Traulsen RBC200RT, RBC400RT By Prod, ↓TIM Smith, ↑CHICKEN Parts ↓SOUP Vegetable, Chicken Parts

Page 15

VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE

VII. c - STARTING A CHILL CYCLE - BY PRODUCT:

Use of the chilling mode BY PRODUCT allows the operator to select from a listing of chill parameters for various previously programmed products. These products will then be chilled either BY TEMPERATURE or BY TIME, depending upon their individual settings. When the chill cycle is completed operation reverts to normal refrigerated holding mode.

The main menu should be displayed on the control. To begin a chill cycle BY PRODUCT follow the below instructions:

STEP ONE: Insert the food probes into the food product as shown in section VI. a and close the door.

STEP TWO: Press the button to the right of where BY PRODUCT is shown on the display. The menu will then change to show TYPE:

CHILL.

STEP THREE: Select the USER (if more than one user has been previously entered) by pressing the buttons to the left and right of the UP and DOWN arrows.

STEP FOUR: Select the PRODUCT to be chilled. The display will show the two most recently chilled products. You can scroll through the listing of products by pressing the buttons to the left of the UP and DOWN arrows. See page 16 for more information.

STEP FIVE: Once the product you wish to chill is shown on the display, press the button to the right of where this is shown to recall that products chill paramaters and begin chilling.

If the product selected is being chilled BY TEMPERATURE, the chill cycle time will be shown in the lower left corner of the display: Hr: Min: Sec: (hours:minutes:seconds).

If the product selected is being chilled BY TIME, the time remaining will be shown in the lower left corner of the display: Hr: Min: Sec: (hours:minutes:seconds).

NOTE: You can return to the MAIN MENU at any time by pushing the button to the left of where MAIN is shown on the display.

When a programmed batch has reached completion the alarm will activate, providing an audible notification (buzzer). This can be turned OFF by pressing the button to the right of where MUTE is shown on the display.

(This step is repeated as each probe reaches the target temperatures; see page 14).

NOTE: After completion of all batches the unit will return to normal refrigerated holding temperatures (37°F). Product which was either BLAST or SOFT chilled may remain in the blast chiller. However, if a FREEZE CHILL cycle was completed product must be removed immediately upon batch completion.

Refer to page 14 or 19 for printing procedures and information.

MAIN

MENU

AIR 35°F

BY TEMP

BY PROD

BY

TIME

 

08:05:01

MORE

 

Main Menu Display

MAIN

MENU

AIR 35°F

BY TEMP

BY PROD

BY

TIME

 

08:05:01

MORE

BY PRODUCT

 

 

 

 

 

 

TYPE: CHILL

 

TARGET TEMP:

37°F

 

MAIN

START

SELECT USER:

 

 

 

 

 

TIM SMITH

 

BACK

SELECT

SELECT PRODUCT:

CHICKEN PARTS SOUP VEGETABLE

MAIN MENU

SELECT PRODUCT:

CHICKEN PARTS

SOUP VEGETABLE

MAIN MENU

NOTE: If the product you wish to se- lect is on the Product List shown on page 20 but is not available from the SELECT PRODUCT menu of the con- trol display, it first needs to be enabled. The Supervisor should refer to Set-Up Products on page 23.

-14-

Image 15
Contents Important Warranty Notes Introduction Table of ContentsBy Time Type ChillStart Main Menu Blast Chiller Quick Start ChecklistBasic Operating Guidelines II. Receipt Inspection III. InstallationIII. Installation Front IV. Care & Maintenance Reading the Serial TAG OtherVersion VI. the Smartchill Control Mute By Temp ↓TARGET Temp 0F↑ MainContinue Holding AIRADD/REMOVE Chilling AIRHolding STOP/RESETTime ADD 30 Minutes Reset Timer Stop Continue By Time Type Chill ↓CYCLE TimeChicken Parts By Prod↓TIM Smith ↑CHICKEN Parts ↓SOUP VegetableBy Product VII. Operating the Blast Chill Control Hold Mode & Defrost MoreDefrost VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products ADD VII. Operating the Blast Chill Control SET UP Users↓TIM Smith ↑ ↓PASSWORD PIN 07↑ UsersVII. Operating the Blast Chill Control Syspar ProductsSYS PAR Itemmonth Cancel Enter SYS PAR SET Clock ItemyearCommunicating with Computer Please Wait VIII. Smartchilltm CommunicationsIX. Glossary Replacement Parts List XI. a Food Probe Error During Chill Cycle by Temp XI. Summary of Error MessagesStandard Domestic Warranty XII. Warranty InformationHours of Operation XIII. Mechanical Trouble Shooting Guide