INSTALLATION

US and Canada

Model

Gas Type

Orifice Tip Size

Burner Pressure (in. W.C.)

Gross Input

 

 

 

 

 

SGC

Nat

#43

4.0

75kBtu

LP

#54

10.0

(22kW)

 

 

 

SG14

Nat

#41

4.0

110kBtu

LP

#53

10.0

(33kw)

 

 

 

SG14R

Nat

#38

4.0

122kBtu

LP

.062"

10.0

(36kW)

 

 

 

SG14T

Nat

#43

4.0

100kBtu

LP

1.45 mm

10.0

(30kW)

 

 

 

SG18

Nat

#41

4.0

140kBtu

LP

#53

10.0

(40kW)

 

 

 

SG6H

Nat

#41

4.0

140kBtu

LP

#53

10.0

(40kW)

 

 

 

MGII

Nat

#46

4.0

80kBtu

LP

#55

10.0

(23.4kW)

 

 

 

MGIIT

Nat

#46

4.0

80kBtu

LP

#55

10.0

(23.4kW)

 

 

 

SGH50

Nat

#46

4.0

80kBtu

LP

#55

10.0

(23.4kW)

 

 

 

SGH50T

Nat

#46

4.0

80kBtu

LP

#55

10.0

(23.4kW)

 

 

 

SGM18D4

Nat

#48

4.0

65kBtu

LP

#56

10.0

(19 kW)

 

SGM18D5

Nat

#48

4.0

85kBtu

LP

#56

10.0

(25 kW)

 

 

 

SGM1824

Nat

#40

4.0

120kBtu

LP

0.0625"

10.0

(35.0 kW)

 

SGM20

Nat

#48

4.0

85kBtu

LP

#56

10.0

(25 kW)

 

 

 

SGM24

Nat

#42

4.0

165kBtu

LP

1.45mm

10.0

(48.3kW)

 

SGM34

Nat

#42

4.0

210kBtu

LP

1.5 mm

10.0

(61.5 kW)

 

 

 

SSH55

Nat

#46

4.0

80 kBtu

LP

#55

10.0

(23.4kW)

 

 

 

SSH55T

Nat

#46

4.0

80 kBtu

LP

#55

10.0

(23.4 kW)

 

 

 

SSH55R

Nat

#43

4.0

100 kBtu

LP

1.45 mm

10.0

(29.3 kW)

 

 

 

SSH55TR

Nat

#43

4.0

100 kBtu

LP

1.45 mm

10.0

(29.3 kW)

 

 

 

SSH60

Nat

#46

4.0

80 kBtu

LP

#55

10.0

23.4 kW

 

SSH60R

Nat

#43

4.0

100 kBtu

LP

1.45 mm

10.0

(29.3 kW)

 

 

 

SSH60W

Nat

#46

4.0

100 kBtu

LP

#55

10.0

(29.3 kW)

 

SSH60WR

Nat

#43

4.0

125 kBtu

LP

1.45 mm

10.0

(36.6 kW)

 

 

 

SSH75

Nat

#45

4.0

105 kBtu

LP

1.35mm

10.0

(30.8 kW)

 

SSH75R

Nat

#43

4.0

125 kBtu

LP

1.45 mm

10.0

(36.6 kW)

 

 

 

Australia

Model

Gas Type

Orifice Tip Size

Burner Pressure

Gross Input

 

 

 

 

 

SGC

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SG14

Nat

2.4 mm

0.9

119 Mj/hr

LP

1.5 mm

2.5

 

 

SG14R

Nat

2.6 mm

0.9

129 Mj/hr

LP

.062"

2.5

 

 

SG14T

Nat

#44

0.9

100 Mj/hr

LP

#55

2.5

 

 

SG18

Nat

2.3 mm

0.9

145 Mj/hr

LP

1.5 mm

2.5

 

 

SG6H

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

MGII

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

MGIIT

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGH50

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGH50T

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGM18D4

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGM18D5

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGM1824

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

SGM20

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SGM24

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

SGM34

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SSH55

Nat

#46

1.0

88 Mj/hr

LP

#55

2.5

 

 

SSH55T

Nat

#46

1.0

88 Mj/hr

LP

#55

2.5

 

 

SSH55R

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SSH55TR

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SSH60

Nat

#46

1.0

88 Mj/hr

LP

#55

2.5

 

 

SSH60R

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SSH60W

Nat

#46

1.0

110

LP

#55

2.5

Mj/hr

 

SSH60WR

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

SSH75

Nat

#45

1.0

116

LP

1.35mm

2.5

Mj/hr

 

SSH75R

NOT APPROVED FOR USE IN THIS

 

COUNTRY

 

 

 

 

 

 

 

 

 

L20-378 rev. 0 (9/12)

13

Image 13
Contents English To the PURCHASER, Owner and Store Manager CE GAS Table not Applicable to ALL Models InstallationANNUAL/PERIODIC Preventative Maintenance and Inspection Boil OUT Procedure Temperature CheckBasket Lift Operation Additional Controller FunctionsTroubleshooting Installation Clearances InstallationHeat Deflector Installation if Equipped Checking Your NEW ApplianceLEG/CASTER Installation and Leveling Installation Setup Installation GAS ConnectionQuick Disconnect Connection Installation CE GAS Table not Applicable to ALL Models SGM20 G20 Overall Dimensions and Weights US and Canada Electrical Connections Ventilation and Fire Safety SystemsInspection Initial AdjustmentsDrain Valve Closed Filling the ApplianceON/OFF OFF Initial Cleaning Operational Features Preventative MaintenanceCook Tank Front Panel Preventative Maintenance Basic Operational FeaturesFilling the Tank with Liquid Shortening Filling the Cooker TankAppliance Start UP OIL TemperatureTemperatura DELL’OLIO Timer Operation Preventative Maintenance Θερμοκρασια ΛαδιουCooking SpinfreshtmAdditional Controller Functions Standby ModeCooking Tips Appliance ShutdownDaily Preventative Maintenance Preventative Maintenance Complete ShutdownFiltering with a Filter Drawer if Equipped Preventative Maintenance Flush Hose Operation if Equipped Preventative Maintenance Weekly Preventative Maintenance Preventative Maintenance Filter Cleaning if EquippedMonthly Preventative Maintenance Boil OUT ProcedureANNUAL/PERIODIC Preventative Maintenance and Inspection Ventilation Hood Mechanical InspectionPower Failure TroubleshootingHigh Temperature Limit Switch Drain Valve Interlock & Float Switch not on ALL ModelsTroubleshooting Fryer Troubleshooting Chart Troubleshooting ChartsFilter Troubleshooting Chart if Equipped DrainingDisplay Explanation Action Troubleshooting L20-378 rev 9/12

L20-378 specifications

The Pitco Frialator L20-378 is a highly regarded piece of commercial kitchen equipment, specifically designed for high-volume frying operations. Renowned for its efficiency and durability, the L20-378 meets the demands of busy restaurants, fast food chains, and catering operations that require consistent performance and outstanding results.

One of the standout features of the L20-378 is its impressive fry tank capacity. With a 40-pound oil capacity, it can handle a significant amount of product at once, allowing for simultaneous frying and the ability to serve large volumes quickly. This efficiency not only enhances productivity but also helps streamline kitchen operations during peak hours.

The L20-378 utilizes advanced heating technology known as "Heat exchanger" design. This technology maximizes heat transfer from the burners to the oil, ensuring that food cooks evenly and consistently. As a result, operators benefit from faster cooking times and exceptional product quality, with crispy exteriors and tender interiors.

Moreover, the unit's durable construction is a key characteristic. Built with stainless steel, the L20-378 is not only resistant to corrosion but also easy to clean and maintain. This durability extends the life of the fryer, making it a valuable investment for any kitchen. The fryer also features a convenient drain valve, enabling easy oil changing and maintenance, which is crucial for keeping the frying environment clean.

The L20-378 is equipped with user-friendly controls that allow for precise temperature settings and consistent frying results. This ease of use ensures that even less experienced staff can operate the fryer efficiently, minimizing the risk of mistakes during crucial cooking processes.

Another important aspect of the Pitco Frialator L20-378 is its safety features. These include built-in automatic temperature controls and high-limit protection to prevent overheating, contributing to a safer working environment. Additionally, the fryer is designed with a cool zone that helps catch food particles, reducing the likelihood of oil breakdown and extending the oil life.

In summary, the Pitco Frialator L20-378 is an exceptional fryer that combines large capacity, advanced heating technology, durable construction, and user-friendly controls. Its focus on efficiency and safety makes it a preferred choice for busy kitchens that demand reliable frying solutions capable of producing high-quality food consistently.