Traulsen RBC200 & RBC400, RBC50, RBC100 owner manual VI. Blast Chill Operation cont’d

Page 9

VI. BLAST CHILL OPERATION (contd)

VI. c - GROUPING FOODS TO FORM BATCHES (contd):

 

AVG. COOLING TIME

FOOD

RELATIVE TO WATER

LASAGNA

+89%

SLOWER

 

 

CHILI

+64%

 

 

MASHED POTATOES

+64%

 

 

MEAT LOAF (WHOLE)

+61%

 

 

RICE

+61%

 

 

CREAM OF WHEAT

+60%

 

 

KERNEL CORN

+58%

 

 

SOUP (THICK TYPES)

+49%

 

 

BAKED POTATOES

+47%

 

 

CHOPPED STEAKS/GRAVY

+43%

 

 

REFRIED BEANS

+43%

 

 

SPAGHETTI/MEAT SAUCE

+39%

 

 

GREEN BEANS

+39%

 

 

SCRAMBLED EGGS

+36%

 

 

MACARONI & CHEESE

+33%

 

 

CHICKEN BREASTS

+12%

 

 

WATER

0%

 

 

FASTER

 

 

VI. d - MAXIMUM LOAD PER BATCH:

Model RBC50 has a maximum recommended capacity of 50 lbs. of food. This would be approximately five (5) 12x 20x 2-1/2pans with 2thick product.

Model RBC100 has a maximum recommended capac- ity of 100 lbs. of food. This would be approximately ten (10) 12x 20x 2-1/2pans with 2thick product.

Models RBC200 and RBC200RT have a maximum rec- ommended capacity of 200 lbs. of food. This would be approximately twenty (20) 12x 20x 2-1/2pans (one cart) with 2thick product.

Models RBC400 and RBC400RT have a maximum rec- ommended capacity of 400 lbs. of food. This would be approximately forty (40) 12x 20x 2-1/2pans (two carts) with 2thick product.

All Blast Chiller units will provide more uniform cool- ing of the food if they are setup close to their capacity of food with each blast chill cycle. This is due to the fact that the heat being removed from the food tends to moderate the temperature of the air being circulated. Lightly loaded blast chill cycles tend to run with colder air temperatures, which can cause the food to freeze near the outside surfaces of the pans. The soft chill cycle should be used if the chiller is loaded less than 50% of capacity.

VI. e - PAN PLACEMENT IN THE UNIT:

All pans of food with a batch should be grouped to- gether in the same area of the unit (i.e. Top, Middle, or

VI. e - PAN PLACEMENT IN THE UNIT (contd): Bottom). This will facilitate easier removal from the unit if more than one batch is being blast chilled at the same time, but have different completion times.

In the RBC50 model, air flows through the unit in a horizontal plane from right to left, and left to right, there- fore, there is no significant difference if the pans are placed toward the rear of the unit or toward the door.

In the RBC100 model, air flows through the unit in a horizontal plane from right to left, therefore, there is no significant difference if the pans are placed toward the rear of the unit or toward the door (see figure 14).

AIR FLOW

Fig. 14

On the Roll-In and Roll-Thru models, it is recommended that the slower cooling foods within the batch be placed in the area of the cart which will be toward the rear of the Blast Chill interior (away from the door). This area of the unit receives the incoming air from the blowers and is slightly cooler than the air passing over the pans nearest the doors (see figure 15).

 

Rear Of

Door

Interior

 

Slower

Cooling

FasterFood

Cooling

Food

BATCH

#1

BATCH

#2

-8-

Fig. 15

Image 9
Contents Traulsen & Co., Inc Serial TAG Table of ContentsII. Receipt Inspection III. InstallationIII. Installation III. e Cord & PlugIII. f Electrical Requirements RBC400 & RBC400RT Wiring connections III. l Installing RBC50 Control PanelControl BOX RBC400 Control BOX LocationIV. a Cleaning the Condenser IV. Care & MaintenanceIV. b Cleaning the Exterior Service Agency Check & START-UPRecommended Not Recommended VI. Blast Chill OperationVI. Blast Chill Operation cont’d ↑ 1 ↑ FoodSensing Area Probe VI. h Example Batches for RBC100 Door Interior VII. Operating the Blast Chill Control VII. Operating the Blast Chill Control cont’d Batch Number Enter Press T on logo to start configuration and unlock VIII. Understanding Printouts VIII. b Constant Chill Cycle Batch DataVIII. a Current Data Printout VIII. c Blast Chill Cycle Batch Data VIII. Understanding Printouts cont’dVIII. d the 72-HOUR Data LOG Food Probe Failure Warning Power Loss NotificationChill Cycle Batch Over 6 Hours Refrigeration FailureSymptom Probable CAUSE/SOLUTION IX. Trouble Shooting GuideWiring Diagram RBC50 Wiring Diagram RBC100 Wiring Diagram RBC200 & RBC200RT Wiring Diagram RBC400 & RBC400RT Standard Domestic Warranty XI. Warranty InformationXIII. Index XII. Parts ListPART/DESCRIPTION OTR-TRA-13Hours of Operation Extended Warranty Service Hours

RBC100, RBC200 & RBC400, RBC50, RBC50, RBC100, RBC200, RBC400, RBC200RT, RBC400RT specifications

The Traulsen RBC series represents a significant advancement in commercial refrigeration, offering a range of robust and reliable products suitable for various foodservice applications. The lineup includes the RBC50, RBC100, RBC200, RBC400, RBC200RT, and RBC400RT, each designed to meet specific storage and operational needs while maintaining exceptional performance and energy efficiency.

The Traulsen RBC50 is a compact refrigerator ideal for smaller kitchens, boasting an impressive refrigeration capacity while taking up minimal space. It features a stainless steel exterior and aluminum interior, ensuring both durability and ease of cleaning. This model is equipped with a self-closing door and a magnetic door gasket that ensures a snug fit, which helps to maintain consistent temperatures.

The RBC100 follows closely, offering greater capacity without compromising on quality. It features digital controls that provide accurate temperature settings and monitoring, allowing operators to maintain optimal conditions for food storage. With energy-efficient insulation and a high-performance compressor, the RBC100 is designed for rigorous use in busy commercial environments.

Moving up in capacity and functionality, the RBC200 and RBC400 models cater to larger foodservice operations. The RBC200 provides extensive storage space with energy-efficient components, including a forced-air cooling system that ensures even temperature distribution throughout the cabinet. The RBC400, with its impressive size, is perfect for high-volume establishments, featuring multiple shelves and an optimized layout for easy access to stored goods.

For operations requiring rapid cooling, the RBC200RT and RBC400RT models add advanced refrigeration technologies. The RT series employs rapid chill functionality, ideal for quickly cooling hot foods to safe storage temperatures, enhancing food safety and quality in commercial kitchens.

All models in the Traulsen RBC series are equipped with adjustable shelving, allowing flexibility in storage solutions. The user-friendly digital display and controls facilitate temperature monitoring and adjustments, ensuring that food remains at safe and optimal temperatures.