Traulsen RBC400RT, RBC200RT owner manual Itemmonth, Cancel Enter SYS PAR SET Clock Itemyear

Page 22

VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR

VII. j - SYSPAR - SETTING THE VARIOUS CONTROL FEATURES:

By accessing SYSPAR (system parameters), the operator can adjust many control features to better suit their operational needs, such as: Clock Settings, Probes, Temperature Scale (F or C), Alarm Settings and Chill Parameters. It also provides for an easy return to the original factory default settings with a RESET feature.

From the SETUP screen, select SYS PAR to get:

Press to select SYS PAR.

SYS PAR: SET CLOCK

Press to select SYS PAR.

Press to decrease ITEM.

Press to increase ITEM.

ITEM:MONTH

 

Press to decrease VALUE.

VALUE:APRIL

 

Press to increase VALUE.

Press to return to MAIN MENU*

CANCEL

ENTER

Press to return to SETUP with saving.

 

 

*without saving.

SYS PAR Menu Display

1)SET CLOCK

a)MONTH (JANUARY – DECEMBER)

b)DATE (1 – 311 )

c)YEAR (2003 – 2079)

d)DAY OF WEEK (SUNDAY – SATURDAY)

e)HOUR (0 – 23)

f)MINUTE (0 – 59)

g)DLS TIME (ENABLED – DISABLED)

2)PROBES

a)

1 (ON – OFF) b)

2 (ON – OFF)

c)3 (ON – OFF)

3) DISPLAY

a)TEMPERATURES (IN DEG C – IN DEG F)

4) LOGGING

a)TIME (5-MINUTES30-MINUTES)

5) ALARM

a)CYCLE RUNNING (NO – yes)

b)CYCLE ENDS (NO – yes)

c)PRINTER ERROR (NO – yes)

d)HIGH/LOW TEMP (no – YES)

e)POWER FAILURE (no – YES)

6)REMINDERS

a)DOOR OPEN (0 – 2 MINUTES)

7)BLAST

a)

TARGET (33 – 40)

b)

AIR (10 – 40)

c)

HOLD (10 – 40)

d)

HIGH ALARM (35 – 60)

e)LOW ALARM (-30 – 34)

8)SOFT CHILL

a)

BY TEMP (5 – 20)

b)

BY TIME (10 – 90)

c)2ND TEMP (10 – 40)

9)FREEZE CHILL

a)

TARGET (-22 – 28)

b)

AIR (-32 – 20)

c)

HOLD (10 – 40)

d)

HIGH ALARM (20 – 45)

e)LOW ALARM (-30 – 0)

10) RESET

a)PARAMETERS (YES – NO)

SYS PAR:

SET CLOCK

ITEM:MONTH

VALUE:APRIL

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:DATE

 

VALUE:04/XX/00

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:YEAR

 

VALUE:04/14/XX

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:HOUR

 

VALUE:XX:00

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:MINUTE

VALUE:10:XX

CANCEL

ENTER

1Last day is corrected for month and leap year.

-21-

Image 22
Contents Important Warranty Notes Table of Contents IntroductionType Chill By TimeStart Blast Chiller Quick Start Checklist Main MenuBasic Operating Guidelines III. Installation II. Receipt InspectionIII. Installation Front IV. Care & Maintenance Other Reading the Serial TAGVI. the Smartchill Control VersionMain By Temp↓TARGET Temp 0F↑ MuteChilling AIR Holding AIRADD/REMOVE ContinueBy Time Type Chill ↓CYCLE Time STOP/RESETTime ADD 30 Minutes Reset Timer Stop Continue Holding↑CHICKEN Parts ↓SOUP Vegetable By Prod↓TIM Smith Chicken PartsBy Product More VII. Operating the Blast Chill Control Hold Mode & DefrostDefrost VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products Users VII. Operating the Blast Chill Control SET UP Users↓TIM Smith ↑ ↓PASSWORD PIN 07↑ ADDProducts VII. Operating the Blast Chill Control SysparSYS PAR Cancel Enter SYS PAR SET Clock Itemyear ItemmonthVIII. Smartchilltm Communications Communicating with Computer Please WaitIX. Glossary Replacement Parts List XI. Summary of Error Messages XI. a Food Probe Error During Chill Cycle by TempXII. Warranty Information Standard Domestic WarrantyXIII. Mechanical Trouble Shooting Guide Hours of Operation