Cornelius 2232MS service manual Regulator ASS’Y, HI-PRESSURE P/N

Page 46

2

6

4

3

4

5

4

1

4

5

Item

 

 

No.

Part No.

Name

 

 

 

1

311904

Changeover Valve

 

 

 

2

0606

Regulator Ass’y (see Figure 5-17)

 

 

 

3

176065

Fitting, Swivel, 7/16-20

 

 

 

4

178025-100

Tapered Gasket, White

 

 

 

5

310822

Fitting, 7/16-20

 

 

 

6

176168-100

Fitting, 1/4 NPT By 7/16-20

 

 

 

*zinc Plated Steel Unless Otherwise Indicated.

FIGURE 32. REGULATOR ASS’Y, HI-PRESSURE (P/N 0650)

2

 

 

 

Item

 

 

 

6

 

No.

Part No.

Name

 

7

 

 

 

 

 

8

 

1

183586

Regulator ass’y (see Figure 5-6)

 

 

 

 

 

 

2

183285

Gauge, 160 PSI

 

5

 

3

183267

Gauge, 1800 PSI

 

 

 

 

 

 

9

 

4

183061

Fitting, 1/4 NPT By 7/16-20

 

11

10

 

 

 

 

 

 

 

5

183334

Fitting 1/4 NPT By 7/16-20

 

 

 

6

183317

Bracket, Regulator

3

 

 

7

*183040

Machine Screw, Phil Fil HD, No. 10-32

 

 

 

 

 

By 7/8” Long

 

 

 

8

*321811

Hex Nut, NO. 10-32

1

4

 

9

176168-100

Fitting 1/4 NPT By 7/16-20

 

 

 

 

 

 

10

187485

Fitting, 1/4 NPT By 7/16-20

 

 

 

11

178025-100

Tapered Gasket, White

 

 

 

*Zinc Plated Steel Unless Otherwise Indicated.

 

FIGURE 33. REGULATOR ASS’Y (P/N 0606)

 

2

 

 

 

 

 

 

 

Item

 

 

 

1

 

No.

Part No.

Name

 

 

1

317928

Regulator

4

2

 

 

 

 

 

 

 

2

0711

Fitting

 

 

3

 

 

 

 

 

 

 

 

3

0712

Fitting

 

 

 

4

1301

Fitting, 1/2 NPT

FIGURE 34. OPTIONAL WATER PRESSURE REGULATOR KIT (P/N 300919-000)

45

0713

 

Image 46
Contents Manfactured IMI Cornelius INC ANOKA, Minnesota This Document Contains Important InformationTerms and Conditions General Warranty PolicyGeneral Description Ordering InformationDistribution Centers Complete ServiceIMI Cornelius Inc Specifications Installing Beverage Control Panel Assembly InstallationInstalling POST-MIX Dispensers Loose-Shipped Parts Name QtyFastening Beverage Control Panel Assembly to Wall Make Sure ALL Lines are Labeled for IdentificationPreparation for Operation No TAG0713 Sealing Ends of Floor Chase if Applicable Standard Beverage Control Panel ASS’Y Water Pressure Pressure Switch Check Water Valve Surge Tank Water Pump Pressure Switch Check Check Valve Water Pump PRE Filet BUN CO2/AIR and Syrup Systems Flow Diagram Sprite Diet Orange Coke Conn NBR Description QTY Sprite Diet Orange Coke Bulk Tank Conn NBR Description QTY Sprite Diet Orange Syrup Bulk Tank Conn NBR Description QTY Diet sprite coke Conn NBR Description QTY Beverage Control Panel Assembly Service Maintenance Service and MaintenancePOST-MIX Dispenser Service and Maintenance Hazard in the water systemAlways Install NEW Ball Seat Quadding P/N Pressure Switch Liquid Check Valve Water Pump MotorSwitch Cleaning Optional Syrup Lines Strainers see Figure BarsReplenishing Syrup Supply Sanitizing Syrup SystemsReplenishing CO2 Supply Cause serious personal injurySyrup Flavor Change Troubleshooting Gauge Reads TOO LOW CYCLES’’ CON’TWater Inlet Pressure Gauge Reads TOO HighDispensed Drinks have Not Operate CON’TAIR Compressor ‘SHORT ‘OFF’’ TasteWiring Diagram Carbonator Instructions for Crimping Tube Clamps Beverage Control Panel ASS’Y Beverage Control Panel ASS’Y CO2 Regulator ASS’Y P/N No. Part No Name CO2 Check Valve ASS’Y P/N NameCO2 Regulator ASS’Y Check Valve and Manifold ASS’Y P/N Large Reserve Carbonator Large Reserve Carbonator Water Manifold ASS’Y P/N Pump and Motor ASS’Y Regulator ASS’Y, HI-PRESSURE P/N Warranty