U-Line 2175WCOL Viewing Actual Temperature 2275DWRWS only, Changing from Fahrenheit to Celsius

Page 46

Section 3 - Service and Repair

VIEWING ACTUAL TEMPERATURE - 2275DWRWS ONLY

To view the temperature in the top and bottom drawer (T1 and T2), hold the WARMER key for five seconds until “°F” flashes. Release and the display will show the corrected temperatures of both zones on their respective displays. To view the temperature of T3 and T4, you must use the service mode.

VIEWING ACTUAL TEMPERATURE - 2275ZWC/2275ZWCOL ONLY

To display actual zone temperatures (not set-point):

1.Press and hold the WARMER icon for the desired zone for approximately five seconds until unit beeps, and release when the decimal in the display begins to flash (Figure 25).

2.The display will show the actual zone temperature.

3.After five seconds, the display will return to the set-point temperature.

 

 

UPPER ZONE CONTROLS

 

 

 

 

 

 

 

 

 

 

 

Power Warmer Cooler Display

 

 

Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display Warmer Cooler

 

 

 

 

 

 

 

 

LOWER ZONE CONTROLS

 

 

 

 

ULIN_1011_A

 

 

 

 

 

 

 

Figure 25. Displaying Zone Temperature

CHANGING FROM FAHRENHEIT TO CELSIUS

To change the displayed temperature from °F to °C, hold the LIGHT key and press the down arrow three times. This will change all values to °C. When the key combination is accepted the control will beep once and change values.

SHOWROOM MODE

This mode is designed to show units in a display environment. When in this mode the only functions will be the control and cabinet lights. The compressor, fans, etc. will not operate. To enter this mode hold the down arrow and press the LIGHT button three times. When entered, the unit will beep once and the degree symbol will begin to flash. When the degree symbol is flashing the unit will allow the use of the control for demonstrations.

On early models, after not touching the unit for one minute the display will begin to “snake” around. This is meant to alert you the unit is in showroom mode.

On later models, the degree (°) flashes.

The unit can be left in this mode indefinitely. If you again want to demo the control, touch any key and the degree symbol will begin to flash. To exit this mode: If using software version 2.8, this mode will exit automatically when the unit is unplugged. If using software version 2.9, this mode needs to be exited by the same key combination as used to enter the mode.

SERVICE MODE

This mode has 27 different options available for service diagnostics. To enter the mode hold the WARMER key and press the LIGHT

button three times. The display will show “0” and the board will beep once. When in this mode the WARMER and COLDER keys will act as up and down arrows to select the desired option. The LIGHT key is the ENTER key and will enter a function. If changing a function, you must press the LIGHT button again to retain the changed setting. To exit the service mode, scroll to option 99 and press the LIGHT key. After five minutes of not touching any keys the mode will also exit automatically.

DISPLAY TOGGLE

On glass door units the display normally stays on all the time. To have the display turn off with the door press the up arrow and touch the ON/OFF key three times. The °F sign will flash and the board will beep once to let you know the mode has been accepted. This mode can be toggled on or off by the same key combination. To see if the display should be staying on 100% or turning off with the door, you can check service option 8. Only available on 2115WC, 2175W, 2275DWRWS, 2175BEV, 2275ZWC & 2275ZWCOL.

BLACKOUT MODE

Hold the LIGHT key for 10 seconds until the °F starts flashing. When released, the unit will beep once and the display and cabinet light will shut off. To cancel this mode, hold the LIGHT key again for about 10-12 seconds.

CLEAN CYCLE

To enter the self-cleaning cycle hold the ON/OFF key and press the light three times. The unit will beep once and the display will show CL. Follow the cleaning instructions. At the conclusion of this mode (1 hour) the display will revert to set-point and the unit will resume normal operation. To cancel this mode turn the unit off via the keypad. Only available on CLR2160 and

CLRCO2175.

ICE MAKER OFF MODE

This mode will stop ice production. To enter hold the ON/OFF key and press the up arrow three times. The unit will beep once when the mode is entered. After 5-10 seconds the display will start to scroll from “SP” to “Ice” to “Off” as long as the mode is active. To exit either turn the unit off via keypad or do the same key combination. Only available on CO2175F, CLRCO2175 and

CO2175DWR.

FORCED HARVEST

This mode can be used to force ice to harvest from the mold. To enter this mode hold LIGHT key and press the up arrow three times. The unit will initiate an ice harvest. There is no audible tone when entering this mode. Only available on CO2175F and

CO2175DWR.

3-31

Image 46 Contents
2010 Échelon Models 2115R Potential Problems with HFC-134AIntroduction Origins Models 1115RTable of Contents Wiring Diagrams Safety Precautions Safety Alert DefinitionsLine Corporation Limited Warranty Product Liability Policy Leaders In Quality Undercounter RefrigerationSerial Number Format Warranty Claims ProcedureProof of Purchase Parts Listing How to Order Replacement PartsCustomer Call Guide CLR2160 Model Only Type 1 Black Refrigeration System Diagnosis GuideType 2 White Troubleshooting Troubleshooting Troubleshooting Operation Error CodesService GeneralCLR2160 Too little ice No iceToo much ice Ice not sized to customer satisfactionCLRCO2175 CLRCO2175 Mode 1 Ice Making and Refrigeration ULIN0329A CLRCO2175 Mode 3 Refrigeration and No Ice Making CLRCO2175 Mode 4 Ice harvest No Refrigeration Possible CLRCO2175 Mode 5 Off Service and Repair CLRCO2175 Mode 7 Cleaning No Refrigeration Possible Error code is repeated, the thermistor is Refrigerator not cooling but ice maker working Display is showing something other than SP 38, ER or CLIce maker not operating-no water flowing over mold 2115R/2175WC/2175BEV/2275DWRR/2175DWRR Thermistor Outage Except Dwrws & 2275ZWC Review the Following Notes for General InformationThermistor Outage Dwrws & 2275ZWC Display is showing something other than SP 38 or ER Excessive Frost on evaporatorRefrigerator too warm Service and Repair CO2175F/2175RF/CO2175DWR Line Frost Free Refrigeration SystemThermistors Reed SwitchDefrost Harvest cycle Storage modeFreeze cycle Water fill cycleCO2175F Harvest-1 Cycle First 30 Seconds CO2175F Water Fill Cycle CO2175F Freeze Cycle CO2175/2275DWR Harvest-2 Cycle After 30 Seconds CO2175/2275DWR Water Fill Cycle Not making ice This can be caused by poor incoming water quality Service and Repair 1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Error Code It is most likely a refrigeration system issueON/OFF Operating ENVIRONMENTAL/ Climate Control RequirementsÉchelon Electronic Control Cabinet LightAdjusting the SET-POINT 2275ZWC/2275ZWCOL only Adjusting the SET-POINT 2275DWRWS only2275ZWCOL Showroom Mode Viewing Actual Temperature 2275DWRWS onlyViewing Actual Temperature 2275ZWC/2275ZWCOL only Service ModeForced Defrost ICE Thickness AdjustTemporary SHUTDOWN/OFFICE Mode Relay StatusError Codes E2 Thermistor 1 is shorted. Not available on CLR2160 Model Thermistor Door Switch Échelon Service Quick Reference Card Échelon Electronic Control Quick Reference Guide Viewing Actual Temperature Origins Electronic ControlOrigins Service Menu Origins Model SelectionOrigins Electronic Control Quick Reference Guide Defrost Information ALL Models Refrigeration System Diagnosis GuideSpecifications COMPRESSOR/COIL SpecificationsCLRCO2175 Refrigerator Coil OHMS-2175DWRWS/2275ZWC 2115R/2175WC/2115WC/2175BEV 2175WRR/2175DWRWSICE Maker Limit Switch CO2175F/2175RF/CO2175DWR1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Adjustments and Repair Échelon Full OverlayAdjusting Door Alignment Notch must face center of doorDoor Alignment Origins Models Checking Door AlignmentChecking Drawer Alignment Adjusting Drawer AlignmentDrawer Removal SIDE-TO-SIDE Adjustment Minor AdjustmentSevere Adjustment FRONT-TO-BACK AdjustmentTOP-TO-BOTTOM and LEFT-TO-RIGHT Adjustment RE-INSTALLATION of Drawer Ice Cube Thickness Adjustment Interval AS RequiredAccessing Evaporator or Drain CO2175F/2175RF Replacing Evaporator FAN Motor CO2175F/2175RFTo access evaporator or drain Replacing Evaporator FAN Motor CO2175DWRReplacing ICE Maker Replacing Mold and Heater CO2175F/CO2175DWR Drain Connection FACTORY-INSTALLED Drain PumpGravity Drain Remove 12 screws and back panel Materials Required LOCALLY-INSTALLED Drain PumpTools Required CLR Drain KIT Available for PurchaseULINS0168A Loose. For the disposal or Water Supply Connection WaterhookupANTI-TIP KIT CLR2160 1 Description CLR2160 2 41993 CLRCO2175 1 Screw, handle included with handle assembly CLRCO2175 2 Compression nut included with water line CLRCO2175 3 Armaflex, 1-5/8 ID included with 2276-CLRCO-S CLRCO2175 4 BF4CO5-S 2175R 1 Screw, handle included with handle assembly 2175R 2 Not 2950-01 Wire connector, 12-pin 2115R 1 Screw, handle included with handle assembly 2115R 2 41993 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL /2175WCOL22 Black Stainless Steel 2115WC/2115WCOL/2115WCOL2 1OF2 2115WC/2115WCOL/2115WCOL2 1 2115WC/2115WCOL/2115WCOL2 2 41993 2175BEV/2175BEVOL/2175BEVOL2 1 Overlay Door Stainless Steel 2175BEV/2175BEVOL/2175BEVOL2 2 Black Stainless Steel 2175DWRR/2275DWRR 1 2175DWR-TOP-BLK 2175DWRR/2275DWRR 2 Not 14159-05 Commerical handle SS accesory only 2275DWRWS/2275DWRWOL 1 Not 80-50002-00 Overlay Bracket Assembly 2275DWRWS/2275DWRWOL 2 Item Part No. Description CO2175F 1 Description CO2175F 2 0f CO2175F 2 CO2175F 3 Not 35014 Tape, drain pan heater CO2175F 4 Mold and Heater Assembly 2175RF 1 Black White Stainless Steel 2175RF 2 Solenoid only included with 73002-FFS 2175RF 3 Evaporator Assembly includes heat exchanger CO2175DWR/CO2275DWR 1 Process tube included with 73002-FFS CO2175DWR/CO2275DWR 2 Drawer Front Assembly, top CO2175DWR/CO2275DWR 3 Evaporator Assembly includes heat exchanger CO2275DWR 4 Mold and Heater Assembly 2275ZWC/2275ZWCOL 1 Overlay Stainless Steel 2275ZWC/2275ZWCOL 2 Process tube included with compressor 2275ZWC/2275ZWCOL 3 26100 Display housing 41992 1175R 1 Towel Bar Handle Assembly SS accessory only 1175R 2 Thermistor, quick connect white 1115R 1 Black Stainless Steel 1115R 2 31213 Spacer 1175WC 1 26147 Door Spacer, for Field Reversable Doors 1175WC 2 26058 1115WC 1 Pivot screw, bottom included with hinge assembly 1115WC 2 26059 1175BEV 1 26147 Door Spacer, for Field Reversable Doors 1175BEV 2 26058 ADA24R 1 0F ADA24R 1 0F DescriptionADA24R 2 0F Description Black Stainless Steel This page intentionally left blank CLRCO2175 2115R, 2115WC, 2175R, 2175WC, 2175BEV 2175RF CO2175F ADA24R This page intentionally left blank Product Information About U-LINE