Traulsen RBC400RT, RBC200RT owner manual By Time Type Chill ↓CYCLE Time, Holding, Stop/Reset

Page 14

VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE

MAIN MENU

AIR 35°F

BY

TEMP

BY PROD

BY

TIME

 

08:05:01

MORE

Main Menu Display

VII. b - STARTING A CHILL CYCLE - BY TIME:

Use of the chilling mode BY TIME means that product will be constantly chilled until the set chill time, as determined by the operator, has elapsed, at which time the cycle is complete and operation reverts to normal refrigerated holding mode.

MAIN MENU

AIR 35°F

 

BY TEMP

BY PROD

 

 

 

 

 

BY TIME

 

08:05:01

MORE

BY TIME

 

 

 

 

 

TYPE: CHILL

 

CYCLE TIME:

01:30

 

MAIN

START

BY TIME

TYPE: CHILL

CYCLE TIME: 01:30

MAIN START

NOTE: If desired you may insert the food probes into the food product as shown in section VI. a., however please be aware that these will only display the product temperatures and have no effect on the chilling process in this mode.

BY TIME

 

 

TYPE: CHILL

 

 

CYCLE TIME:

01:30

MAIN

 

 

START

BY TIME

 

 

TYPE: CHILL

 

 

CYCLE TIME:

01:30

 

 

START

MAIN

The main menu should be displayed on the control. To begin a chill cycle BY TIME follow the below instructions:

STEP ONE: Press the button to the left of where BY TIME is shown on the display. The menu will then change to show TYPE : CHILL.

STEP TWO: Select the TYPE by pressing the button to the left of where by TYPE is shown on the display. The display will toggle between CHILL (blast chill mode), SOFT (soft chill mode) and FREEZE (flash chill mode) each time you press this button.

STEP THREE: Adjust the CYCLE TIME (not required) if you wish to deviate from the factory preset times (see chart below). This is done by pressing the buttons to the left and right of the UP and DOWN arrows.

MODELS

BY TEMP

INITIAL TIME

TIME RANGE

SETTING

 

 

 

 

All Models

Blast Chill

01:30

00:01 To 09:00

 

 

 

 

All Models

Soft Chill

01:30

00:01 To 09:00

 

 

 

 

All Models

Freeze

01:30

00:01 To 09:00

STEP FOUR: Close the door. You are now ready to begin chilling. If you are satisfied with the selections made in steps 1 thru 3, press the button to the right of where START is shown on the display. The chill time remaining will display in the lower left corner of the display: Hr: Min: Sec: (hours:minutes:seconds).

NOTE: Prior to selecting START you can return to the MAIN MENU at any time by pushing the button to the left of where MAIN is shown on the display.

When a programmed batch has reached completion (i.e. the timer has counted down to 0:00:00) the alarm will activate, providing an audible notification (buzzer). This can be turned OFF by pressing the button to the right of where MUTE is shown on the display.

HOLDING

AIR: 14°F

1

41°F

43°F 3

2

44°F

 

 

1:16:01

 

 

MUTE

HOLDING

AIR 35°F

1

159°F

156°F 3

2

154°F

 

 

1:30:00

STOP/RESET

BY

TIME

 

 

 

ADD 30 MINUTES

 

RESET TIMER

STOP

CONTINUE

NOTE: After completion of a batch the unit will return to normal refrigerated holding temperatures (37°F). Product which was either BLAST or SOFT chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was completed product must be removed immediately upon batch completion.

OTHER BY TIME CONTROL FUNCTIONS

During a chill cycle BY TIME, the control has several preset functions that can be accessed by pressing the button to the left of where STOP/RESET is shown on the display.

ADD 30 MINUTES: adds 30 additional minutes to the timer.

RESET TIMER: re-starts the timer at the original time setting.

CONTINUE: resumes the cycle at the time remaining.

STOP: control returns to the MAIN MENU.

-13-

Image 14
Contents Important Warranty Notes Table of Contents IntroductionStart By TimeType Chill Blast Chiller Quick Start Checklist Main MenuBasic Operating Guidelines III. Installation II. Receipt InspectionIII. Installation Front IV. Care & Maintenance Other Reading the Serial TAGVI. the Smartchill Control VersionMain By Temp↓TARGET Temp 0F↑ MuteChilling AIR Holding AIRADD/REMOVE ContinueBy Time Type Chill ↓CYCLE Time STOP/RESETTime ADD 30 Minutes Reset Timer Stop Continue Holding↑CHICKEN Parts ↓SOUP Vegetable By Prod↓TIM Smith Chicken PartsBy Product Defrost VII. Operating the Blast Chill Control Hold Mode & DefrostMore VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products Users VII. Operating the Blast Chill Control SET UP Users↓TIM Smith ↑ ↓PASSWORD PIN 07↑ ADDSYS PAR VII. Operating the Blast Chill Control SysparProducts Cancel Enter SYS PAR SET Clock Itemyear ItemmonthVIII. Smartchilltm Communications Communicating with Computer Please WaitIX. Glossary Replacement Parts List XI. Summary of Error Messages XI. a Food Probe Error During Chill Cycle by TempXII. Warranty Information Standard Domestic WarrantyXIII. Mechanical Trouble Shooting Guide Hours of Operation