Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Remove terminal box cover.
3.Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief.
A
B
A.Knockout
B.Terminal box cover
4.Run home power supply cable through strain relief, into terminal box.
A B
C
D
EF
A.Home power supply cable
B.UL listed or CSA approved strain relief
C.Black wires
D.UL listed wire connectors
E.White wires
F. Green (or bare) and
5.Use UL listed wire connectors and connect black wires (C) together.
6.Use UL listed wire connectors and connect white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
7.Connect green (or bare) ground wire from home power supply to
8.Tighten strain relief screw.
9.Install terminal box cover.
10.Check that all light bulbs are secure in their sockets.
11.Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with 2 - 4 x 8 mm screws.
NOTE: For vented installations, the upper vent cover may be reversed to hide slots.
B
A
C
A.Bracket
B.4 x 8 mm screws
C.Vent cover
9