Cornelius 2232MS service manual Troubleshooting

Page 31

TROUBLESHOOTING

IMPORTANT: Only qualified personnel should service internal components or electrical wiring.

WARNING: If repairs are to be made to carbonated water system, disconnect electrical power to Cooling Unit, shut off plain water and CO2 supplies, and relieve the carbonated water system pressure before proceeding. If repairs are to be made to syrup system,

remove quick disconnects from applicable syrup tank, then relieve the system pressure before proceeding. If repairs are to be made to CO2 system, stop dispensing, shut off CO2 supply, then relieve the system pressure before proceeding.

If repairs are to be made to an existing Remote Condensing unit, disconnect the power to the condensing unit before proceeding

TROUBLESHOOTING OPTIONAL WATER PRESSURE BOOSTER SYSTEM

Trouble

 

Probable Cause

Remedy

WATER PUMP NOT

A.

Power cord unplugged from

A. Plug power cord into electrical

OPERATING

 

electrical outlet.

outlet.

 

B. Electrical circuit fuse blown or

B. Replace fuse or reset circuit

 

 

circuit breaker tripped.

breaker.

 

C.

Water pump motor inoperative

C. Have Service Technician replace

 

 

 

inoperative moto

 

D. Water pump pressure switch

D. Have Service Technician replace

 

 

inoperative.

inoperative pressure switch.

 

E.

Thermal overload switch

E. Have Service Technician replace

 

 

inoperative.

inoperative thermal overload

 

 

 

switch.

F.Plain water inlet pressure above 60–PSI (4.14 Bars).

F.Have Service Technician reset ‘‘CUT IN’’ pressure on pressure switch to 10–PSI (.68 Bars) above water inlet pressure.

WATER PUMP

A. Water tank is overcharged with

A. Evacuate all water from Beverage

‘‘SHORTCYCLES’’

air, CO2 or nitrogen gas.

Support System. Adjust pressure

 

 

to 40 ± 5–PSI (2.76 ± .34 Bars),

 

 

then reactivate system.

 

B. Check to see if check valve on

B. Disassemble and clean check

 

water pump outlet is leaking

valve. If valve is damaged,

 

water

replace.

 

C. Water tank shutoff valve is

C. Open water tank shutoff valve

 

closed

 

 

D. Water pump pressure switch is

D. Have Service Technician readjust

 

not correctly adjusted.

the pump pressure switch.

 

 

 

WATER PUMP ‘‘LONG

A.

Water tank is undercharged

CYCLES’’

 

with air, CO2, or nitrogen gas.

 

B.

Water tank gas bladder is

 

 

leaking.

A.Evacuate all water from Beverage

Support System. Adjust gas pressure to 40 ± 5 PSI, (2.76 ±

.34 Bars) then reactivate system.

B.Replace water tank, pressurize gas pressure to 40 ± 5–PSI (2.76

± .34 Bars), then reactivate.

30

0713

Image 31
Contents This Document Contains Important Information Manfactured IMI Cornelius INC ANOKA, MinnesotaOrdering Information General Warranty PolicyGeneral Description Terms and ConditionsDistribution Centers Complete ServiceIMI Cornelius Inc Specifications Loose-Shipped Parts Name Qty InstallationInstalling POST-MIX Dispensers Installing Beverage Control Panel AssemblyMake Sure ALL Lines are Labeled for Identification Fastening Beverage Control Panel Assembly to WallNo TAG Preparation for Operation0713 Sealing Ends of Floor Chase if Applicable Standard Beverage Control Panel ASS’Y Water Pressure Pressure Switch Check Water Valve Surge Tank Water Pump Pressure Switch Check Check Valve Water Pump PRE Filet BUN CO2/AIR and Syrup Systems Flow Diagram Sprite Diet Orange Coke Conn NBR Description QTY Sprite Diet Orange Coke Bulk Tank Conn NBR Description QTY Sprite Diet Orange Syrup Bulk Tank Conn NBR Description QTY Diet sprite coke Conn NBR Description QTY Hazard in the water system Service and MaintenancePOST-MIX Dispenser Service and Maintenance Beverage Control Panel Assembly Service MaintenancePressure Switch Liquid Check Valve Water Pump Motor Always Install NEW Ball Seat Quadding P/NSwitch Bars Cleaning Optional Syrup Lines Strainers see FigureCause serious personal injury Sanitizing Syrup SystemsReplenishing CO2 Supply Replenishing Syrup SupplySyrup Flavor Change Troubleshooting Gauge Reads TOO High CYCLES’’ CON’TWater Inlet Pressure Gauge Reads TOO LOW‘OFF’’ Taste Not Operate CON’TAIR Compressor ‘SHORT Dispensed Drinks haveWiring Diagram Carbonator Instructions for Crimping Tube Clamps Beverage Control Panel ASS’Y Beverage Control Panel ASS’Y CO2 Regulator ASS’Y P/N CO2 Check Valve ASS’Y P/N Name No. Part No NameCO2 Regulator ASS’Y Check Valve and Manifold ASS’Y P/N Large Reserve Carbonator Large Reserve Carbonator Water Manifold ASS’Y P/N Pump and Motor ASS’Y Regulator ASS’Y, HI-PRESSURE P/N Warranty

2232MS specifications

The Cornelius 2232MS is an advanced beverage dispensing system that combines cutting-edge technology with user-friendly features, making it an ideal choice for various commercial settings, such as restaurants, bars, and convenience stores. This model stands out due to its impressive performance and innovative design, which cater to the diverse needs of beverage service.

One of the key features of the Cornelius 2232MS is its high-capacity dispensing capability. The system can accommodate a wide range of beverage types, including carbonated soft drinks, teas, and flavored syrups. This versatility allows businesses to offer a broader menu, appealing to a wider customer base. The dispensers are designed to handle multiple flavors simultaneously, ensuring that patrons can enjoy their favorite drinks without long wait times.

Technology plays a critical role in the operation of the Cornelius 2232MS. The system is equipped with an advanced touchless dispensing interface, which minimizes the risk of cross-contamination and promotes a hygienic environment. Users can easily select their preferred beverage with just a touch, making the experience both efficient and enjoyable. Additionally, the unit features programmable settings that allow operators to customize drink proportions and carbonic acid levels, ensuring consistent quality in every pour.

Another notable characteristic of the Cornelius 2232MS is its energy-efficient design. The system utilizes eco-friendly technology that reduces power consumption, making it an environmentally responsible option for businesses. This energy efficiency not only contributes to cost savings on utility bills but also aligns with modern sustainability goals.

Maintenance and serviceability are also prioritized in the design of the Cornelius 2232MS. The unit features easy-to-access components for cleaning and servicing, which minimizes downtime. Regular maintenance can be performed with minimal effort, ensuring that the system remains in optimal condition for prolonged use.

In conclusion, the Cornelius 2232MS stands out in the beverage dispensing market due to its versatility, cutting-edge technology, and energy efficiency. Its user-friendly interface and easy maintenance make it a practical choice for any business looking to elevate their beverage service. With the Cornelius 2232MS, operators can expect enhanced customer satisfaction and improved operational efficiency, solidifying its position as a leader in beverage dispensing solutions.