Cornelius 2232MS Sanitizing Syrup Systems, Replenishing CO2 Supply, Replenishing Syrup Supply

Page 29

FIGURE 16. SYRUP LINE STRAIANER

1.Using chlor–tergent (Oakite Products, Inc.) or equivalent sanitizer and LUKEWARM water, mix 2–1/2 gallons (9.46 liters) of sanitizing solution in a bucket.

2.Disconnect syrup out quick disconnects, containing the syrup strainers, from all syrup tanks.

3.Activate all dispensing valves on Dispensers to relieve pressure from all syrup systems.

4.Loosen syrup strainer screen (see Figure 3–5) retainer, then pull syrup strainer and screen from syrup strainer housing.

5.Pull screen from screen retainer. Inspect screen for holes, restrictions, corrosion, and any other damage. Discard damaged screen and replace with a new one.

6.Place quick disconnect and syrup strainer housing in bucket containing sanitizing solution. Thoroughly wash quick disconnect and syrup strainer housing, screen retainer, and screen in sanitizing solution.

7.Thoroughly rinse quick disconnect and syrup strainer housing, screen retainer and screen with potable water.

8.Install screen in screen retainer, then screw screen retainer into water strainer housing. Tighten retainer only finger tight.

9.Repeat steps 4) through 8) to clean and sanitize remaining syrup strainers.

10. Sanitize all syrup systems as instructed.

11.Connect syrup out quick disconnects to all syrup tanks.

WATER FILTERS REPLACEMENT

Refer to Water Filtration System manual for water filters replacement instructions.

SANITIZING SYRUP SYSTEMS

The syrup systems should be sanitized every

90–days using Chlor–Tergent (Oakite Products, Inc.) or equivalent sanitizer. Refer to manual provided with the Post–Mix Dispenser for sanitizing instructions.

REPLENISHING CO2 SUPPLY

NOTE: When indicator on CO2 cylinder regulator assembly 1800–PSI (124.1 Bars) gauge is in shaded (‘‘Change CO2 Cylinder’’) portion of dial, CO2 cylinder is almost empty and should be changed.

1.Fully close (clockwise) CO2 cylinder valve.

2.Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove regulator assembly from empty CO2 cylinder.

3.Unfasten safety chain and remove empty CO2 cylinder.

WARNING: To avoid personal injury and/or property damage, always secure CO2 cylinder with safety chain to prevent if from falling over. Should the valve become acciden- tally damaged or broken off, CO2 cylinder can

cause serious personal injury.

4.Position CO2 cylinder and secure with safety chain.

5.Make sure gasket is in place inside CO2 regulator coupling nut, then install regulator on CO2 cylinder.

6.Open (counterclockwise) CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open valve fully to back–seat valve. (Back–seating valve prevents leakage around valve shaft).

7.Check CO2 connections for leaks. Tighten loose connections.

REPLENISHING SYRUP SUPPLY

WARNING: To avoid personal injury or property damage, do not attempt to re- move syrup tank cover until CO2 pressure has

been released from tank.

28

0713

 

Image 29
Contents This Document Contains Important Information Manfactured IMI Cornelius INC ANOKA, MinnesotaGeneral Description General Warranty PolicyTerms and Conditions Ordering InformationIMI Cornelius Inc Complete ServiceDistribution Centers Specifications Installing POST-MIX Dispensers InstallationInstalling Beverage Control Panel Assembly Loose-Shipped Parts Name QtyMake Sure ALL Lines are Labeled for Identification Fastening Beverage Control Panel Assembly to WallNo TAG Preparation for Operation0713 Sealing Ends of Floor Chase if Applicable Standard Beverage Control Panel ASS’Y Water Pressure Pressure Switch Check Water Valve Surge Tank Water Pump Pressure Switch Check Check Valve Water Pump PRE Filet BUN CO2/AIR and Syrup Systems Flow Diagram Sprite Diet Orange Coke Conn NBR Description QTY Sprite Diet Orange Coke Bulk Tank Conn NBR Description QTY Sprite Diet Orange Syrup Bulk Tank Conn NBR Description QTY Diet sprite coke Conn NBR Description QTY POST-MIX Dispenser Service and Maintenance Service and MaintenanceBeverage Control Panel Assembly Service Maintenance Hazard in the water system Pressure Switch Liquid Check Valve Water Pump Motor Always Install NEW Ball Seat Quadding P/NSwitch Bars Cleaning Optional Syrup Lines Strainers see FigureReplenishing CO2 Supply Sanitizing Syrup SystemsReplenishing Syrup Supply Cause serious personal injurySyrup Flavor Change Troubleshooting Water Inlet Pressure CYCLES’’ CON’TGauge Reads TOO LOW Gauge Reads TOO HighAIR Compressor ‘SHORT Not Operate CON’TDispensed Drinks have ‘OFF’’ TasteWiring Diagram Carbonator Instructions for Crimping Tube Clamps Beverage Control Panel ASS’Y Beverage Control Panel ASS’Y CO2 Regulator ASS’Y P/N CO2 Check Valve ASS’Y P/N Name No. Part No NameCO2 Regulator ASS’Y Check Valve and Manifold ASS’Y P/N Large Reserve Carbonator Large Reserve Carbonator Water Manifold ASS’Y P/N Pump and Motor ASS’Y Regulator ASS’Y, HI-PRESSURE P/N Warranty