Cornelius 2232MS service manual CO2/AIR and Syrup Systems Flow Diagram

Page 16

AIR COMPRESSOR KIT (OPTIONAL)

CONDENSATION

DRAIN TUBE

CONDENSATION

TANK

CONNECT TO CARBONATORS

CO2 REGULATOR ASS’Y

TO CO2 CYLINDER

KIT (OPTIONAL)

 

CO2/AIR CHANGEOVER

VALVE

BULK CO2 TANK CONNECTION

(STANDARD INSTALLATION)

SHAKE

MACHINE

CO2/AIR CHANGEOVER

VALVE

SUGAR BASED SYRUP

(60–PSI) (4.14 BARS)

DIET SYRUP

(12–PSI) (.83 BARS

CO2 CHECK VALVE

SYRUP TANK KIT (OPTIONAL)

CONNECT

TO

DISPENSING

STATIONS

CO2/AIR CHANGEOVER

TO

VALVE

DISPENSERS

AIR PRESSURE

FINE FILTER

REGULATOR

 

AND COURSE

 

FILTER

 

*THE STANDARD INSTALLATION EMPLOYS THE USE OF A BULK SYRUP TANK WHICH

IS CONNECTED TO FOUR OF THE DISPENSERS SYRUP INLET LINES. OPTIONAL SYRUP TANKS KIT PROVIDES THE MEANS TO CONNECT FOUR SYRUP TANKS INSTEAD OF THE BULK SYRUP TANK.

LINE LEGEND

CO2/AIR

SYRUP

ORANGE

SPRITE

DIET

FROM BULK SYRUP TANK (STANDARD INSTALLATION)

FIGURE 7. CO2/AIR AND SYRUP SYSTEMS FLOW DIAGRAM

 

15

0713

Image 16
Contents Manfactured IMI Cornelius INC ANOKA, Minnesota This Document Contains Important InformationGeneral Warranty Policy General DescriptionTerms and Conditions Ordering InformationDistribution Centers Complete ServiceIMI Cornelius Inc Specifications Installation Installing POST-MIX DispensersInstalling Beverage Control Panel Assembly Loose-Shipped Parts Name QtyFastening Beverage Control Panel Assembly to Wall Make Sure ALL Lines are Labeled for IdentificationPreparation for Operation No TAG0713 Sealing Ends of Floor Chase if Applicable Standard Beverage Control Panel ASS’Y Water Pressure Pressure Switch Check Water Valve Surge Tank Water Pump Pressure Switch Check Check Valve Water Pump PRE Filet BUN CO2/AIR and Syrup Systems Flow Diagram Sprite Diet Orange Coke Conn NBR Description QTY Sprite Diet Orange Coke Bulk Tank Conn NBR Description QTY Sprite Diet Orange Syrup Bulk Tank Conn NBR Description QTY Diet sprite coke Conn NBR Description QTY Service and Maintenance POST-MIX Dispenser Service and MaintenanceBeverage Control Panel Assembly Service Maintenance Hazard in the water systemAlways Install NEW Ball Seat Quadding P/N Pressure Switch Liquid Check Valve Water Pump MotorSwitch Cleaning Optional Syrup Lines Strainers see Figure BarsSanitizing Syrup Systems Replenishing CO2 SupplyReplenishing Syrup Supply Cause serious personal injurySyrup Flavor Change Troubleshooting CYCLES’’ CON’T Water Inlet PressureGauge Reads TOO LOW Gauge Reads TOO HighNot Operate CON’T AIR Compressor ‘SHORTDispensed Drinks have ‘OFF’’ TasteWiring Diagram Carbonator Instructions for Crimping Tube Clamps Beverage Control Panel ASS’Y Beverage Control Panel ASS’Y CO2 Regulator ASS’Y P/N No. Part No Name CO2 Check Valve ASS’Y P/N NameCO2 Regulator ASS’Y Check Valve and Manifold ASS’Y P/N Large Reserve Carbonator Large Reserve Carbonator Water Manifold ASS’Y P/N Pump and Motor ASS’Y Regulator ASS’Y, HI-PRESSURE P/N Warranty