Connect CO2, plain water, carbonated water, and syrup lines between Beverage Control Panel Assembly, the
Connect insulated plain water line between plain water line connected to
Connect CO2, plain water, carbonated water, and syrup lines between Beverage Control Panel Assembly, the
Connect insulated plain water line between plain water line connected to
Connect CO2, plain water, carbonated water and syrup lines between Beverage Control Panel Assembly, the
Connect insulated plain water line between plain water line connected to
PREPARATION FOR OPERATION
BEVERAGE CONTROL PANEL ASSEMBLY
NOTE: The Beverage Control Panel Assembly must be connected to a water source with water pressure between 45 and
IMPORTANT: DO NOT operate (if applicable) the Optional Water Pressure Booster water pump with no water connected to the Beverage Control Panel Assembly. Operating water pump dry will void its factory warranty.
1.Install
2.Make sure all shutoff valves on water manifold assembly and water filter assembly are in ‘‘OFF’’ position.
IMPORTANT: DO NOT operate carbonator(s) water pump(s) or water pressure booster system (if applicable) water pump with no water in the system. Operating pumps dry will cause damage to the pumps which will void their factory warranty.
3.Connect plain water source line, meeting requirements of preceding NOTE, to Beverage Control Panel Assembly.
4.Open Beverage Control Panel Assembly plain water source shutoff valve.
5.Beverage Control Panel Assembly equipped with Everpure water filters (see applicable Figure 3 or 5).
A.Connect length of garden hose to FILTER ‘‘ACTIVATION VALVE,’’ then route hose to a permanent drain.
B.Open ‘‘ACTIVATION VALVE’’ and allow approximately
6.Standard Installation (see Figure 7).
WARNING: CO2 Displaces Oxygen. Strict Attention must be observed in the prevention of CO2 (carbon
dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
Connect bulk CO2 tank CO2 supply line to barbed fitting on CO2 manifold. Secure connection with tubing clamp.
Installation employing the optional
WARNING: To avoid personal injury and/or property damage, always
secure CO2 cylinders with safety chain to prevent them from falling over. Should the valve become accidentally damaged of broken off, CO2 cylinder can cause serious personal injury.
6 | 0713 |
|