VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE

MAIN MENU

AIR 35°F

BY

TEMP

BY PROD

BY

TIME

 

08:05:01

MORE

Main Menu Display

VII. a - STARTING A CHILL CYCLE - BY TEMP:

Use of the chilling mode BY TEMPERATURE means that product will be constantly chilled until the food probe(s) temperature reaches the preset target temperature, at which time the cycle is complete and operation reverts to normal refrigerated holding mode.

MAIN MENU

AIR

35°F

 

 

 

BY PROD

 

BY TEMP

 

BY TIME

 

 

08:05:01

MORE

BY TEMPERATURE

 

 

 

 

 

 

 

TYPE: CHILL

 

 

TARGET TEMP:

37°F

 

MAIN

START

BY TEMPERATURE

TYPE: CHILL

TARGET TEMP: 0°F

MAIN START

The main menu should be displayed on the control. To begin a chill cycle BY TEMPERATURE follow the below instructions:

STEP ONE: Press the button to the left of where BY TEMPERATURE is shown on the display. The menu will then change to show TYPE : CHILL.

STEP TWO: Select the TYPE by pressing the button to the left of where by TYPE is shown on the display. The display will change between CHILL (blast chill mode), SOFT (soft chill mode) and FREEZE (freeze chill mode).

STEP THREE: Adjust the TARGET TEMPERATURE if you wish to deviate from the factory preset temperatures (see chart below). This is done by pressing the buttons to the left and right of the UP and DOWN arrows.

MODELS

BY TEMP

FACTORY PRESET

RANGE

TARGET RANGE

 

 

 

 

All Models

Blast Chill

37°F

33-40°F

 

 

 

 

All Models

Soft Chill*

37°F

33-40°F

 

 

 

 

All Models

Freeze*

0°F

-22-28°F

 

 

 

 

*Soft Chill and Freeze modes are not available on GC units.

STEP FOUR: Insert the food probes into the food product as shown in section VI. a.

NOTE: The SmartProbes sense the product temperature and are automatically selected (if product temperature is 75°F or higher). If probes are not sensed, probes have to be enabled using the SELECT PROBE menu.

BY TEMPERATURE

TYPE: CHILL

 

 

 

TARGET TEMP:

 

37°F

MAIN

 

 

 

 

START

BY TEMPERATURE

TYPE: CHILL

 

 

 

TARGET TEMP:

 

37°F

 

 

 

START

MAIN

 

CHILLING

AIR: 14°F

1

41°F

 

DONE 3

2

44°F

 

 

 

 

1:16:01

 

 

 

 

 

MUTE

STEP FIVE: Close the door. You are now ready to begin chilling. If you are satisfied with the selections made in steps 1 thru 3, press the button to the right of where START is shown on the display. The chill time will display in the lower left corner of the display: Hr: Min: Sec: (hours:minutes:seconds).

NOTE: You can return to the MAIN MENU at any time by pushing the button to the left of where MAIN is shown on the display.

When a programmed batch has reached completion the alarm will activate, providing an audible notification (buzzer). This can be turned OFF by pressing the button to the right of where MUTE is shown on the display.

(This step is repeated as each probe reaches the target temperatures; see page 14).

NOTE: After completion of all batches the unit will return to normal refrigerated holding temperatures (37°F). Product which was either BLAST or SOFT chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was completed product must be removed immediately upon batch completion.

-11-

Image 12
Contents Important Warranty Notes Table of Contents IntroductionBy Time Type ChillStart Blast Chiller Quick Start Checklist Main MenuBasic Operating Guidelines III. Installation II. Receipt InspectionIII. Installation Front IV. Care & Maintenance Other Reading the Serial TAGVI. the Smartchill Control VersionBy Temp ↓TARGET Temp 0F↑Main MuteHolding AIR ADD/REMOVEChilling AIR ContinueSTOP/RESET Time ADD 30 Minutes Reset Timer Stop ContinueBy Time Type Chill ↓CYCLE Time HoldingBy Prod ↓TIM Smith↑CHICKEN Parts ↓SOUP Vegetable Chicken PartsBy Product VII. Operating the Blast Chill Control Hold Mode & Defrost MoreDefrost VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products VII. Operating the Blast Chill Control SET UP Users ↓TIM Smith ↑ ↓PASSWORD PIN 07↑Users ADDVII. Operating the Blast Chill Control Syspar ProductsSYS PAR Cancel Enter SYS PAR SET Clock Itemyear ItemmonthVIII. Smartchilltm Communications Communicating with Computer Please WaitIX. Glossary Replacement Parts List XI. Summary of Error Messages XI. a Food Probe Error During Chill Cycle by TempXII. Warranty Information Standard Domestic WarrantyXIII. Mechanical Trouble Shooting Guide Hours of Operation