U-Line 2115WCOL, 2275DWRWS, 2175WCOL, 2275DWRWOL Origins Electronic Control Quick Reference Guide

Page 55

Section 3 - Service and Repair

Error Codes

E1 Thermistor 1 is open.

E2 Thermistor 1 is shorted.

E3 Main door or bottom drawer is open longer than 20 minutes.

E4 Compressor had 100% runtime between two defrost cycles. E5 Thermistor 1 out of range + 10°F for more than 12 hours. E6 Thermistor 1 out of range -10°F for more than 12 hours.

All errors show up on display alternating between SP and the actual code.

Origins Electronic Control Quick Reference Guide

 

Task

 

 

Touch

 

 

 

 

 

 

 

 

Touch

 

 

 

 

Display

Comment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjust Setpoint

 

 

or

 

 

 

 

 

 

 

 

or

 

 

 

 

 

Touch once to get into set mode, then touch to

 

 

WARMER

 

COOLER

 

 

 

WARMER

 

COOLER

 

 

 

 

 

 

 

 

 

 

 

 

 

adjust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

View Actual Temp

 

 

Hold 5 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

WC will scroll Top/Mid/Bot temperatures.

 

 

WARMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Change F/C

 

 

Hold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

COOLER

 

 

COOLER

 

 

COOLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Service Mode

 

 

Hold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Times out after 5 minutes. Use warmer or colder

 

WARMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to scroll, light button to view.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Show Room Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Degree symbol flashes at first, then display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

COOLER

Hold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

snakes all LEDS after one minute of inactivity.

Toggle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Same key combination to remove.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display control LEDS while door is closed.

4

Display Toggle

 

WARMER

 

 

 

 

 

 

ON/

 

 

ON/

 

 

ON/

 

 

 

 

 

 

 

 

 

OFF

 

 

OFF

 

 

OFF

 

 

(Glass Door Models Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Blackout Mode

 

 

Hold 10 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

Stays off 36 hours or use light button to restore

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lights and display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hold while

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Change Model

 

ON/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

plugging in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Turn ON/OFF

 

ON/

Hold 10 seconds

 

 

 

 

 

 

 

 

 

 

 

 

o or

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Cabinet Light

 

 

Touch & Release

 

 

 

 

 

 

 

 

 

 

 

 

 

Light normally goes on/off with door opening.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressing light button will turn interior light on for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 hours then it will turn off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service Mode Listing

01Light all LED segments

02Thermistor Status

03Error Log

04Defrost Info (# in past 24 hours)

05Comp on time since last cycle

06Defrost Length

07Light Switch Status (0-toggle w/door 1-on always)

08Display Status (0-toggle w/door 1-on always)

09Restore Defaults (includes logs)

10Adjust Offset

11Data Download

12Clear Error Log

13Clear Download Memory

14Display Model Number

15Adjust Differential (use light & on/off key)

16Display Software version

99Exit Service Mode

Origins Model Selection:

1. Make sure unit is not plugged in.

2. Hold down on/off key and plug in unit.

3. Release on/off key.

4. Press and release light key.

5. Use warmer/colder to select the model number desired.

a. 49-1175R 120V b. 50-1175WC 120V c. 51-1175BEV 120V d. 52-1175R 220V e. 53-1175WC 220V f. 54-1175BEV 220V g. 56-1115R 120V h. 57-1115R 220V i. 77-1115WC 120V j. 78-1115WC 220V

6. Press and release light key.

7. Wait for flashing to stop.

8. Unplug unit-wait 5 seconds.

9.Plug unit back in.

Error Codes

E1 - Thermistor open

E2 - Thermistor shorted

E3 - Door open longer than 20 minutes

E4 - # of defrost intervals with 100% run

E5 - Actual temp 10 degrees over setpoint for more than 6 hours

E6 - Actual temp 10 degrees under setpoint for more than 6 hours

3-40

Image 55 Contents
2010 Origins Models 1115R Potential Problems with HFC-134AIntroduction Échelon Models 2115RTable of Contents Wiring Diagrams Safety Alert Definitions Safety PrecautionsLine Corporation Limited Warranty Leaders In Quality Undercounter Refrigeration Product Liability PolicySerial Number Format Warranty Claims ProcedureProof of Purchase How to Order Replacement Parts Parts ListingCustomer Call Guide CLR2160 Model Only Type 1 Black Refrigeration System Diagnosis GuideType 2 White Troubleshooting Troubleshooting Troubleshooting General Error CodesService OperationCLR2160 Ice not sized to customer satisfaction No iceToo much ice Too little iceCLRCO2175 CLRCO2175 Mode 1 Ice Making and Refrigeration ULIN0329A CLRCO2175 Mode 3 Refrigeration and No Ice Making CLRCO2175 Mode 4 Ice harvest No Refrigeration Possible CLRCO2175 Mode 5 Off Service and Repair CLRCO2175 Mode 7 Cleaning No Refrigeration Possible Error code is repeated, the thermistor is Refrigerator not cooling but ice maker working Display is showing something other than SP 38, ER or CLIce maker not operating-no water flowing over mold 2115R/2175WC/2175BEV/2275DWRR/2175DWRR Thermistor Outage Except Dwrws & 2275ZWC Review the Following Notes for General InformationThermistor Outage Dwrws & 2275ZWC Display is showing something other than SP 38 or ER Excessive Frost on evaporatorRefrigerator too warm Line Frost Free Refrigeration System Service and Repair CO2175F/2175RF/CO2175DWRThermistors Reed SwitchDefrost Water fill cycle Storage modeFreeze cycle Harvest cycleCO2175F Harvest-1 Cycle First 30 Seconds CO2175F Water Fill Cycle CO2175F Freeze Cycle CO2175/2275DWR Harvest-2 Cycle After 30 Seconds CO2175/2275DWR Water Fill Cycle Not making ice This can be caused by poor incoming water quality Service and Repair 1175R/1115R 1175WC/1115WC 1175BEV/ADA24R It is most likely a refrigeration system issue Error CodeCabinet Light Operating ENVIRONMENTAL/ Climate Control RequirementsÉchelon Electronic Control ON/OFFAdjusting the SET-POINT 2275ZWC/2275ZWCOL only Adjusting the SET-POINT 2275DWRWS only2275ZWCOL Service Mode Viewing Actual Temperature 2275DWRWS onlyViewing Actual Temperature 2275ZWC/2275ZWCOL only Showroom ModeRelay Status ICE Thickness AdjustTemporary SHUTDOWN/OFFICE Mode Forced DefrostError Codes E2 Thermistor 1 is shorted. Not available on CLR2160 Model Thermistor Door Switch Échelon Service Quick Reference Card Échelon Electronic Control Quick Reference Guide Origins Electronic Control Viewing Actual TemperatureOrigins Model Selection Origins Service MenuOrigins Electronic Control Quick Reference Guide Refrigeration System Diagnosis Guide Defrost Information ALL ModelsCOMPRESSOR/COIL Specifications SpecificationsCLRCO2175 2115R/2175WC/2115WC/2175BEV 2175WRR/2175DWRWS Refrigerator Coil OHMS-2175DWRWS/2275ZWCCO2175F/2175RF/CO2175DWR ICE Maker Limit Switch1175R/1115R 1175WC/1115WC 1175BEV/ADA24R Échelon Full Overlay Adjustments and RepairNotch must face center of door Adjusting Door AlignmentChecking Door Alignment Door Alignment Origins ModelsChecking Drawer Alignment Adjusting Drawer AlignmentDrawer Removal FRONT-TO-BACK Adjustment Minor AdjustmentSevere Adjustment SIDE-TO-SIDE AdjustmentTOP-TO-BOTTOM and LEFT-TO-RIGHT Adjustment RE-INSTALLATION of Drawer Interval AS Required Ice Cube Thickness AdjustmentReplacing Evaporator FAN Motor CO2175F/2175RF Accessing Evaporator or Drain CO2175F/2175RFReplacing Evaporator FAN Motor CO2175DWR To access evaporator or drainReplacing ICE Maker Replacing Mold and Heater CO2175F/CO2175DWR Drain Connection FACTORY-INSTALLED Drain PumpGravity Drain Remove 12 screws and back panel CLR Drain KIT Available for Purchase LOCALLY-INSTALLED Drain PumpTools Required Materials RequiredULINS0168A Loose. For the disposal or Waterhookup Water Supply ConnectionANTI-TIP KIT CLR2160 1 Description CLR2160 2 41993 CLRCO2175 1 Screw, handle included with handle assembly CLRCO2175 2 Compression nut included with water line CLRCO2175 3 Armaflex, 1-5/8 ID included with 2276-CLRCO-S CLRCO2175 4 BF4CO5-S 2175R 1 Screw, handle included with handle assembly 2175R 2 Not 2950-01 Wire connector, 12-pin 2115R 1 Screw, handle included with handle assembly 2115R 2 41993 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL/2175WCOL2 1 2175WC/2175WCOL /2175WCOL22 Black Stainless Steel 2115WC/2115WCOL/2115WCOL2 1OF2 2115WC/2115WCOL/2115WCOL2 1 2115WC/2115WCOL/2115WCOL2 2 41993 2175BEV/2175BEVOL/2175BEVOL2 1 Overlay Door Stainless Steel 2175BEV/2175BEVOL/2175BEVOL2 2 Black Stainless Steel 2175DWRR/2275DWRR 1 2175DWR-TOP-BLK 2175DWRR/2275DWRR 2 Not 14159-05 Commerical handle SS accesory only 2275DWRWS/2275DWRWOL 1 Not 80-50002-00 Overlay Bracket Assembly 2275DWRWS/2275DWRWOL 2 Item Part No. Description CO2175F 1 Description CO2175F 2 0f CO2175F 2 CO2175F 3 Not 35014 Tape, drain pan heater CO2175F 4 Mold and Heater Assembly 2175RF 1 Black White Stainless Steel 2175RF 2 Solenoid only included with 73002-FFS 2175RF 3 Evaporator Assembly includes heat exchanger CO2175DWR/CO2275DWR 1 Process tube included with 73002-FFS CO2175DWR/CO2275DWR 2 Drawer Front Assembly, top CO2175DWR/CO2275DWR 3 Evaporator Assembly includes heat exchanger CO2275DWR 4 Mold and Heater Assembly 2275ZWC/2275ZWCOL 1 Overlay Stainless Steel 2275ZWC/2275ZWCOL 2 Process tube included with compressor 2275ZWC/2275ZWCOL 3 26100 Display housing 41992 1175R 1 Towel Bar Handle Assembly SS accessory only 1175R 2 Thermistor, quick connect white 1115R 1 Black Stainless Steel 1115R 2 31213 Spacer 1175WC 1 26147 Door Spacer, for Field Reversable Doors 1175WC 2 26058 1115WC 1 Pivot screw, bottom included with hinge assembly 1115WC 2 26059 1175BEV 1 26147 Door Spacer, for Field Reversable Doors 1175BEV 2 26058 ADA24R 1 0F Description ADA24R 1 0FADA24R 2 0F Description Black Stainless Steel This page intentionally left blank CLRCO2175 2115R, 2115WC, 2175R, 2175WC, 2175BEV 2175RF CO2175F ADA24R This page intentionally left blank About U-LINE Product Information