Broan E55000 manual Operation, Halogen Bulbs, Controls, Heat Sentry

Page 4

OPERATION

 

 

 

 

 

 

 

 

 

 

 

LIGHT

 

 

BLOWER

 

 

 

 

 

SWITCH

 

MEDIUM

 

 

 

Controls

 

 

SPEED

 

 

 

 

 

 

 

 

 

BLOWER

 

 

 

 

 

 

 

BLOWER

 

The hood is operated using the (4) push-but-

 

 

 

 

 

 

 

 

 

HIGH

 

 

ON-LOW /

 

 

tons located at eye-level, on the front edge of

 

 

 

 

SPEED

 

 

 

 

OFF

 

 

the hood.

 

 

 

 

SWITCH

 

 

 

PILOT

The light switch turns the halogen lights on

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The blower on-low / off switch turns the blower on to its lowest running speed. The blower

must be turned on using this switch. Turn theFIG. 1 blower off by pressing this switch a second time.

The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.

The blower high speed switch changes the blower speed to high. This switch works only if the blower is already running at low or medium speed.

The pilot lamp lights up whenever the blower is on.

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

HALOGEN BULBS

This range hood requires two halogen bulbs (Type T3, 12Volt, 20Watt Max, G-4 Base).

WARNING: Always switch off the elec- trical supply before carrying out any op- eration on the appliance.

To change bulbs:

1.Open the cover by prying from the proper slots. Fig. 2.

2.Remove the bulb by pulling sideways. (DO NOT ROTATE).

CAUTION: Bulb may be hot.

FIG. 2

3.Replace with Type T3, 12Volt, 20 Watt Max, G-4 Base halogen bulb. Do not touch replacement bulb with bare hands!

CAUTION: Use of bulbs greater than 20 watts will cause the fuse to open.

- 4 -

Image 4
Contents Model E55000 English Français EspañolRead and Save These Instructions Intended for Domestic Cooking only WarningPage Operation Halogen BulbsControls Heat SentryFuse Replacement Maintenance Hood CleaningGrease Filter Non-ducted Recirculation FilterPrepare the Hood Install Electrical Install the DuctworkDucted and NON-DUCTED Hoods Install Mounting Bracket Framing BehindWood Cross Support Support BehindInstall Flue Mounting Bracket Ducted ConfigurationDucted and NON-DUCTED Hoods Mounting ScrewsFlue Mounting NON Ducted Hoods onlyFlat Head Bracket Screws Install HoodDucted NON Ducted HoodsRooms with 10-FOOT Ceilings Upper Flue VentsInstall Filters WarrantyBROAN-NUTONE LLC ONE Year Limited Warranty NON-DUCTED Hoods onlyPour Utilisation Domestique Seulement Avertissement AvertissementPage Commandes FonctionnementAmpoules Halogènes Heat SentrymcRemplacement DU Fusible Entretien Filtres à graissesFiltre à charbon Nettoyage de votre hottePréparation DE LA Hotte Installation Électrique Installation DU Système DE ConduitsConduit Décoratifcapuchon DE MUR Installation DU Support DE Montage Hauteur DU PlafondInstallation DU Support DE Montage DU Conduit Décoratif Hottes À ÉvacuationHottes À Recirculation DE LA Hotte InstallationHottes À Évacuation ET À Recirculation Avec Plafonds DE 10 PI ConduitGrilles DE SupérieurInstallation DES Filtres GarantieBlocage Garantie Limitée D’UN AN DE BROAN-NUTONE LLCLEA Y Conserve Estas Instrucciones AdvertenciaAdvertencia Funcionamiento Lamparas HalogenasMandos Heat SentrymrSustitución DEL Fusible Filtro al carbón configuración sin tubo MantenimientoFiltro antigrasa Limpieza de la campanaPrepare LA Campana Instalacion DEL Tubo DE Extraccion Sólo Campanas CON ConductoCON Conducto Y SIN Conducto Proceder a la conexión del cableadoInstalacion Soporte DE Montaje Marco Posterior DEL Apoyo Tranversal DE MaderaConfiguración CON Conducto Preparación DE LA CampanaTornillos DE DEL TuboConfiguración SIN Conducto Cabeza Plana DEL TuboLA Campana Instalación DECON Conducto Y SIN Salas CON Techos DE 10 Pies Respiraderos TuboSuperiores Superior OcultosConfiguración CON Conducto Y SIN Conducto Instalación DE FiltrosGarantia Garantia BROAN-NUTONE LLC POR UN AÑOModel E55000 Service PartsDescription Modele E55000 Liste Pieces DE RechangePart N Description Modelo E55000 Lista DE Piezas DE RecambioCÓD. N Pieza N Descripción 04307635