(formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Product Dimensions

Freestanding Range

26 3/4"

(67.9 cm)36"

(91.4 cm)

42"

(106.7 cm)

24 1/4"

29 7/8" (75.9 cm)

(61.6 cm)

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.

If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond cabinet fronts by ½" (13.0 mm) minimum.

IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

B D

C

A

E

M

L

I

H

K

FG

G J

K

A.18" (45.7 cm) upper side cabinet to countertop

B.13" (33 cm) max. upper cabinet depth

C.30" (76.2 cm) min. opening width

D.For minimum clearance to top of cooktop, see NOTE*.

E.30¹⁄₈" (76.5 cm) min. opening width

F. This shaded area recommended for installation of rigid gas pipe.

G. 8" (20.3 cm)

H. Grounded outlet I. 17" (43.2 cm)

J. 4¹⁄₂" (11.4 cm) K. 2" (5.1 cm)

L. 2" (5.1 cm) min. clearance from both sides of range to side wall or other combustible material.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

4

Image 4
Contents Table of Contents/Índice Range Safety Your safety and the safety of others are very importantTools and Parts Installation RequirementsLocation Requirements Cabinet Dimensions Product Dimensions Freestanding RangeMobile home installations require Gas Supply Requirements Installation Instructions Install Anti-Tip BracketLine pressure testing above ½ psi gauge 14 WCP Line pressure testing at ½ psi gauge 14 WCP or lowerMake Gas Connection Typical rigid pipe connectionVerify Anti-Tip Bracket Location Level RangeCheck Operation If the low flame needs adjusting Check Operation of Oven/Broil BurnerComplete Installation If the flame needs adjustingIf you need Assistance or Service GAS ConversionsTo Convert Surface Burners To Convert Gas Pressure RegulatorTo Convert Oven Burner Complete Conversion Pilot and Bypass Screws ConversionNatural Gas Conversion To Convert Surface Burners Pilot and Bypass Screws Conversion Seguridad DE LA Estufa Piezas y herramientas Requisitos DE InstalaciónRequisitos de ubicación Espacios libres para instalación Medidas del producto Estufa autónomaLas instalaciones en casas rodantes necesitan Requisitos del suministro de gas Tipo de gasLínea de suministro de gas Regulador de la presión de gasInstrucciones DE Instalación Desempaque la estufaInstalación del soporte anti-vuelco Prueba de presión del suministro de gasConexión del suministro de gas Nivelación de la estufa Verificación de la ubicación del soporte Anti-vuelcoVerifique el funcionamiento Verifique el funcionamiento del quemador de asar/del horno Si la llama baja necesita ajustarseComplete la instalación Si la llama necesita ajustarseSi necesita ayuda o servicio técnico Si la estufa no funciona, revise lo siguienteConversión de gas LP Conversiones DE GASCómo convertir el regulador de la presión del gas Cómo convertir los quemadores de superficie Conversión de tornillos de desvío y pilotoCómo convertir el quemador del horno Complete la conversión Conversión de gas naturalEspitas de los orificios Válvulas Obturador de aire W10121806C