ControlON/OFF Cabinet LightAdjusting the SET-POINT 2275ZWC/2275ZWCOL only Adjusting the SET-POINT 2275DWRWS only2275ZWCOL Viewing Actual Temperature 2275DWRWS only Viewing Actual Temperature 2275ZWC/2275ZWCOL onlyShowroom Mode Service ModeICE Thickness Adjust Temporary SHUTDOWN/OFFICE ModeForced Defrost Relay StatusError Codes E2 Thermistor 1 is shorted. Not available on CLR2160 Model Thermistor Door Switch Échelon Service Quick Reference Card Échelon Electronic Control Quick Reference Guide Viewing Actual Temperature Origins Electronic ControlOrigins Service Menu Origins Model SelectionOrigins Electronic Control Quick Reference Guide Defrost Information ALL Models Refrigeration System Diagnosis GuideSpecifications COMPRESSOR/COIL SpecificationsCLRCO2175 Refrigerator Coil OHMS-2175DWRWS/2275ZWC 2115R/2175WC/2115WC/2175BEV 2175WRR/2175DWRWSICE Maker Limit Switch CO2175F/2175RF/CO2175DWR1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Adjustments and Repair Échelon Full OverlayAdjusting Door Alignment Notch must face center of doorDoor Alignment Origins Models Checking Door AlignmentChecking Drawer Alignment Adjusting Drawer AlignmentDrawer Removal Minor Adjustment Severe AdjustmentSIDE-TO-SIDE Adjustment FRONT-TO-BACK AdjustmentTOP-TO-BOTTOM and LEFT-TO-RIGHT Adjustment RE-INSTALLATION of Drawer Ice Cube Thickness Adjustment Interval AS RequiredAccessing Evaporator or Drain CO2175F/2175RF Replacing Evaporator FAN Motor CO2175F/2175RFTo access evaporator or drain Replacing Evaporator FAN Motor CO2175DWRReplacing ICE Maker Replacing Mold and Heater CO2175F/CO2175DWR Drain Connection FACTORY-INSTALLED Drain PumpGravity Drain Remove 12 screws and back panel LOCALLY-INSTALLED Drain Pump Tools RequiredMaterials Required CLR Drain KIT Available for PurchaseULINS0168A Loose. For the disposal or Water Supply Connection WaterhookupANTI-TIP KIT CLR2160 1 Description CLR2160 2 41993 CLRCO2175 1 Screw, handle included with handle assembly CLRCO2175 2 Compression nut included with water line CLRCO2175 3 Armaflex, 1-5/8 ID included with 2276-CLRCO-S CLRCO2175 4 BF4CO5-S 2175R 1 Screw, handle included with handle assembly 2175R 2 Not 2950-01 Wire connector, 12-pin 2115R 1 Screw, handle included with handle assembly 2115R 2 41993 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL /2175WCOL22 Black Stainless Steel 2115WC/2115WCOL/2115WCOL2 1OF2 2115WC/2115WCOL/2115WCOL2 1 2115WC/2115WCOL/2115WCOL2 2 41993 2175BEV/2175BEVOL/2175BEVOL2 1 Overlay Door Stainless Steel 2175BEV/2175BEVOL/2175BEVOL2 2 Black Stainless Steel 2175DWRR/2275DWRR 1 2175DWR-TOP-BLK 2175DWRR/2275DWRR 2 Not 14159-05 Commerical handle SS accesory only 2275DWRWS/2275DWRWOL 1 Not 80-50002-00 Overlay Bracket Assembly 2275DWRWS/2275DWRWOL 2 Item Part No. Description CO2175F 1 Description CO2175F 2 0f CO2175F 2 CO2175F 3 Not 35014 Tape, drain pan heater CO2175F 4 Mold and Heater Assembly 2175RF 1 Black White Stainless Steel 2175RF 2 Solenoid only included with 73002-FFS 2175RF 3 Evaporator Assembly includes heat exchanger CO2175DWR/CO2275DWR 1 Process tube included with 73002-FFS CO2175DWR/CO2275DWR 2 Drawer Front Assembly, top CO2175DWR/CO2275DWR 3 Evaporator Assembly includes heat exchanger CO2275DWR 4 Mold and Heater Assembly 2275ZWC/2275ZWCOL 1 Overlay Stainless Steel 2275ZWC/2275ZWCOL 2 Process tube included with compressor 2275ZWC/2275ZWCOL 3 26100 Display housing 41992 1175R 1 Towel Bar Handle Assembly SS accessory only 1175R 2 Thermistor, quick connect white 1115R 1 Black Stainless Steel 1115R 2 31213 Spacer 1175WC 1 26147 Door Spacer, for Field Reversable Doors 1175WC 2 26058 1115WC 1 Pivot screw, bottom included with hinge assembly 1115WC 2 26059 1175BEV 1 26147 Door Spacer, for Field Reversable Doors 1175BEV 2 26058 ADA24R 1 0F ADA24R 1 0F DescriptionADA24R 2 0F Description Black Stainless Steel This page intentionally left blank CLRCO2175 2115R, 2115WC, 2175R, 2175WC, 2175BEV 2175RF CO2175F ADA24R This page intentionally left blank Product Information About U-LINE
Related manuals
Manual 2 pages 56.41 Kb Manual 20 pages 47.95 Kb Manual 24 pages 22.01 Kb Manual 24 pages 59.37 Kb Manual 2 pages 14.55 Kb Manual 24 pages 53.32 Kb Manual 28 pages 19.37 Kb Manual 28 pages 10.67 Kb Manual 24 pages 54.3 Kb

2175R, 2115R, 2115WC, 2175/2275DWRR, 2115WCOL specifications

The U-Line CLRCO2175 and CLR2160 are standout models in the world of compact refrigeration solutions, offering remarkable features tailored for modern living. Known for their slim design and efficient performance, these models are perfect for homeowners seeking added convenience without sacrificing space or style.

The U-Line CLRCO2175 boasts a capacity of 5.3 cubic feet, providing ample storage while maintaining a sleek profile. Its glass door is a key highlight, featuring Low-E argon gas-filled glass which not only enhances visibility but also provides energy efficiency by minimizing heat transfer. The model includes a built-in ice maker, delivering a continuous supply of fresh ice, which is ideal for entertaining or everyday use.

On the other hand, the CLR2160 offers a slightly smaller capacity of 3.4 cubic feet, perfectly suited for tighter spaces while still delivering on performance. It features the same stylish glass door and energy-efficient insulation, ensuring that your favorite beverages and snacks are kept at optimal temperatures.

Both models are equipped with a digital control panel that allows for precise temperature adjustments, catering to the specific needs of various items from wine to soft drinks. The internal shelving is adjustable, making it easy to customize the interior configuration to accommodate different bottle shapes and sizes.

Energy efficiency is a driving consideration in these models, as they are designed to consume less power compared to traditional refrigerators. This not only helps in reducing utility bills but also minimizes the environmental impact. Furthermore, U-Line has implemented noise-reducing technologies, ensuring quiet operation—ideal for placement in living spaces or open floor plans.

The sleek aesthetic of the CLRCO2175 and CLR2160 can seamlessly blend into various decor styles, from contemporary to traditional. With their stainless-steel finishes and elegant edge-to-edge glass doors, they serve not just as appliances but also as stylish additions to home interiors.

In conclusion, the U-Line CLRCO2175 and CLR2160 offer exceptional features and technologies tailored for modern living. Their space-saving designs, energy-efficient performance, and stylish aesthetics make these models essential choices for those looking to enhance their home with versatile refrigeration solutions. Whether entertaining guests or enjoying a quiet evening at home, these appliances provide the reliability and functionality needed in today’s fast-paced lifestyle.