Cornelius 2232MS service manual Fastening Beverage Control Panel Assembly to Wall

Page 6

6.Connect one end of TUBE ASS’Y (item 33) to water surge tank elbow assembly 3/8–inch flare (5/8–18) fitting as shown in applicable Figure 3, 4, 5, or 6. Seal connection with TAPERED GASKET, BLACK (item 4).

7.Connect other end of tube assembly to water manifold assembly 3/8–inch flare (5/8–18) fitting on water filter assembly (see applicable Figure 3, 4, 5, or 6). Seal connection with TAPERED GASKET, BLACK (item 4).

FASTENING BEVERAGE CONTROL PANEL ASSEMBLY TO WALL

WARNING: The Beverage Control Panel Assembly must be securely fastened to the wall before

connecting the assembly into the system. The Beverage Control Panel Assembly must be fastened to the wall with six fasteners provided by the Installer) and each fastener must be capable of resisting a 200 pound (90.7 KG) pull. Be very careful when handling the assembly as it is very top heavy and could fall and cause serious personal injury and also equipment damage.

CONNECTING SUGAR–BASE SYRUP TANKS CO2 LINES TO BEVERAGE CONTROL PANEL ASSEMBLY CO2 MANIFOLD

(see Figure 7)

1.Using .265 I.D. tubing, fittings, gas quick disconnects, and tubing clamps, provided in the installation kit, make up three gas lines to be

connected between the CO2 manifold and the sugar–base syrup tanks.

2.Connect three gas lines swivel nut ends to CO2 check valves on Beverage Control Panel

Assembly CO2 manifold. Seal connections with white tapered gaskets.

CONNECTING DIET SYRUP TANK CO2 LINE TO BEVERAGE CONTROL PANEL ASSEMBLY DIET SYRUP CO2 REGULATOR.

(see Figure 7)

3.Using .265 I.D. tubing, fittings, gas quick disconnect, and tubing clamps, make up one gas line to be connected between the Beverage Control Panel Assembly diet–syrup tank.

4.Connect swivel nut end of gas line to check

valve on outlet of the diet–syrup tank CO2 regulator. Seal connection with white tapered gasket.

Refer to instructions in previous WARNING note and secure Beverage Control Panel Assembly to wall as follows:

1.Very carefully, lay panel assembly upper frame over on its back side. Slide telescoping lower frame up on panel assembly upper frame.

2.Very carefully, lift Beverage Control Panel Assembly up and place in position up against wall.

3.Using screw adjusters on bottoms of Legs, adjust until Control Panel Assembly sits level.

4.Secure Control Panel Assembly to wall with six fasteners provided by the installer.

5.Using .156 I.D. tubing provided in installation kit, connect one end of tubing to vented double check valve (see applicable Figure 3, 4, 5, or 6), then route other end of tubing to a permanent floor drain.

6.Fasten tubing to frame assembly with wire ties provided in installation kit.

CONNECTING BEVERAGE CONTROL PANEL ASSEMBLY TO POST–MIX DISPENSER(S) AND OTHER EQUIPMENT TO BE CONNECTED TO THE SYSTEM

(see Figure 7)

NOTE: The syrup, plain and carbonated water and CO2 lines to the Post–Mix Dispenser(s) and various other equipment at the installation site may be routed overhead or through a floor chase from the Beverage Control Panel Assembly.

MAKE SURE ALL LINES ARE LABELED FOR IDENTIFICATION.

Refer to manual(s) provided with the Post–Mix Dispenser(s) to connect plain water, carbonated water, and syrup lines to the Dispenser(s).

Center–Island Installation with Optional Syrup Tanks Hookup (see Figure NO TAG)

Connect CO2, plain water, carbonated water, and syrup lines between Beverage Control Panel Assembly, the Post–Mix Dispenser, and other equipment to be connected to the system. Optional syrup tanks Kit (P/N 0673) is used to connect four syrup tanks into system.

Connect insulated plain water line between plain water line connected to Post–Mix Dispenser cold plate and the Orange Juice Dispenser.

5

0713

 

Image 6
Contents Manfactured IMI Cornelius INC ANOKA, Minnesota This Document Contains Important InformationTerms and Conditions General Warranty PolicyGeneral Description Ordering Information Complete Service Distribution Centers IMI Cornelius Inc Specifications Installing Beverage Control Panel Assembly InstallationInstalling POST-MIX Dispensers Loose-Shipped Parts Name QtyFastening Beverage Control Panel Assembly to Wall Make Sure ALL Lines are Labeled for IdentificationPreparation for Operation No TAG0713 Sealing Ends of Floor Chase if Applicable Standard Beverage Control Panel ASS’Y Water Pressure Pressure Switch Check Water Valve Surge Tank Water Pump Pressure Switch Check Check Valve Water Pump PRE Filet BUN CO2/AIR and Syrup Systems Flow Diagram Sprite Diet Orange Coke Conn NBR Description QTY Sprite Diet Orange Coke Bulk Tank Conn NBR Description QTY Sprite Diet Orange Syrup Bulk Tank Conn NBR Description QTY Diet sprite coke Conn NBR Description QTY Beverage Control Panel Assembly Service Maintenance Service and MaintenancePOST-MIX Dispenser Service and Maintenance Hazard in the water systemAlways Install NEW Ball Seat Quadding P/N Pressure Switch Liquid Check Valve Water Pump MotorSwitch Cleaning Optional Syrup Lines Strainers see Figure BarsReplenishing Syrup Supply Sanitizing Syrup SystemsReplenishing CO2 Supply Cause serious personal injurySyrup Flavor Change Troubleshooting Gauge Reads TOO LOW CYCLES’’ CON’TWater Inlet Pressure Gauge Reads TOO HighDispensed Drinks have Not Operate CON’TAIR Compressor ‘SHORT ‘OFF’’ TasteWiring Diagram Carbonator Instructions for Crimping Tube Clamps Beverage Control Panel ASS’Y Beverage Control Panel ASS’Y CO2 Regulator ASS’Y P/N No. Part No Name CO2 Check Valve ASS’Y P/N NameCO2 Regulator ASS’Y Check Valve and Manifold ASS’Y P/N Large Reserve Carbonator Large Reserve Carbonator Water Manifold ASS’Y P/N Pump and Motor ASS’Y Regulator ASS’Y, HI-PRESSURE P/N Warranty