Broan RM60000 manual Measure Installation, Prepare the Installation

Page 7

2. MEASURE INSTALLATION

Dimensions for the most common installation are shown below.

The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.

Distances over 30” are at the installer and users discretion.

 

 

Standard

 

 

8 ft. (2.44 m)

 

 

ceiling

Standard 18"

18"

 

(457 mm) H

(457 mm)

 

over-cooktop

19"

 

cabinet

(483 mm)

 

 

 

Top of wood

 

 

mounting strip

Hood

 

 

 

RMP Series

 

 

Backsplash

 

 

(optional)

 

24"

 

(610 mm)

 

 

 

Standard 36"

Cooktop

(914 mm)

H cooktop HH0028A

 

 

INSTALLATION WITH STANDARD 18’’ HIGH OVER-COOKTOP CABINET

3. PREPARE THE INSTALLATION

INSTALLATION WITH STANDARD

12’’ SOFFIT OR OPTIONAL

SOFFIT CHIMNEY RMN SERIES

Remove the installation kit from inside the hood.

Make sure that the following items are included:

-Wood strip

-Installation manual

-Accessories including:

Filters (Quantity varies depending on range hood width)

Bag of parts including:

(4)flat head screws #10-2’’, (8) screws #8 x 34’’, (4) nuts #10-32, (2) wall anchors, (2) washers 316’’ ID x 34’’ OD

Parts sold separately:

-Interior blower Model RM325H or RM326H (both include rough-in kit)

-In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)

-In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers

-Exterior blower assembly 331H, 332H, 335 or 336

-Halogen lights (120 V, 50 W, PAR 20)

-

Heat lamps (Infrared, 120 V, BR40, 250 W max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

RMP Series Backsplash (optional)

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-RBF Series Baffle filters (optional)

-Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 4 and 5 for a complete list of venting options

and model numbers.

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

Using a Phillips #2 or a Robertson #2 screwdriver, unscrew the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hood from the bottom of crate. Refer to figure beside to locate all

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 screws. Discard these screws and remove hood from wood pallet.

HR0002

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 7 -

Image 7
Contents RM60000 Series Never Pick UP a Flaming PAN-You may be burned To Reduce the Risk of a Range TOP Grease FireWarranty Model RM325H Model RM326HOptional Soffit Chimney RMN Series Series HoodRMP Series Model HLB3, HLB6, HLB9 or HLB11 Select Blower Option and Install DuctworkPrepare the Installation Measure InstallationInstallation with Standard 18’’ High OVER-COOKTOP Cabinet Install Transition to ROUGH-IN Plate Interior Blower only Install Backsplash OptionalInstall Wood Mounting Strip Install the HoodInstall the Blower Interior or Exterior Blower Install the ROUGH-IN Plate to the Hood ALL BlowersConnect the Wiring ALL Blowers Install the Optional Soffit ChimneyInstall Filters Install Light Bulbs and Warming LampsBaffle Filters USE and Care Operation QTY Hood Width Number Description Service PartsSérie RM60000 DE Cuisinière Afin DE Réduire LES Risques FEUGarantie Limitée DE UN AN DE BROAN-NUTONE Table DES MatièresFiltres À Chicane Modèle RM326HPlaque Ventilateur Hotte SérieRecouvrement de mur en acier COUVRE-CONDUIT Optionnel Série RMNFacultatif Modèle 331H, 332H, 335 OU Capuchon de toit Conduit rond De 10 po Ventilateur en ligneModèle HLB3, HLB6, HLB9 OU HLB11 Préparer L’INSTALLATION Mesurer L’INSTALLATIONInstallation Sous UNE Armoire Standard DE 18 PO DE Hauteur Choisir L’OPTION Ventilateur Intérieur OU Extérieur Installer LE Dosseret OptionnelInstaller LA Lisière DE Bois Installer LA HotteSérie RMN Optionnel Installer LE COUVRE-CONDUIT OptionnelInstaller LE Ventilateur Intérieur OU Extérieur Branchement Électrique Tous LES VentilateursInstaller LES Filtres Installer LES Ampoules ET Lampes ChauffantesFiltres à chicane Entretien Fonctionnement Pièce Description 17. Pièces DE RechangeSerie RM60000 Advertencia BROAN-NUTONE Garantía Limitada POR UN AÑO Índice DE MateriasModelo RM325H Ventilador Modelo RM326H VentiladorPlaca DEL Ventilador ventilador interior de 1200 pcm et Chimenea DE Intrados Opcional Serie RMN CampanaRemate de pared Ventilador exterior Redondo Modelo 331H, 332H, 335 O Seleccione LA Opción Ventilador Y Instale LOS ConductosModelo HLB3, HLB6, HLB9 O HLB11 Prepare LA Instalación Mida LA InstalaciónSeleccione LA Opción Ventilador Exterior O Interior Instale LA Placa Para Antisalpicaduras OpcionalInstalación DE LA Tira DE Madera Instale LA CampanaSerie RMN Opcional Conexión Eléctrica Todos LOS VentiladoresInstale LA Chimenea DE Intrados Opcional Instale EL Ventilador Interior O ExteriorInstale LOS Filtros Instale LOS Bombillas Y Lámparas TermógenaFiltros de zig zag Mantenimiento Funcionamiento CTD Anchura DE LA Campana Pieza Descripción Repuestos