Traulsen RBC400RT, RBC200 VII. Operating the Blast Chill Control SET UP Users, Add, Enter

Page 20

VII. OPERATING THE BLAST CHILL CONTROL - SET UP USERS

MAIN MENU

AIR 35°F

VII. h - SET-UP USERS:

The SmartChill® control offers the convenience of having individual operators

BY TEMP

BY PROD

have their own unique BY PRODUCT and SYSPAR settings already

BY TIME

 

 

programmed, facilitating the changing chilling needs of different production

08:05:01

 

 

shifts. To add new user settings please follow the below procedure.

 

 

MAIN MENU

AIR 35°F

BY TEMP

BY PROD

BY TIME

 

 

08:05:01

 

MORE

MAIN MENU

08:06:01

HOLD PROD

PRINT

DEFROST

SETUP

BACK

 

 

SETUP

09:04:11

PRODUCTS

SYS PAR

USERS

 

MAIN MENU

SETUP USERS:

ADD

DELETE ALL

EDIT/DELETE

B A C K

SELECT SUPERVISOR:

TIM SMITH PASSWORD (PIN): 07

CANCEL ENTER

ENTER NAME:

_

BACK

NEXT

CANCEL

ENTER

ENTER NAME:

 

TIM SMITH

BACK

NEXT

CANCEL

ENTER

SETUP USER: SECURITY LEVEL:0PERPASSWORD (PIN): 00

ENTER

SETUP USER: SECURITY LEVEL:0PERPASSWORD (PIN): 23

ENTER

SETUP USER: SECURITY LEVEL:0PERPASSWORD (PIN): 23

ENTER

STEP ONE: From the MAIN MENU, select MORE by pressing the button to the right of where this is shown on the display. The menu shown will then change to display additional menu options.

STEP TWO: Press the button to the right of where SETUP is shown on the display. Note when you first enter SETUP, only Preset Supervisor is available. On the PASSWORD (PIN) line, use the UP or DOWN keys until 57 is displayed as the Preset Supervisors Personal Identification Number. Press ENTER. The menu shown will then change back to display the SETUP menu options.

If users have already been setup, select the supervisors name using the UP or DOWN keys. On the next line, use the UP or DOWN keys to enter their Password (or Personal Identification Number). Press ENTER. The menu shown will then change back to display the SETUP menu options.

STEP THREE: Press the button to the left of where USERS is shown on the display.

STEP FOUR:

Press the button to the left of where ADD is shown on the

 

display to add new users to the roster.

 

NOTE: The first user entered is automatically given Supervisor

 

access. This can be changed by using the EDIT/DELETE

 

selection to change a given users security level or PIN number,

 

or delete an entire user from the roster. DELETE ALL removes

 

all users from the roster.

STEP FIVE:

To enter the name of a new user, press the buttons to the left

 

and right of the UP and DOWN arrows to scroll through the

 

alphabet, one character at a time. Press the button to the right

 

of where NEXT is shown on the display to set this character and

 

move on to the next letter, repeating this until the new users

 

name is complete.

 

NOTE: BACK moves the cursor one space to the left to allow for

 

editing. Press the button to the right of where ENTER is shown

 

on the display to save the new users name (CANCEL aborts this

 

process).

STEP SIX:

Select the new users security level by pressing the button to

 

the right of where SECURITY LEVEL is shown on the display

 

(pressing this button toggles between OPER (operator level)

 

and SUPV (supervisor). Please note that at least one user must

 

already be set-up as a supervisor before an operator access

 

level can be selected.

STEP SEVEN: To enter the new use’s two-digit PASSWORD, press the buttons to the left and right of the UP and DOWN arrows to scroll through the numbers 00-99. Press the button to the right of where ENTER is shown on the display to set this users access level and pin number. The display will return to the SET- UP USERS menu. Press the button to the right of where BACK is shown on the display to return to the SETUP menu. Press the button to the left of where MAIN is shown on the display to return to the main menu.

-19-

Image 20
Contents Important Warranty Notes Table of Contents IntroductionStart By TimeType Chill Blast Chiller Quick Start Checklist Main MenuBasic Operating Guidelines III. Installation II. Receipt InspectionIII. Installation Front IV. Care & Maintenance Other Reading the Serial TAGVI. the Smartchill Control VersionBy Temp ↓TARGET Temp 0F↑Main MuteHolding AIR ADD/REMOVEChilling AIR ContinueSTOP/RESET Time ADD 30 Minutes Reset Timer Stop ContinueBy Time Type Chill ↓CYCLE Time HoldingBy Prod ↓TIM Smith↑CHICKEN Parts ↓SOUP Vegetable Chicken PartsBy Product Defrost VII. Operating the Blast Chill Control Hold Mode & DefrostMore VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products VII. Operating the Blast Chill Control SET UP Users ↓TIM Smith ↑ ↓PASSWORD PIN 07↑Users ADDSYS PAR VII. Operating the Blast Chill Control SysparProducts Cancel Enter SYS PAR SET Clock Itemyear ItemmonthVIII. Smartchilltm Communications Communicating with Computer Please WaitIX. Glossary Replacement Parts List XI. Summary of Error Messages XI. a Food Probe Error During Chill Cycle by TempXII. Warranty Information Standard Domestic WarrantyXIII. Mechanical Trouble Shooting Guide Hours of Operation