6.Connect one end of TUBE ASS’Y (item 33) to water surge tank elbow assembly
7.Connect other end of tube assembly to water manifold assembly
FASTENING BEVERAGE CONTROL PANEL ASSEMBLY TO WALL
WARNING: The Beverage Control Panel Assembly must be securely fastened to the wall before
connecting the assembly into the system. The Beverage Control Panel Assembly must be fastened to the wall with six fasteners provided by the Installer) and each fastener must be capable of resisting a 200 pound (90.7 KG) pull. Be very careful when handling the assembly as it is very top heavy and could fall and cause serious personal injury and also equipment damage.
CONNECTING
(see Figure 7)
1.Using .265 I.D. tubing, fittings, gas quick disconnects, and tubing clamps, provided in the installation kit, make up three gas lines to be
connected between the CO2 manifold and the
2.Connect three gas lines swivel nut ends to CO2 check valves on Beverage Control Panel
Assembly CO2 manifold. Seal connections with white tapered gaskets.
CONNECTING DIET SYRUP TANK CO2 LINE TO BEVERAGE CONTROL PANEL ASSEMBLY DIET SYRUP CO2 REGULATOR.
(see Figure 7)
3.Using .265 I.D. tubing, fittings, gas quick disconnect, and tubing clamps, make up one gas line to be connected between the Beverage Control Panel Assembly
4.Connect swivel nut end of gas line to check
valve on outlet of the
Refer to instructions in previous WARNING note and secure Beverage Control Panel Assembly to wall as follows:
1.Very carefully, lay panel assembly upper frame over on its back side. Slide telescoping lower frame up on panel assembly upper frame.
2.Very carefully, lift Beverage Control Panel Assembly up and place in position up against wall.
3.Using screw adjusters on bottoms of Legs, adjust until Control Panel Assembly sits level.
4.Secure Control Panel Assembly to wall with six fasteners provided by the installer.
5.Using .156 I.D. tubing provided in installation kit, connect one end of tubing to vented double check valve (see applicable Figure 3, 4, 5, or 6), then route other end of tubing to a permanent floor drain.
6.Fasten tubing to frame assembly with wire ties provided in installation kit.
CONNECTING BEVERAGE CONTROL PANEL ASSEMBLY TO
(see Figure 7)
NOTE: The syrup, plain and carbonated water and CO2 lines to the
MAKE SURE ALL LINES ARE LABELED FOR IDENTIFICATION.
Refer to manual(s) provided with the
Connect CO2, plain water, carbonated water, and syrup lines between Beverage Control Panel Assembly, the
Connect insulated plain water line between plain water line connected to