FIGURE 16. SYRUP LINE STRAIANER
1.Using
2.Disconnect syrup out quick disconnects, containing the syrup strainers, from all syrup tanks.
3.Activate all dispensing valves on Dispensers to relieve pressure from all syrup systems.
4.Loosen syrup strainer screen (see Figure
5.Pull screen from screen retainer. Inspect screen for holes, restrictions, corrosion, and any other damage. Discard damaged screen and replace with a new one.
6.Place quick disconnect and syrup strainer housing in bucket containing sanitizing solution. Thoroughly wash quick disconnect and syrup strainer housing, screen retainer, and screen in sanitizing solution.
7.Thoroughly rinse quick disconnect and syrup strainer housing, screen retainer and screen with potable water.
8.Install screen in screen retainer, then screw screen retainer into water strainer housing. Tighten retainer only finger tight.
9.Repeat steps 4) through 8) to clean and sanitize remaining syrup strainers.
10. Sanitize all syrup systems as instructed.
11.Connect syrup out quick disconnects to all syrup tanks.
WATER FILTERS REPLACEMENT
Refer to Water Filtration System manual for water filters replacement instructions.
SANITIZING SYRUP SYSTEMS
The syrup systems should be sanitized every
REPLENISHING CO2 SUPPLY
NOTE: When indicator on CO2 cylinder regulator assembly
1.Fully close (clockwise) CO2 cylinder valve.
2.Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove regulator assembly from empty CO2 cylinder.
3.Unfasten safety chain and remove empty CO2 cylinder.
WARNING: To avoid personal injury and/or property damage, always secure CO2 cylinder with safety chain to prevent if from falling over. Should the valve become acciden- tally damaged or broken off, CO2 cylinder can
cause serious personal injury.
4.Position CO2 cylinder and secure with safety chain.
5.Make sure gasket is in place inside CO2 regulator coupling nut, then install regulator on CO2 cylinder.
6.Open (counterclockwise) CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open valve fully to
7.Check CO2 connections for leaks. Tighten loose connections.
REPLENISHING SYRUP SUPPLY
WARNING: To avoid personal injury or property damage, do not attempt to re- move syrup tank cover until CO2 pressure has
been released from tank.
28 | 0713 |
|