INSTALLATION
This manual is intended to assist the installer and service personnel in the installation, operation, and maintenance procedures to be performed on the Beverage Control Panel Assembly (see Figure 1 and applicable Figure 3, 4, 5, or 6).
The Beverage Control Panel Assembly is designed to filter, pressure regulator, and distribute plain and carbonated water, CO2 gas, and syrup to the
If your Beverage Control Panel Assembly is equipped with either or both the optional air compressor kit or the water pressure booster kit, dedicated properly grounded electrical outlets with proper electrical requirements must also be located close to the Beverage Control Panel Assembly installation location to provide electrical power.
No other electrical equipment should be connected to these electrical circuits. ALL ELECTRICAL WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL CODES.
NOTE: The Beverage Control Panel Assembly is manufactured in America and has American sizes on the hardware. All metric conversion are approximate and vary in size.
NOTE: The Beverage Control Panel Assembly was thoroughly inspected before leaving the factory and the carrier has accepted and signed for it. Any damage or irregularities should be noted at the time of delivery (or not later than 15 days from date of deliver) and immediately reported to the delivering carrier. Request a written inspection report from Claims Inspector to substantiate any necessary claim. File claim with the delivering carrier, not with IMI Cornelius Inc.
INSTALLING POST–MIX DISPENSER(S)
Refer to manual(s) provided with the
INSTALLING BEVERAGE CONTROL PANEL ASSEMBLY
Your Beverage Control Panel Assembly may be equipped with one or more of the optional kits as shown in Figure 2. Figure 1 shows the standard Beverage Control Panel Assembly with no optional kits and Figure 2 shows the panel assembly with optional kits installed.
NOTE: A dedicated and properly grounded electrical outlet with proper electrical requirements must be located close to the Beverage Control Panel Assembly installation location to provide electrical power to (depending upon Beverage Control Panel Model Number) one or two carbonators.
Table 2. Loose-Shipped Parts
Item |
|
|
|
No. | Part No. | Name | Qty. |
|
|
|
|
1 | Water Surge Tank | 1 | |
|
|
|
|
2 | Strap, Surge Tank | 1 | |
|
|
|
|
3 | 300912 | Tube Ass’y, .375 I.D. | 1 |
|
| By |
|
|
|
|
|
4 | 311304 | Tapered Gasket, | 4 |
|
| Black |
|
|
|
|
|
5 | 0590 | Elbow Ass’y, Surge | 1 |
|
| Tank |
|
|
|
|
|
INSTALLING WATER SURGE TANK (ITEM 1) ON BEVERAGE CONTROL PANEL ASSEMBLY
NOTE: It is suggested for ease of assembly, that the
1.Install ELBOW ASS’Y SURGE TANK (item 5) in top of WATER SURGE TANK (item 1) as shown in Figure 17. Seal pipe thread connection with pipe sealing compound.
2.Refer to applicable Figure 1 or 2 for water surge tank location on Beverage Control Panel Assembly upper frame, then remove two
3.Position water surge tank in position on Beverage Control Panel Assembly.
4.Place STRAP, SURGE TANK (item 2) in position around water surge tank and align holes in strap with holes in frame where two
5.Secure strap to frame with two
4 | 0713 |
|