Estate W10121806C installation instructions Pilot and Bypass Screws Conversion

Page 14

Pilot and Bypass Screws Conversion

1.Remove control knobs and set aside.

2.Remove upper grates.

3.Lift the cooktop by both front corners until the side support rods snap into position.

4.Open oven door.

5.Locate the two top fasteners and two bottom fasteners and remove them using a Phillips head screwdriver.

A

B

A. Top fasteners

B. Bottom fasteners

6.Set the front panel aside and locate the oven thermostat.

A

A. Oven thermostat

7.Locate the Natural gas bypass screw in the bag containing literature included with the range. One LP gas bypass screw is stamped “76.”

8.Remove the LP gas bypass screw with a flat-blade screwdriver, turning counterclockwise.

9.Install the natrual gas bypass screw with a flat-blade screwdriver, turning clockwise.

A

B

A. Pilot screw

B. bypass screw

10.Locate the Natural gas pilot screw in the bag containing literature included with the range. One Natural gas pilot screw is stamped “94.”

11.Remove LP gas pilot screw with a flat-blade screwdriver, turning counterclockwise.

12.Install the Natural gas pilot screw with a flat-blade screwdriver, turning clockwise.

13.Replace the front panel and screw bottom and top fasteners in place.

14.Replace the control knobs. Push back on the side support rods and slowly lower the cooktop until it snaps into position. Close the oven door.

Complete Conversion

1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2.Turn the manual shutoff valve in the gas supply line to the open position.

3.Refer to the “Check Operation” section for proper burner ingnition, operation and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.

4.Close the broiler door and turn the knob to “OFF.”

5.Refer to the “Complete Installation” section to complete this procedure.

14

Image 14
Contents Table of Contents/Índice Range Safety Your safety and the safety of others are very importantLocation Requirements Installation RequirementsTools and Parts Mobile home installations require Product Dimensions Freestanding RangeCabinet Dimensions Gas Supply Requirements Line pressure testing above ½ psi gauge 14 WCP Installation InstructionsInstall Anti-Tip Bracket Line pressure testing at ½ psi gauge 14 WCP or lowerMake Gas Connection Typical rigid pipe connectionCheck Operation Level RangeVerify Anti-Tip Bracket Location If the low flame needs adjusting Check Operation of Oven/Broil BurnerIf you need Assistance or Service Complete InstallationIf the flame needs adjusting GAS ConversionsTo Convert Oven Burner To Convert Gas Pressure RegulatorTo Convert Surface Burners Natural Gas Conversion Pilot and Bypass Screws ConversionComplete Conversion To Convert Surface Burners Pilot and Bypass Screws Conversion Seguridad DE LA Estufa Requisitos de ubicación Requisitos DE InstalaciónPiezas y herramientas Las instalaciones en casas rodantes necesitan Medidas del producto Estufa autónomaEspacios libres para instalación Línea de suministro de gas Requisitos del suministro de gasTipo de gas Regulador de la presión de gasInstalación del soporte anti-vuelco Instrucciones DE InstalaciónDesempaque la estufa Prueba de presión del suministro de gasConexión del suministro de gas Verifique el funcionamiento Verificación de la ubicación del soporte Anti-vuelcoNivelación de la estufa Verifique el funcionamiento del quemador de asar/del horno Si la llama baja necesita ajustarseSi necesita ayuda o servicio técnico Complete la instalaciónSi la llama necesita ajustarse Si la estufa no funciona, revise lo siguienteCómo convertir el regulador de la presión del gas Conversiones DE GASConversión de gas LP Cómo convertir el quemador del horno Conversión de tornillos de desvío y pilotoCómo convertir los quemadores de superficie Complete la conversión Conversión de gas naturalEspitas de los orificios Válvulas Obturador de aire W10121806C