Whirlpool W10292167D Venting Requirements, ventedmodels only, Cabinet Dimensions, Makeup Air

Page 5
Cabinet Dimensions

**27¹⁄₈" (68.9 cm) min. **41¹⁄₈" (104.5 cm) max.

*27¹⁄₈" (68.9 cm) min.

*45¹⁄₂" (115.6 cm) max.

17³⁄₁₆" (43.7 cm)

*For non-vented (recirculating) installations

**For vented installations

Cabinet Dimensions

10" (25.4 cm) min. 13" (33.0 cm) max.

2" (5.1 cm) min.

MPORTANT:9" (22.9 cm) min.* 9¹⁄₂" (24.1 cm) Venting Requirements(ventedmodels only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent and power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10" (25.4 cm) min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply cable

 

13" (33.0 cm) max.

 

 

 

 

 

 

 

 

 

entry location

 

 

 

 

 

 

 

 

 

20" (50.8

cm)* min.

 

Side

 

 

 

 

 

 

 

 

 

 

Side

 

cabinet

 

30" (76.2 cm) or

cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36" (91.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“X” bottom of canopy to cooking surface

Centerline

Cooking surface

*For non-vented (recirculating) installations

MPORTANT:

Minimum distance “X”: 24" (61.0 cm) from electric cooking surface

Minimum distance “X”: 27" (68.6 cm) from gas cooking surface

Suggested maximum distance “X”: 36" (91.4 cm)

For vented installations, the chimneys can be adjusted for ceilings between 7' 4" (2.25 m) and 9' 5" (2.87 m) with vent slots not showing and between 7' 4" (2.25 m) and 9' 9" (2.97 m) with the vent slots showing.

For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 7' 4" (2.24 m) and 9' 9" (2.97 m).

*NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10294735 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

Venting Requirements

(ventedmodels only)

Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

This canopy hood is factory set for venting through the roof or wall.

A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

5

Image 5
Contents Installation Instructions and Use & Care Guide 30 76.2 CM AND 36 91.4 CM WALL-MOUNT CANOPYInstructions d’installation et Guide d’utilisation et d’entretien RANGE HOODYour safety and the safety of others are very important RANGE HOOD SAFETYTABLE DES MATIÈRES DANGERREAD AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSTools and Parts INSTALLATION REQUIREMENTSLocation Requirements For Mobile Home InstallationsCabinet Dimensions Venting RequirementsCold Weather Installations ventedmodels onlyFor Non-Vented recirculating Installations Electrical RequirementsCalculating Vent System Length Example vent systemPrepare Location INSTALLATION INSTRUCTIONSVent Cover Bracket Installation Range Hood Mounting Screws InstallationConnect Vent System Install Range HoodFor vented installations only For non-vented recirculating installation onlyMake Electrical Connection Install Vent CoversElectrical Shock Hazard Disconnect power before servicing Connect ground wire to green and yellow ground wire in terminal boxRANGE HOOD USE Complete InstallationRange Hood Controls Operating the lightRANGE HOOD CARE CleaningNon-Vented recirculating Installation Filters Cleaning MethodGND L N WIRING DIAGRAMAccessories ASSISTANCE OR SERVICEIn the U.S.A In CanadaLIMITED WARRANTY WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTYITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIESVotre sécurité et celle des autres est très importante SÉCURITÉ DE LA HOTTE DE CUISINIÈREDANGER AVERTISSEMENT LIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences d’emplacement EXIGENCES DINSTALLATIONOutils et pièces Installation dans une résidence mobileDimensions du produit Exigences concernant l’évacuationDimensions du placard seulement pour unmodèle avecdécharge àlextérieurInstallation sans décharge à lextérieur recyclage Installation dans une région à climat froidInstallation sans Air dappointPréparation de lemplacement INSTRUCTIONS DINSTALLATIONAVERTISSEMENT Spécifications électriquesRaccordement du circuit dévacuation Installation de la hotteInstallation de la bride de cache-conduit Pour installations avec décharge à l’extérieur uniquementRisque de choc électrique Raccordement électriqueDéconnecter la source de courant électrique avant lentretien Replacer pièces et panneaux avant de faire la remise en marcheAchever l’installation Installation des cache-conduitsUTILISATION DE LA HOTTE Risque de choc électrique Relier le ventilateur à la terreENTRETIEN DE LA HOTTE Commandes de la hotte de cuisinièreNettoyage Filtres dinstallation sans décharge à l’extérieur recyclageRemplacement d’une lampe Terre L Neu SCHÉMA DE CÂBLAGEAccessoires ASSISTANCE OU SERVICEGARANTIE DES GROS APPAREILS MÉNAGERS WHIRLPOOL CORPORATION Au CanadaW10292167D