U-Line Understanding Ice Maker Error Codes and Thermistor Outages

Page 40

Section 3 - Service and Repair

THERMISTOR OUTAGE

If the refrigerator thermistor (T1) fails, the unit will continue to operate based on the freezer temperature. Cycle lengths and temperatures may not be exact; however, this will prevent the loss of perishables. The display will show “ER.” The exact error can be accessed via the service mode.

If the ice maker thermistor (T2) fails, the unit will operate except it will not produce ice. The display will show “ER.” The exact error can be accessed via the service mode.

If the freezer thermistor (T3) fails, the unit will continue to operate based on the refrigerator (T1) temperature. Cycle lengths and temperatures may not be exact; however, this will prevent the loss of perishables. The display will show “ER.” The exact error can be accessed via the service mode.

If the pan thermistor (T4) fails, the unit will operate normally; however, the defrost will take place on time only rather than time/ temperature. The display will show “ER.” The exact error can be accessed via the service mode.

SERVICE

To check to see which relays are currently operating, hold the COLDER key and press the ON/OFF key three times. When entering the sequence, keep the COLDER key pressed until you completely release the ON/OFF key for the third time. The display will cycle through a series of numbers to tell which relays are energized. For example, if the unit was in ice-making mode the display would show 11 20 31 40 51 60 70. The first number is the relay number. In the second number, 1 means ON and 2 means OFF. The relay information can be found in the Control Section.

Each relay can also be turned on and off individually to determine whether or not the board and component are operating. If a board is suspected of not operating correctly, you can run through this sequence to ensure each component is turning on and off through the board correctly. Go into service mode and choose option #22. This will cycle every relay on and off showing 10 11 20 21 …. If a

component fails to turn on when the relay does, you can verify if there is voltage present by using a voltmeter to check the board output.

To view the actual refrigerator (T1) temperature, hold the WARMER key until the actual temperature is displayed. To view the actual thermistor readings for 2-4, hold the WARMER and COLDER keys for about five seconds. The display will cycle through the three thermistors and their temperatures. If a thermistor is unused in a unit it will show a “0” reading.

In the general section the methods to enter some other service modes are available. For these models some useful modes are the ICE MAKER OFF MODE, FORCED ICE MAKER HARVEST, and FORCED REFRIGERATOR DEFROST. These can be useful in servicing the unit.

TROUBLESHOOTING:

Error Codes

E1, E2, E7, E8, E9

Bad thermistor errors. Replace thermistor.

 

Check for thermistor errors by accessing

 

“View thermistor # status (2, 19, 20, or 21).” If

 

the error code is repeated, the thermistor is

 

open or shorted. If a temperature is displayed,

 

the thermistor is not defective.

E3

This will be accompanied by a beep every

 

minute. This signals that the door (or bottom

 

drawer) has been left open for longer than 20

 

minutes. Close the door to reset. If the light

 

and display do not go off when the door is

 

closed check to make sure the magnet is

 

positioned properly.

E5

This signals that the unit has been above set-

 

point for more than twelve hours by at least 10

 

degrees. After repair is completed, leave for 24

 

hours to see if the problem is corrected. If it is

 

not corrected, it is most likely a refrigeration

 

system issue.

E6

This signals that the refrigerator section has

 

been at least 10 degrees below set-point for at

 

least twelve hours. This would most likely be

 

caused by a bad relay and the circuit board.

E10

This will be accompanied by a beep every

 

minute. This signals that the top drawer has

 

been left open for longer than 20 minutes.

Close the door to reset. If the light and display do not go off when the door is closed check to make sure the magnet is positioned properly.

After checking the errors be sure to clear the error log by performing service option 12.

Not making ice

The ice maker needs to be down to 15°F before initiating a harvest. If above 15°F, the unit is not cooling properly or has not been plugged in for a sufficient period of time.

The CO2175DWR model will only harvest ice with the lower drawer closed.

To check the operation of the circuit board and the ice maker, force an ice harvest through the keypad input. During this time you can check to see if the blades rotate, if they stop anywhere, if the water valve opens, etc.

3-25

Image 40 Contents
2010 Potential Problems with HFC-134A IntroductionÉchelon Models 2115R Origins Models 1115RTable of Contents Wiring Diagrams Safety Precautions Safety Alert DefinitionsLine Corporation Limited Warranty Product Liability Policy Leaders In Quality Undercounter RefrigerationSerial Number Format Warranty Claims ProcedureProof of Purchase Parts Listing How to Order Replacement PartsCustomer Call Guide CLR2160 Model Only Type 1 Black Refrigeration System Diagnosis GuideType 2 White Troubleshooting Troubleshooting Troubleshooting Error Codes ServiceOperation GeneralCLR2160 No ice Too much iceToo little ice Ice not sized to customer satisfactionCLRCO2175 CLRCO2175 Mode 1 Ice Making and Refrigeration ULIN0329A CLRCO2175 Mode 3 Refrigeration and No Ice Making CLRCO2175 Mode 4 Ice harvest No Refrigeration Possible CLRCO2175 Mode 5 Off Service and Repair CLRCO2175 Mode 7 Cleaning No Refrigeration Possible Error code is repeated, the thermistor is Refrigerator not cooling but ice maker working Display is showing something other than SP 38, ER or CLIce maker not operating-no water flowing over mold 2115R/2175WC/2175BEV/2275DWRR/2175DWRR Thermistor Outage Except Dwrws & 2275ZWC Review the Following Notes for General InformationThermistor Outage Dwrws & 2275ZWC Display is showing something other than SP 38 or ER Excessive Frost on evaporatorRefrigerator too warm Service and Repair CO2175F/2175RF/CO2175DWR Line Frost Free Refrigeration SystemThermistors Reed SwitchDefrost Storage mode Freeze cycleHarvest cycle Water fill cycleCO2175F Harvest-1 Cycle First 30 Seconds CO2175F Water Fill Cycle CO2175F Freeze Cycle CO2175/2275DWR Harvest-2 Cycle After 30 Seconds CO2175/2275DWR Water Fill Cycle Not making ice This can be caused by poor incoming water quality Service and Repair 1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Error Code It is most likely a refrigeration system issueOperating ENVIRONMENTAL/ Climate Control Requirements Échelon Electronic ControlON/OFF Cabinet LightAdjusting the SET-POINT 2275ZWC/2275ZWCOL only Adjusting the SET-POINT 2275DWRWS only2275ZWCOL Viewing Actual Temperature 2275DWRWS only Viewing Actual Temperature 2275ZWC/2275ZWCOL onlyShowroom Mode Service ModeICE Thickness Adjust Temporary SHUTDOWN/OFFICE ModeForced Defrost Relay StatusError Codes E2 Thermistor 1 is shorted. Not available on CLR2160 Model Thermistor Door Switch Échelon Service Quick Reference Card Échelon Electronic Control Quick Reference Guide Viewing Actual Temperature Origins Electronic ControlOrigins Service Menu Origins Model SelectionOrigins Electronic Control Quick Reference Guide Defrost Information ALL Models Refrigeration System Diagnosis GuideSpecifications COMPRESSOR/COIL SpecificationsCLRCO2175 Refrigerator Coil OHMS-2175DWRWS/2275ZWC 2115R/2175WC/2115WC/2175BEV 2175WRR/2175DWRWSICE Maker Limit Switch CO2175F/2175RF/CO2175DWR1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Adjustments and Repair Échelon Full OverlayAdjusting Door Alignment Notch must face center of doorDoor Alignment Origins Models Checking Door AlignmentChecking Drawer Alignment Adjusting Drawer AlignmentDrawer Removal Minor Adjustment Severe AdjustmentSIDE-TO-SIDE Adjustment FRONT-TO-BACK AdjustmentTOP-TO-BOTTOM and LEFT-TO-RIGHT Adjustment RE-INSTALLATION of Drawer Ice Cube Thickness Adjustment Interval AS RequiredAccessing Evaporator or Drain CO2175F/2175RF Replacing Evaporator FAN Motor CO2175F/2175RFTo access evaporator or drain Replacing Evaporator FAN Motor CO2175DWRReplacing ICE Maker Replacing Mold and Heater CO2175F/CO2175DWR Drain Connection FACTORY-INSTALLED Drain PumpGravity Drain Remove 12 screws and back panel LOCALLY-INSTALLED Drain Pump Tools RequiredMaterials Required CLR Drain KIT Available for PurchaseULINS0168A Loose. For the disposal or Water Supply Connection WaterhookupANTI-TIP KIT CLR2160 1 Description CLR2160 2 41993 CLRCO2175 1 Screw, handle included with handle assembly CLRCO2175 2 Compression nut included with water line CLRCO2175 3 Armaflex, 1-5/8 ID included with 2276-CLRCO-S CLRCO2175 4 BF4CO5-S 2175R 1 Screw, handle included with handle assembly 2175R 2 Not 2950-01 Wire connector, 12-pin 2115R 1 Screw, handle included with handle assembly 2115R 2 41993 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL /2175WCOL22 Black Stainless Steel 2115WC/2115WCOL/2115WCOL2 1OF2 2115WC/2115WCOL/2115WCOL2 1 2115WC/2115WCOL/2115WCOL2 2 41993 2175BEV/2175BEVOL/2175BEVOL2 1 Overlay Door Stainless Steel 2175BEV/2175BEVOL/2175BEVOL2 2 Black Stainless Steel 2175DWRR/2275DWRR 1 2175DWR-TOP-BLK 2175DWRR/2275DWRR 2 Not 14159-05 Commerical handle SS accesory only 2275DWRWS/2275DWRWOL 1 Not 80-50002-00 Overlay Bracket Assembly 2275DWRWS/2275DWRWOL 2 Item Part No. Description CO2175F 1 Description CO2175F 2 0f CO2175F 2 CO2175F 3 Not 35014 Tape, drain pan heater CO2175F 4 Mold and Heater Assembly 2175RF 1 Black White Stainless Steel 2175RF 2 Solenoid only included with 73002-FFS 2175RF 3 Evaporator Assembly includes heat exchanger CO2175DWR/CO2275DWR 1 Process tube included with 73002-FFS CO2175DWR/CO2275DWR 2 Drawer Front Assembly, top CO2175DWR/CO2275DWR 3 Evaporator Assembly includes heat exchanger CO2275DWR 4 Mold and Heater Assembly 2275ZWC/2275ZWCOL 1 Overlay Stainless Steel 2275ZWC/2275ZWCOL 2 Process tube included with compressor 2275ZWC/2275ZWCOL 3 26100 Display housing 41992 1175R 1 Towel Bar Handle Assembly SS accessory only 1175R 2 Thermistor, quick connect white 1115R 1 Black Stainless Steel 1115R 2 31213 Spacer 1175WC 1 26147 Door Spacer, for Field Reversable Doors 1175WC 2 26058 1115WC 1 Pivot screw, bottom included with hinge assembly 1115WC 2 26059 1175BEV 1 26147 Door Spacer, for Field Reversable Doors 1175BEV 2 26058 ADA24R 1 0F ADA24R 1 0F DescriptionADA24R 2 0F Description Black Stainless Steel This page intentionally left blank CLRCO2175 2115R, 2115WC, 2175R, 2175WC, 2175BEV 2175RF CO2175F ADA24R This page intentionally left blank Product Information About U-LINE