Blast Chiller Quick Start Checklist

Starting a Chill Cycle - All Models

1)Load product into the blast chiller. Both full and partial loads are OK, but for best results evenly distribute product throughout the interior tray slides or roll-in rack.

2)Insert a food probe into the top, bottom and middle level pans. The probe should be located in the center of the food pan, at about the halfway point of the product depth.

3)Close the door.

4)Press the EZ Start button.

The Blast Chill Process - All Models

1)While in a blast chill cycle, cold air is rapidly being circulated around the food pans in order to remove heat as rapidly as possible.

2)Actual chill times will vary depending on many product related factors such as starting temperature, product density, cycle load, content, etc.

3)To insure food safety, the probes constantly monitor product core temperature(s) throughout each chill cycle, as well as during any holding period afterwards. Reports available at the end of each chill cycle can then be used by the operator to confirm that both FDA critical control points were met in accordance with the current food code.

Concluding a Chill Cycle - All Models

1)Upon each probe reaching target temperature (37°F) an audible alarm will sound for 30-seconds, and the probe number on the control display will continuously flash DONE.

2)Press the button alongside the probe flashing DONEin order to conclude that probes batch.

3)The control will now display the print menu.

3a. Press BOTH to receive both record and label printouts 3b. Press RECORD to receive only the record printout 3c. Press LABEL to receive only the label printout

3d. Press NONE if no printouts are desired.

NOTE: After printing has completed for either the RECORD, LABEL or BOTH, the control will continue to display the print menu until NONE is selected. This allows for multiple copies of each to be printed as needed.

4)Repeat for any remaining probes as they complete in turn. Pressing NONE after the final probe has completed returns the display to the

MAIN MENU.

5)Any probes used should be properly sanitized prior to use in another batch.

For more details and/or to make use of other

control features please refer to pages 12 - 23 of this manual.

-3-

Image 4
Contents Important Warranty Notes Table of Contents IntroductionType Chill By TimeStart Blast Chiller Quick Start Checklist Main MenuBasic Operating Guidelines III. Installation II. Receipt InspectionIII. Installation Front IV. Care & Maintenance Other Reading the Serial TAGVI. the Smartchill Control VersionBy Temp ↓TARGET Temp 0F↑Main MuteHolding AIR ADD/REMOVEChilling AIR ContinueSTOP/RESET Time ADD 30 Minutes Reset Timer Stop ContinueBy Time Type Chill ↓CYCLE Time HoldingBy Prod ↓TIM Smith↑CHICKEN Parts ↓SOUP Vegetable Chicken PartsBy Product More VII. Operating the Blast Chill Control Hold Mode & DefrostDefrost VII. Operating the Blast Chill Control Printing VII. Operating the Blast Chill Control SET UP Products VII. Operating the Blast Chill Control SET UP Users ↓TIM Smith ↑ ↓PASSWORD PIN 07↑Users ADDProducts VII. Operating the Blast Chill Control SysparSYS PAR Cancel Enter SYS PAR SET Clock Itemyear ItemmonthVIII. Smartchilltm Communications Communicating with Computer Please WaitIX. Glossary Replacement Parts List XI. Summary of Error Messages XI. a Food Probe Error During Chill Cycle by TempXII. Warranty Information Standard Domestic WarrantyXIII. Mechanical Trouble Shooting Guide Hours of Operation